Main application areas
Suitable for signal quality judgment systems with fast sampling rates such as DCS and PLC, applied to units such as power, petrochemical, smelting, chemical, papermaking, etc. engaged in automated production.
Function Introduction
Slope output rate 10ms/time;
Three consecutive slope outputs can be set;
Three running times can be set;
It can program commonly used step signals and step interval time, and supports two modes: automatic step or manual step;
Supports three cold end temperature compensation methods: real-time temperature compensation using Pt100 temperature probe; Using fixed temperature values for constant temperature compensation; Real time temperature compensation using TC adapter box;
Multi functional and programmable unit conversion function, which can convert V, mA output or measurement into other engineering units;
When outputting mA signals, it supports two modes: mA source and analog transmitter;
When outputting and measuring thermocouple ℃ signals, display the corresponding mV value;
When outputting and measuring the thermal resistance ℃ signal, display the corresponding Ω value;
The temperature unit can be switched between ℃, ℉, and K;
When outputting Hz signals, the amplitude can be set and supports two modes: square wave or sine wave;
Provide 24V DC circuit power supply and measure the mA signal in the circuit;
Resistance and thermal resistance measurements support two/three/four wire wiring methods;
Support signal fine-tuning on any digit of the output value, used for calibration of pointer instruments;
Can lock or unlock measurement values during measurement;
When measuring numerical values, collect the minimum and maximum values and calculate the average value;
Can store on-site detection data and manage it using the data copying function of secondary instrument calibration software;
The display screen and keypad both have bright backlighting, making them suitable for use in low light environments;
Free downloads and upgrades
-Communication protocols and controls;
-Firmware software.
Main indicators
Output (one year, ambient temperature 20 ℃± 5 ℃) ★ represents the basic range gear
| output range | Maximum allowable error of 0.01 level | Maximum allowable error of 0.02 level | Maximum allowable error at level 0.05 | Resolution |
| 10.99999 V | ± (0.008% reading+0.0001 V) | ± (0.015% reading+0.0001 V) | ± (0.035% reading+0.0001 V) | 10μV |
| 1.099999 V ★ | ± (0.008% reading+0.00001 V) | ± (0.015% reading+0.00001 V) | ± (0.035% reading+0.00001 V) | 1μV |
|
– 99.9999 mV ~109.9999 mV |
± (0.008% reading+0.003 mV) | ± (0.015% reading+0.003 mV) | ± (0.035% reading+0.003 mV) | 1μV |
| 10 types of thermocouples ℃ | See "TC Thermocouple Technical Specifications" for details | See "TC Thermocouple Technical Specifications" for details | See "TC Thermocouple Technical Specifications" for details | 0.1℃ |
| 30.0999 mA ★ | ± (0.01% reading+1 μ A) | ± (0.015% reading+1 μ A) | ± (0.035% reading+1 μ A) | 0.1μA |
| 4000.00 Ω | ± (0.008% reading+0.04 Ω) | ± (0.015% reading+0.04 Ω) | ± (0.035% reading+0.04 Ω) | 10mΩ |
