JY951 Multi Channel Automatic Control System Calibrator

NegotiableUpdate on 11/13
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Product Overview: Fully isolated 12 channel, capable of simultaneously outputting and measuring voltage, current, resistance, frequency, pulse, etc TC、RTD, Flexible configuration of output/measurement modules. Networking multiple calibrators can achieve overall performance testing of DCS systems. Calibration equipment: DCS, PLC, AO/AI card, temperature inspection instrument, multi-channel data acquisition instrument, ordinary temperature transmitter, thermocouple and thermal resistance thermometer, data recorder, tachometer, vortex flowmeter, counter, etc. Main features: * Freely detachable drawer style module, supporting diversified combination forms; *Flexible configuration of output/measurement modules; *Support multiple calibrators networking, up to 3000 channels.

Product Details

Product Details

Feature Overview

  • Collaborate with software support to conduct overall performance testing on DCS/PLC control systems;

  • Can serve as a hardware platform for periodic testing of important protection systems;

  • Multiple channels of the device can be synchronously calibrated (such as AO/AI cards, temperature inspection instruments, and multi-channel data acquisition/recording devices) to improve work efficiency;

  • High response rate: The response time of a single module from computer instructions to the module is less than 3 milliseconds;

  • When simulating thermocouple output, the cold junction temperature can be automatically compensated;

  • Provide three communication methods: USB, Ethernet TCP, RS232

  • Provide communication protocols and underlying driver modules;

  • Provide testing, real-time, and instruction demonstration tool software.

  • According to the requirements, the upper computer software can be customized.


safe and reliable

  • The output port can withstand 36V DC ingress;

  • output portallShort circuit self recovery is possible.


Key Metrics

Output (one year, ambient temperature 20 ℃± 5 ℃) ★ represents the basic range gear

range Maximum allowable error of 0.01 level Maximum allowable error of 0.02 level resolution
± 10.99999 V ± (0.008% reading+0.0001 V) ± (0.015% reading+0.0001 V) 0.01 mV
± 1.099999 V ± (0.008% reading+0.00001 V) ± (0.015% reading+0.00001 V) 1 μV
± 109.9999 mV ± (0.008% reading+0.003 mV) ± (0.015% reading+0.003 mV) 1 μV
8 types of thermocouples ℃ See "TC Thermocouple Technical Specifications" for details See "TC Thermocouple Technical Specifications" for details 0.1 ℃
25.0000 mA ± (0.01% reading+1 μ A) ± (0.015% reading+1 μ A) 0.1 μA
4000.00 Ω ± (0.008% reading+0.04 Ω) ± (0.015% reading+0.04 Ω) 10 mΩ
400,000 Ω ± (0.008% reading+0.005 Ω) ± (0.015% reading+0.005 Ω) 1 mΩ
6 types of thermal resistors ℃ Please refer to the "RTD Thermistor Technical Specifications" for details Please refer to the "RTD Thermistor Technical Specifications" for details 0.01 ℃
54999.9 Hz ± 2 Hz ± 2 Hz 0.1 Hz
999999 pulses ± 1 piece ± 1 piece 1 piece

Maximum output current of V: 10 mA; MA output load capacity ≤ 1 k Ω; 50000 Hz load capacity ≥ 10 k Ω;

Waveform: square wave, amplitude: (0.1-9.9) Vp-p; Resistance output external excitation current range: 400 Ω/(0.5-7.5) mA; 4000 Ω/(0.05-0.75) mA.


Measurement (one year, ambient temperature 20 ℃± 5 ℃) ★ represents the basic range range range

range Maximum allowable error of 0.01 level Maximum allowable error of 0.02 level resolution
± 10.99999 V ± (0.008% reading+0.0001 V) ± (0.015% reading+0.0001 V) 0.01 mV
± 23.9999 mA ± (0.01% reading+1 μ A) ± (0.01% reading+1 μ A) 0.1 μA
10 V measurement input impedance: ≥ 1 M Ω; current measurement input impedance: ≤ 10 Ω.


