-
E-mail
15888188000@139.com
- Phone
-
Address
No. 223 North Binjiang Road, Yuyao City, Zhejiang Province
Zhejiang Jinyi Instrument Co., Ltd
15888188000@139.com
No. 223 North Binjiang Road, Yuyao City, Zhejiang Province
product details
The control function that comes with the device
Real time control: Real time control of the relevant equipment of the dynamometer.
Measurement and monitoring: Control the data measurement of the dynamometer equipment, record for a long time, analyze the data, display charts, etc.
Programmable output: According to the equipment's specifications, the output of the instrument device can be pre programmed and then controlled.
Data operation: Record the data recorded by the operating instrument.
Digital temperature indicator regulator
Developed according to the regulations of JJG 617-1996 Digital Temperature Indicator Regulator, detailed development is carried out based on technical requirements, calibration conditions, calibration items, calibration methods, result processing, etc. The interface is concise, the process is clear, and the report has custom functions. There are two calibration method modes: indication benchmark method and input benchmark method.
Analog temperature indicator regulator
Developed according to the regulations of JJG 951-2000 Analog Temperature Indicator Regulator, detailed development is carried out based on technical requirements, calibration conditions, calibration items, calibration methods, result processing, etc. The interface is concise, the process is clear, and the report has custom functions. There are two calibration method modes: full range indication and deviation indication.
Industrial process measurement recorder
Developed according to the regulations of JJG 74-2005 Industrial Process Measurement Recorder, detailed development is carried out based on technical requirements, calibration conditions, calibration items, calibration methods, result processing, etc. The interface is concise, the process is clear, and the report has custom functions. There are two verification methods: analog indication and digital indication.
temperature transmitter
Developed according to the JJF 1183-2007 Temperature Transmitter Calibration Specification, detailed development is carried out based on technical requirements, calibration conditions, calibration items, calibration methods, result processing, etc. The interface is concise, the process is clear, and the report has custom functions. Input signal and measurement signal selection, automatic range adaptation, automatic error calculation.