JY824 JY823 JY822 JY821 JY820 JY810 Multi functional Process Verification Instrument

NegotiableUpdate on 06/20
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Product Overview: Fully isolated dual channel, capable of simultaneously outputting and measuring voltage, current, resistance, frequency, etc TC、RTD, Provide independent 24V DC power supply. Cooperate with JY7000 digital pressure module to complete pressure calibration and precision measurement. Calibration equipment: ordinary temperature and pressure transmitters, thermocouples and thermal resistance thermometers, data recorders, tachometers, vortex flowmeters, pressure gauges, pressure switches, JY824 supports HART intelligent temperature and pressure transmitters, etc. Main features: * Won the invention patent "Low Impedance Current Limiting Anti High Voltage Protection Circuit", the output and measurement ports can withstand 250V AC accidental entry, and the super strong protection circuit prevents damage to the instrument caused by misoperation; *Awarded the invention patent "Numerical Control Variable Resistance Device", the response rate of the resistance output is faster and more stable; *24V DC power supply with a maximum load current of 80mA; * Powerful intelligent management software that automatically and efficiently collects and reports calibration data, making the calibration process easier.

Product Details

product details

Function Introduction

  • JY824 is an adjustable HART instrument with a built-in 250 Ω resistor, which is powerful and easy to use;

  • It can program commonly used step signals and step interval time, and supports two modes: automatic step or manual step;

  • Supports three cold end temperature compensation methods: real-time temperature compensation using Pt100 temperature probe; Using fixed temperature values for constant temperature compensation; Real time temperature compensation using TC adapter box;

  • Multi functional and programmable unit conversion function, which can convert V, mA output or measurement into other engineering units;

  • When outputting mA signals, it supports two modes: mA source and analog transmitter;

  • When outputting and measuring thermocouple ℃ signals, display the corresponding mV value;

  • When outputting and measuring the thermal resistance ℃ signal, display the corresponding Ω value;

  • The temperature unit can be switched between ℃, ℉, and K;

  • When outputting Hz signals, the amplitude can be set and supports two modes: square wave or sine wave;

  • Provide 24V DC circuit power supply and measure the mA signal in the circuit;

  • Resistance and thermal resistance measurements support two/three/four wire wiring methods;

  • Support signal fine-tuning on any digit of the output value, used for calibration of pointer instruments;

  • Can lock or unlock measurement values during measurement;

  • When measuring numerical values, collect the minimum and maximum values and calculate the average value;

  • Can store on-site detection data and manage it using the data copying function of secondary instrument calibration software;

  • The display screen and keypad both have bright backlighting, making them suitable for use in low light environments;

  • Free downloads and upgrades

-Communication protocols and controls;

-Firmware software.


Accurate and stable

  • Small temperature drift: ± (0.0002% reading+0.0002% range)/℃;

  • Small time drift: ± (0.004% reading+0.001% range)/year;

  • Low voltage noise: 1 × 10-5Range;

  • Low current noise: 1 × 10-5Range;

  • Strong resistance to various interferences;

  • Original 24K gold-plated low thermoelectric potential material, with more stable signal.


Safe and reliable

  • Both the output and measurement ports can withstand 250V AC ingress;

  • Both the output port and 24V DC port can automatically recover from short circuits;

  • The measurement channels are all automatic range;

  • The charging system has automatic safety protection such as overcharging, overdischarging, and short circuit;

  • The shell has high insulation strength and strong seismic and drop resistance.


Main indicators

Output (one year, ambient temperature 20 ℃± 5 ℃) ★ represents the basic range gear

output range Maximum allowable error of 0.01 level Maximum allowable error of 0.02 level Maximum allowable error at level 0.05 Resolution
10.99999 V ± (0.008% reading+0.0001 V) ± (0.015% reading+0.0001 V) ± (0.035% reading+0.0001 V) 10μV
1.099999 V ★ ± (0.008% reading+0.00001 V) ± (0.015% reading+0.00001 V) ± (0.035% reading+0.00001 V) 1μV
– 99.9999 mV
~109.9999 mV
± (0.008% reading+0.003 mV) ± (0.015% reading+0.003 mV) ± (0.035% reading+0.003 mV) 1μV
10 types of thermocouples ℃ See "TC Thermocouple Technical Specifications" for details See "TC Thermocouple Technical Specifications" for details See "TC Thermocouple Technical Specifications" for details 0.1℃
30.0999 mA ★ ± (0.01% reading+1 μ A) ± (0.015% reading+1 μ A) ± (0.035% reading+1 μ A) 0.1μA
4000.00 Ω ± (0.008% reading+0.04 Ω) ± (0.015% reading+0.04 Ω) ± (0.035% reading+0.04 Ω) 10mΩ
400.000 Ω ★ ± (0.008% reading+0.005 Ω) ± (0.015% reading+0.005 Ω) ± (0.035% reading+0.005 Ω) 1mΩ
6 types of thermal resistors ℃ Please refer to the "RTD Thermistor Technical Specifications" for details Please refer to the "RTD Thermistor Technical Specifications" for details Please refer to the "RTD Thermistor Technical Specifications" for details 0.01℃
54999.9 Hz ★ ± 2 Hz ± 2 Hz ± 2 Hz 0.1Hz
5499.99 Hz ± 0.2 Hz ± 0.2 Hz ± 0.2 Hz 0.01Hz
549.999 Hz ± 0.02 Hz ± 0.02 Hz ± 0.02 Hz 0.001Hz
24V DC circuit power supply ± 5% ± 5% ± 5%
Maximum output current of V: 10 mA; 20 mA output load capacity ≤ 1 k Ω; 50000 Hz load capacity ≥ 10 k Ω; Maximum output current of 24V DC circuit power supply: 80 mA
Operating range of external excitation current for resistors and thermal resistors: 400 Ω/(0.5-7.5) mA; 4000Ω / (0.05~0.75)mA
Frequency output waveform: symmetrical sine wave or positive 50% duty cycle square wave; Square wave peak value: (0.1-9.9) Vp-p; Sine wave peak to peak value: (0.2~19.8) Vp-p
Amplitude accuracy: 2% reading+0.5% range