| 400.000 Ω ★ | ± (0.008% reading+0.005 Ω) | ± (0.015% reading+0.005 Ω) | ± (0.035% reading+0.005 Ω) | 1mΩ |
| 6 types of thermal resistors ℃ | Please refer to the "RTD Thermistor Technical Specifications" for details | Please refer to the "RTD Thermistor Technical Specifications" for details | Please refer to the "RTD Thermistor Technical Specifications" for details | 0.01℃ |
| 54999.9 Hz ★ | ± 2 Hz | ± 2 Hz | ± 2 Hz | 0.1Hz |
| 5499.99 Hz | ± 0.2 Hz | ± 0.2 Hz | ± 0.2 Hz | 0.01Hz |
| 549.999 Hz | ± 0.02 Hz | ± 0.02 Hz | ± 0.02 Hz | 0.001Hz |
| 24V DC circuit power supply | ± 5% | ± 5% | ± 5% | |
| Maximum output current of V: 10 mA; 20 mA output load capacity ≤ 1 K Ω; 50000 Hz load capacity ≥ 10 k Ω; Maximum output current of 24V DC circuit power supply: 80 mA Operating range of external excitation current for resistors and thermal resistors: 400 Ω/(0.5-7.5) mA; 4000Ω / (0.05~0.75)mA Frequency output waveform: symmetrical sine wave or positive 50% duty cycle square wave; Square wave peak value: (0.1-9.9) Vp-p; Sine wave peak to peak value: (0.2~19.8) Vp-p Amplitude accuracy: 2% reading+0.5% range | ||||
Measurement (one year, ambient temperature 20 ℃± 5 ℃) ★ represents the basic range range range
| Measurement range | Maximum allowable error of 0.01 level | Maximum allowable error of 0.02 level | Maximum allowable error at level 0.05 | Resolution |
| ± 59.9999 V | ± (0.008% reading+0.0005 V) | ± (0.015% reading+0.0005 V) | ± (0.035% reading+0.0005 V) | 0.1mV |
| ± 5.99999 V ★ | ± (0.008% reading+0.00005 V) | ± (0.015% reading+0.00005 V) | ± (0.035% reading+0.00005 V) | 0.01mV |
| ± 599.999 mV | ± (0.008% reading+0.005 mV) | ± (0.015% reading+0.005 mV) | ± (0.035% reading+0.005 mV) | 1μV |
| ± 119.999 mV | ± (0.008% reading+0.003 mV) | ± (0.015% reading+0.003 mV) | ± (0.035% reading+0.003 mV) | 1μV |
| 10 types of thermocouples ℃ | See "TC Thermocouple Technical Specifications" for details | See "TC Thermocouple Technical Specifications" for details | See "TC Thermocouple Technical Specifications" for details | 0.1℃ |
| ± 119.999 mA | ± (0.01% reading+1 μ A) | ± (0.015% reading+1 μ A) | ± (0.035% reading+1 μ A) | 1μA |
| ± 23.9999 mA ★ | ± (0.01% reading+1 μ A) | ± (0.015% reading+1 μ A) | ± (0.035% reading+1 μ A) | 0.1μA |
| 5999.99 Ω | ± (0.008% reading+0.05 Ω) | ± (0.015% reading+0.05 Ω) | ± (0.035% reading+0.05 Ω) | 10mΩ |
| 599.999 Ω ★ | ± (0.008% reading+0.005 Ω) | ± (0.015% reading+0.005 Ω) | ± (0.035% reading+0.005 Ω) | 1mΩ |
| 6 types of thermal resistors ℃ | Please refer to the "RTD Thermistor Technical Specifications" for details | Please refer to the "RTD Thermistor Technical Specifications" for details | Please refer to the "RTD Thermistor Technical Specifications" for details | 0.01℃ |
| 59999.9 Hz ★ | ± 2 Hz | ± 2 Hz | ± 2 Hz | 0.1Hz |
| 9999.99 Hz | ± 0.4 Hz | ± 0.4 Hz | ± 0.4 Hz | 0.01Hz |
| 999.999 Hz | ± 0.04 Hz | ± 0.04 Hz | ± 0.04 Hz | 0.001Hz |
|