RTD thermistor (one year, ambient temperature: 20 ℃± 5 ℃)

Thermal resistance index number temperature range Maximum allowable error (analog output)
0.01 level 0.02 level
Pt100 (– 200~0)℃ ± 0.05℃ ± 0.07℃
( 0~400)℃ ± 0.09℃ ± 0.20℃
(400~600)℃ ± 0.11℃ ± 0.20℃
(600~850)℃ ± 0.14℃ ± 0.30℃
Pt1000 (– 200~0)℃ ± 0.05℃ ± 0.10℃
(0~400)℃ ± 0.08℃ ± 0.13℃
(400~600)℃ ± 0.11℃ ± 0.17℃
(600~850)℃ ± 0.14℃ ± 0.23℃
Cu50 (– 50~150)℃ ± 0.07℃ ± 0.10℃
BA1 (– 200~0)℃ ± 0.06℃ ± 0.08℃
( 0~400)℃ ± 0.10℃ ± 0.15℃
(400~650)℃ ± 0.13℃ ± 0.20℃
BA3 (– 50~100)℃ ± 0.08℃ ± 0.10℃
G (– 50~150)℃ ± 0.07℃ ± 0.09℃


TC thermocouple (one year, ambient temperature: 20 ℃± 5 ℃)

Thermocouple division number temperature range Maximum allowable error (analog output)
0.01 level 0.02 level
S (– 20~200)℃ ± 0.9℃ ± 0.9℃
(200~700)℃ ± 0.5℃ ± 0.5℃
(700~1500)℃ ± 0.5℃ ± 0.6℃
(1500~1768)℃ ± 0.5℃ ± 0.6℃
R (– 20~100)℃ ± 0.9℃ ± 0.9℃
(100~600)℃ ± 0.6℃ ± 0.6℃
(600~1600)℃ ± 0.4℃ ± 0.5℃
(1600~1768)℃ ± 0.5℃ ± 0.6℃
J (– 210~– 100)℃ ± 0.3℃ ± 0.3℃
(– 100~300)℃ ± 0.2℃ ± 0.2℃
(300~900)℃ ± 0.2℃ ± 0.2℃
(900~1200)℃ ± 0.2℃ ± 0.3℃
K (– 250~–150)℃ ± 1.0℃ ± 1.1℃
(– 150~1000)℃ ± 0.2℃ ± 0.3℃
(1000~1372)℃ ± 0.3℃ ± 0.4℃
T (– 250~–200)℃ ± 0.8℃ ± 0.8℃
(– 200~0)℃ ± 0.3℃ ± 0.4℃
(0~400)℃ ± 0.2℃ ± 0.2℃
N (– 200~– 100)℃ ± 0.5℃ ± 0.5℃
(– 100~600)℃ ± 0.3℃ ± 0.3℃
(600~1300)℃ ± 0.3℃ ± 0.4℃
E (– 250~–200)℃ ± 0.5℃ ± 0.6℃
(– 200~700)℃ ± 0.2℃ ± 0.3℃
(700~1000)℃ ± 0.2℃ ± 0.3℃
B (600~800)℃ ± 0.8℃ ± 0.8℃
(800~1100)℃ ± 0.6℃ ± 0.6℃
(1100~1820)℃ ± 0.5℃ ± 0.6℃

Note: ①comply withThe 90 international temperature scale is determined by the maximum allowable error of mV output and measurement;

Excluding sensor and compensating wire errors.


Other indicators

project Specifications
Automatic temperature compensation range (0~50)℃
Electrical measurement connection 4mm gold-plated lantern plug
communication connection Ethernet port USB
Synchronize trigger port DB37
Overall dimensions (485×177×430)mm
weight 10kg (host); 0.25kg (module)
power supply voltage AC 220V±10%,50Hz
power consumption 20W
Operating Temperature (0~50)℃
Storage temperature (–20~60)℃
Relative humidity (maximum, no condensation) At 90% and 35 ℃;
At 75% and 40 ℃;
45% at 50 ℃.