Measurement (one year, ambient temperature 20 ℃± 5 ℃) ★ represents the basic range range range

Measurement range Maximum allowable error of 0.01 level Maximum allowable error of 0.02 level Maximum allowable error at level 0.05 Resolution
± 59.9999 V ± (0.008% reading+0.0005 V) ± (0.015% reading+0.0005 V) ± (0.035% reading+0.0005 V) 0.1mV
± 5.99999 V ★ ± (0.008% reading+0.00005 V) ± (0.015% reading+0.00005 V) ± (0.035% reading+0.00005 V) 0.01mV
± 599.999 mV ± (0.008% reading+0.005 mV) ± (0.015% reading+0.005 mV) ± (0.035% reading+0.005 mV) 1μV
± 119.999 mV ± (0.008% reading+0.003 mV) ± (0.015% reading+0.003 mV) ± (0.035% reading+0.003 mV) 1μV
10 types of thermocouples ℃ See "TC Thermocouple Technical Specifications" for details See "TC Thermocouple Technical Specifications" for details See "TC Thermocouple Technical Specifications" for details 0.1℃
± 119.999 mA ± (0.01% reading+1 μ A) ± (0.015% reading+1 μ A) ± (0.035% reading+1 μ A) 1μA
± 23.9999 mA ★ ± (0.01% reading+1 μ A) ± (0.015% reading+1 μ A) ± (0.035% reading+1 μ A) 0.1μA
5999.99 Ω ± (0.008% reading+0.05 Ω) ± (0.015% reading+0.05 Ω) ± (0.035% reading+0.05 Ω) 10mΩ
599.999 Ω ★ ± (0.008% reading+0.005 Ω) ± (0.015% reading+0.005 Ω) ± (0.035% reading+0.005 Ω) 1mΩ
6 types of thermal resistors ℃ Please refer to the "RTD Thermistor Technical Specifications" for details Please refer to the "RTD Thermistor Technical Specifications" for details Please refer to the "RTD Thermistor Technical Specifications" for details 0.01℃
59999.9 Hz ★ ± 2 Hz ± 2 Hz ± 2 Hz 0.1Hz
9999.99 Hz ± 0.4 Hz ± 0.4 Hz ± 0.4 Hz 0.01Hz
999.999 Hz ± 0.04 Hz ± 0.04 Hz ± 0.04 Hz 0.001Hz
50 V measured input impedance: ≥ 1 M Ω; 5 V measured input impedance ≥ 500 M Ω; current measured input impedance ≤ 10 Ω; Hz measurement input impedance ≥ 1 M Ω
Resistance and thermal resistance measurement current: 500 Ω/1 mA; 5000 Ω/0.5 mA
1 Hz~100 Hz:0.2 V~250 V(rms); 100 Hz~10 kHz:0.25 V~30 V(rms); 10 kHz~59 kHz:0.5 V~30 V(rms)
Preheating time: 30 minutes; Working temperature: -10 ℃ to+50 ℃; Relative humidity: 0-90% RH; Storage temperature: -20 ℃ -+60 ℃
Temperature coefficient: ± (0.0002% reading+0.0002% range)/℃ (<15 ℃ or>25 ℃)


RTD thermistor (one year, ambient temperature 20 ℃± 5 ℃)