50 V measurement input impedance ≥ 1 M Ω; 5 V measurement input impedance ≥ 500 M Ω; current measurement input impedance ≤ 10 Ω; Hz measurement input impedance ≥ 1 M Ω Resistance and thermal resistance measurement current: 500 Ω/1 mA; 5000 Ω/0.5 mA 1 Hz~100Hz:0.2 V~250 V(rms); 100 Hz~10 KHz:0.25 V~30 V(rms); 10 KHz~59 KHz:0.5 V~30 V(rms) Preheating time: 30 minutes; Working temperature: -10 ℃ to+50 ℃; Relative humidity: 0-90% RH; Storage temperature: -20 ℃ -+60 ℃ Temperature coefficient: ± (0.0002% reading+0.0002% range)/℃ (<15 ℃ or>25 ℃) | ||||
RTD thermistor (one year, ambient temperature: 20 ℃± 5 ℃)
| Thermal resistance index number | temperature range | Maximum allowable error (analog output) | Maximum allowable error (measurement) | ||||
| 0.01 level | 0.02 level | 0.05 level | 0.01 level | 0.02 level | 0.05 level | ||
| Pt100 | (– 200~0)℃ | ± 0.05℃ | ± 0.07℃ | ± 0.12℃ | ± 0.05℃ | ± 0.07℃ | ± 0.12℃ |
| (0~400)℃ | ± 0.09℃ | ± 0.20℃ | ± 0.28℃ | ± 0.09℃ | ± 0.14℃ | ± 0.28℃ | |
| (400~600)℃ | ± 0.11℃ | ± 0.20℃ | ± 0.37℃ | ± 0.11℃ | ± 0.18℃ | ± 0.37℃ | |
| (600~850)℃ | ± 0.14℃ | ± 0.30℃ | ± 0.50℃ | ± 0.14℃ | ± 0.23℃ | ± 0.50℃ | |
| Pt1000 | (– 200~0)℃ | ± 0.05℃ | ± 0.10℃ | ± 0.11℃ | ± 0.05℃ | ± 0.07℃ | ± 0.12℃ |
| (0~400)℃ | ± 0.08℃ | ± 0.13℃ | ± 0.28℃ | ± 0.09℃ | ± 0.14℃ | ± 0.28℃ | |
| (400~600)℃ | ± 0.11℃ | ± 0.17℃ | ± 0.37℃ | ± 0.11℃ | ± 0.18℃ | ± 0.37℃ | |
| (600~850)℃ | ± 0.14℃ | ± 0.23℃ | ± 0.50℃ | ± 0.14℃ | ± 0.23℃ | ± 0.50℃ | |
| Cu50 | (– 50~150)℃ | ± 0.07℃ | ± 0.10℃ | ± 0.17℃ | ± 0.07℃ | ± 0.10℃ | ± 0.17℃ |
| BA1 | (– 200~0)℃ | ± 0.06℃ | ± 0.08℃ | ± 0.13℃ | ± 0.06℃ | ± 0.08℃ | ± 0.13℃ |
| (0~400)℃ | ± 0.10℃ | ± 0.15℃ | ± 0.30℃ | ± 0.10℃ | ± 0.15℃ | ± 0.30℃ | |
| (400~650)℃ | ± 0.13℃ | ± 0.20℃ | ± 0.41℃ | ± 0.13℃ | ± 0.20℃ | ± 0.41℃ | |
| BA3 | (– 50~100)℃ | ± 0.08℃ | ± 0.10℃ | ± 0.18℃ | ± 0.05℃ | ± 0.07℃ | ± 0.15℃ |
| G | (– 50~150)℃ | ± 0.07℃ | ± 0.09℃ | ± 0.17℃ | ± 0.07℃ | ± 0.09℃ | ± 0.17℃ |
Note: ① It conforms to the 90 international temperature scale and is determined by the maximum allowable error of resistance output and measurement.
TC thermocouple (one year, ambient temperature: 20 ℃± 5 ℃)
| Thermocouple division number | temperature range | Maximum allowable error (analog output and measurement) | ||
| 0.01 level | 0.02 level | 0.05 level | ||
| S | (– 20~200)℃ | ± 0.9℃ | ± 0.9℃ | ± 0.9℃ |
| (200~700)℃ | ± 0.5℃ | ± 0.5℃ | ± 0.6℃ | |
| (700~1500)℃ | ± 0.5℃ | ± 0.6℃ | ± 0.8℃ | |
| (1500~1768)℃ | ± 0.5℃ | ± 0.6℃ | ± 1.0℃ | |
| R | (– 20~100)℃ | ± 0.9℃ | ± 0.9℃ | ± 0.9℃ |
| (100~600)℃ | ± 0.6℃ | ± 0.6℃ | ± 0.6℃ | |
| (600~1600)℃ | ± 0.4℃ | ± 0.5℃ | ± 0.8℃ | |
| (1600~1768)℃ | ± 0.5℃ | ± 0.6℃ | ± 1.0℃ | |
| J | (– 210~– 100)℃ | ± 0.3℃ | ± 0.3℃ | ± 0.4℃ |
| (– 100~300)℃ | ± 0.2℃ | ± 0.2℃ | ± 0.2℃ | |
| (300~900)℃ | ± 0.2℃ | ± 0.2℃ | ± 0.4℃ | |
| (900~1200)℃ | ± 0.2℃ | ± 0.3℃ | ± 0.5℃ | |
| K | (– 250~–150)℃ | ± 1.0℃ | ± 1.1℃ | ± 1.3℃ |
| (–150~1000)℃ | ± 0.2℃ | ± 0.3℃ | ± 0.5℃ | |
| (1000~1372)℃ | ± 0.3℃ | ± 0.4℃ | ± 0.7℃ | |
| T | (– 250~–200)℃ | ± 0.8℃ | ± 0.8℃ | ± 1.0℃ |
| (–200~0)℃ | ± 0.3℃ | ± 0.4℃ | ± 0.4℃ | |
| (0~400)℃ | ± 0.2℃ | ± 0.2℃ | ± 0.2℃ | |
| N | (– 200~– 100)℃ | ± 0.5℃ | ± 0.5℃ | ± 0.6℃ |
| (–100~600)℃ | ± 0.3℃ | ± 0.3℃ | ± 0.3℃ | |
| (600~1300)℃ | ± 0.3℃ | ± 0.4℃ | ± 0.6℃ | |
