The control function that comes with the device
Calibration task: After purchasing the calibration task for JY87X and JY86X, this software will automatically enable this function, which can export the calibration task data of the device, perform appropriate data refinement, and export it as a report.
Real time control: Real time control of related equipment of the dynamometer.
Measurement and monitoring: Control the data measurement of the dynamometer equipment, record for a long time, analyze the data, display charts, etc.
Programmable output: According to the equipment's specifications, the output of the instrument device can be pre programmed and then controlled.
Notebook: JY87X, JY86X After purchasing the notebook, this software will automatically enable this function and export the calibration task data of the device.
Data logger: JY87X and JY86X. After purchasing a recorder, this software will automatically enable this function and export the calibration task data of the device.
Digital temperature indicator regulator
Developed according to the regulations of JJG 617-1996 Digital Temperature Indicator Regulator, detailed development is carried out based on technical requirements, calibration conditions, calibration items, calibration methods, result processing, etc. The interface is concise, the process is clear, and the report has custom functions. There are two calibration method modes: indication benchmark method and input benchmark method.
Analog temperature indicator regulator
Developed according to the regulations of JJG 951-2000 Analog Temperature Indicator Regulator, detailed development is carried out based on technical requirements, calibration conditions, calibration items, calibration methods, result processing, etc. The interface is concise, the process is clear, and the report has custom functions. There are two calibration method modes: full range indication and deviation indication.
Industrial process measurement recorder
Developed according to the regulations of JJG 74-2005 Industrial Process Measurement Recorder, detailed development is carried out based on technical requirements, calibration conditions, calibration items, calibration methods, result processing, etc. The interface is concise, the process is clear, and the report has custom functions. There are two verification methods: analog indication and digital indication.
Temperature Transmitter
Developed according to the JJF 1183-2007 Temperature Transmitter Calibration Specification, detailed development is carried out based on technical requirements, calibration conditions, calibration items, calibration methods, result processing, etc. The interface is concise, the process is clear, and the report has custom functions. Input signal and measurement signal selection, automatic range adaptation, automatic error calculation.
Flow integrator
Developed according to the "JJG 1003-2016 Verification Regulations for Flow Accumulators", detailed development is carried out based on the technical requirements, verification conditions, verification items, verification methods, result processing, and other requirements of the regulations. The interface is concise, the process is clear, and the report has custom functions. This system can meet the verification/calibration requirements of flow integrators with an accuracy level of 0.1% or below, and can perform instantaneous flow, cumulative flow, cumulative heat, compensation parameters, and current output verification according to the verification regulations of JJG 1003-2016 Flow Accumulators. This system is capable of verifying steam substance parameters (density, specific volume, specific enthalpy, specific entropy, sound velocity, isentropic index, viscosity) that comply with GB/T 34060; Can verify natural gas physical parameters (density, molar mass, molar density, compressibility factor, relative density, gasification rate, high/low calorific value, Wopo index) that comply with GB/T 17747, ISO 12213-2, and GB/T 11062. The system has strong adaptability and can meet the calibration work of various flow calculation instruments.
pressure gauge
Developed according to the "JJG 52-2013 Verification Regulations for General Pressure Gauge, Pressure Vacuum Gauge and Vacuum Gauge of Elastic Components" and "JJG 49-2013 Verification Regulations for Precision Pressure Gauge and Vacuum Gauge of Elastic Components", detailed development is carried out based on the technical requirements, verification conditions, verification items, verification methods, result processing and other requirements of the regulations. The interface is concise, the process is clear, and the report has custom functions.
pressure gauge
Developed according to the "JJG 875-2005 Digital Pressure Gauge" regulation, detailed development is carried out based on the technical requirements, calibration conditions, calibration items, calibration methods, result processing, and other requirements of the regulation. The interface is concise, the process is clear, and the report has custom functions.
Pressure transmitter
Developed according to the "JJG 882-2015 Pressure Transmitter Calibration Regulations", detailed development is carried out based on the technical requirements, calibration conditions, calibration items, calibration methods, result processing, and other requirements of the regulations. The interface is concise, the process is clear, and the report has custom functions. Automatically adapt to range and calculate errors.
pressure controller
Developed according to the "JJG 544-2011 Pressure Controller Calibration Regulations", detailed development is carried out based on the technical requirements, calibration conditions, calibration items, calibration methods, result processing, and other requirements of the regulations. The interface is concise, the process is clear, and the report has custom functions.
Common tools