| E | (– 250~–200)℃ | ± 0.5℃ | ± 0.6℃ | ± 0.8℃ |
| (–200~700)℃ | ± 0.2℃ | ± 0.3℃ | ± 0.3℃ | |
| (700~1000)℃ | ± 0.2℃ | ± 0.3℃ | ± 0.5℃ | |
| B | (600~800)℃ | ± 0.8℃ | ± 0.8℃ | ± 0.9℃ |
| (800~1100)℃ | ± 0.6℃ | ± 0.6℃ | ± 0.7℃ | |
| (1100~1820)℃ | ± 0.5℃ | ± 0.6℃ | ± 0.8℃ | |
| WRe3-25 | (0~1800)℃ | ± 0.5℃ | ± 0.6℃ | ± 1.0℃ |
| (1800~2200)℃ | ± 0.7℃ | ± 0.9℃ | ± 1.6℃ | |
| (2200~2315)℃ | ± 0.8℃ | ± 1.2℃ | ± 2.0℃ | |
| WRe5-26 | (0~1000)℃ | ± 0.3℃ | ± 0.4℃ | ± 0.6℃ |
| (1000~1800)℃ | ± 0.5℃ | ± 0.7℃ | ± 1.1℃ | |
| (1800~2315)℃ | ± 0.8℃ | ± 1.1℃ | ± 1.9℃ | |
Note:① Compliant with the 90 international temperature scale, determined by the maximum allowable error of mV output and measurement;
② Excluding sensor and compensation wire errors;
③ Accuracy with external cold contacts, adding 0.2 ℃ for internal contacts;
④ The maximum allowable error of Pt100 temperature probe is ± 0.20 ℃.
Other indicators
| project | specifications | |
| Warm-up time | After 5 minutes of startup, the technical specifications are met | |
| Electrical measurement connection | 4mm gold-plated lantern plug | |
| Side port connection | Pressure/24V DC Temperature measurement/switch HART/RS232 connection |
Aviation plug |
| Charger connection | φ (5.5 × 2.5) mm DC port | |
| External dimensions | (205x110x52)mm | |
| weight | About 0.9kg | |
| display | 3.7-inch monochrome dot matrix LCD display screen | |
| Display Contrast | adjustable | |
| Button backlight | LED, closable | |
| Battery Category Capacity | Lithium battery pack 7.4V/4800mAh, 36Wh | |
| Battery life | Charge and discharge more than 300 times | |
| Battery charging time | About 4 hours | |
| battery life | 12 hours (measurement and output, turn on circuit power 12mA, screen and button backlight on); >15 hours (measurement and output, screen and button backlight on); 16 hours (measurement or output, screen and button backlight on, continuous). |
|
| Adapter input | (100-240)V AC,(50-60)Hz | |
| Adapter output | 8.6V DC/1A | |
| operation temperature | (-10~50)°C | |
| storage temperature | (-20~60)°C | |
| Maximum relative humidity without condensation | 90% at 35 ° C; At 75% and 40 ° C; 45% at 50 ° C. |
|
optional function
Secondary instrument calibration software
-National metrological verification regulations with multiple instruments, unified management of relevant information of the tested instruments;
-Automatically execute the calibration process, analyze data, and generate calibration certificates (calibration reports) and other reports;
-Can import custom report templates (Excel documents) and manage reports and templates uniformly according to customer verification requirements;
-The on-site detection data stored in the calibrator can be uniformly managed for data copying, editing, storage, printing, etc;
-The calibrator can be operated remotely through a computer, and can perform signal source output or signal acquisition work for a long time, while managing corresponding data;
-Provides signal conversion tools for 10 types of thermocouples and 8 types of thermal resistors.