Thermal resistance index number temperature range Maximum allowable error (analog output) Maximum allowable error (measurement)
0.01 level 0.02 level 0.05 level 0.01 level 0.02 level 0.05 level
Pt100 (– 200~0)℃ ± 0.05℃ ± 0.07℃ ± 0.12℃ ± 0.05℃ ± 0.07℃ ± 0.12℃
(0~400)℃ ± 0.09℃ ± 0.20℃ ± 0.28℃ ± 0.09℃ ± 0.14℃ ± 0.28℃
(400~600)℃ ± 0.11℃ ± 0.20℃ ± 0.37℃ ± 0.11℃ ± 0.18℃ ± 0.37℃
(600~850)℃ ± 0.14℃ ± 0.30℃ ± 0.50℃ ± 0.14℃ ± 0.23℃ ± 0.50℃
Pt1000 (– 200~0)℃ ± 0.05℃ ± 0.10℃ ± 0.11℃ ± 0.05℃ ± 0.07℃ ± 0.12℃
(0~400)℃ ± 0.08℃ ± 0.13℃ ± 0.28℃ ± 0.09℃ ± 0.14℃ ± 0.28℃
(400~600)℃ ± 0.11℃ ± 0.17℃ ± 0.37℃ ± 0.11℃ ± 0.18℃ ± 0.37℃
(600~850)℃ ± 0.14℃ ± 0.23℃ ± 0.50℃ ± 0.14℃ ± 0.23℃ ± 0.50℃
Cu50 (– 50~150)℃ ± 0.07℃ ± 0.10℃ ± 0.17℃ ± 0.07℃ ± 0.10℃ ± 0.17℃
BA1 (– 200~0)℃ ± 0.06℃ ± 0.08℃ ± 0.13℃ ± 0.06℃ ± 0.08℃ ± 0.13℃
(0~400)℃ ± 0.10℃ ± 0.15℃ ± 0.30℃ ± 0.10℃ ± 0.15℃ ± 0.30℃
(400~650)℃ ± 0.13℃ ± 0.20℃ ± 0.41℃ ± 0.13℃ ± 0.20℃ ± 0.41℃
BA3 (– 50~100)℃ ± 0.08℃ ± 0.10℃ ± 0.18℃ ± 0.05℃ ± 0.07℃ ± 0.15℃
G (– 50~150)℃ ± 0.07℃ ± 0.09℃ ± 0.17℃ ± 0.07℃ ± 0.09℃ ± 0.17℃

Note: ① Compliant with the 90 international temperature scale, determined by the maximum allowable error between the resistance output and measurement;

② JY820 products do not have Pt1000 or BA3.


TC thermocouple (one year, ambient temperature 20 ℃± 5 ℃)

Thermocouple division number temperature range Maximum allowable error (analog output and measurement)
0.01 level 0.02 level 0.05 level
S (– 20~200)℃ ± 0.9℃ ± 0.9℃ ± 0.9℃
(200~700)℃ ± 0.5℃ ± 0.5℃ ± 0.6℃
(700~1500)℃ ± 0.5℃ ± 0.6℃ ± 0.8℃
(1500~1768)℃ ± 0.5℃ ± 0.6℃ ± 1.0℃
R (– 20~100)℃ ± 0.9℃ ± 0.9℃ ± 0.9℃
(100~600)℃ ± 0.6℃ ± 0.6℃ ± 0.6℃
(600~1600)℃ ± 0.4℃ ± 0.5℃ ± 0.8℃
(1600~1768)℃ ± 0.5℃ ± 0.6℃ ± 1.0℃
J (– 210~– 100)℃ ± 0.3℃ ± 0.3℃ ± 0.4℃
(– 100~300)℃ ± 0.2℃ ± 0.2℃ ± 0.2℃
(300~900)℃ ± 0.2℃ ± 0.2℃ ± 0.4℃
(900~1200)℃ ± 0.2℃ ± 0.3℃ ± 0.5℃
K (– 250~–150)℃ ± 1.0℃ ± 1.1℃ ± 1.3℃
(–150~1000)℃ ± 0.2℃ ± 0.3℃ ± 0.5℃
(1000~1372)℃ ± 0.3℃ ± 0.4℃ ± 0.7℃
T (– 250~–200)℃ ± 0.8℃ ± 0.8℃ ± 1.0℃
(–200~0)℃ ± 0.3℃ ± 0.4℃ ± 0.4℃
(0~400)℃ ± 0.2℃ ± 0.2℃ ± 0.2℃
N (– 200~– 100)℃ ± 0.5℃ ± 0.5℃ ± 0.6℃
(–100~600)℃ ± 0.3℃ ± 0.3℃ ± 0.3℃
(600~1300)℃ ± 0.3℃ ± 0.4℃ ± 0.6℃
E (– 250~–200)℃ ± 0.5℃ ± 0.6℃ ± 0.8℃
(–200~700)℃ ± 0.2℃ ± 0.3℃ ± 0.3℃
(700~1000)℃ ± 0.2℃ ± 0.3℃ ± 0.5℃
B (600~800)℃ ± 0.8℃ ± 0.8℃ ± 0.9℃
(800~1100)℃ ± 0.6℃ ± 0.6℃ ± 0.7℃
(1100~1820)℃ ± 0.5℃ ± 0.6℃ ± 0.8℃
WRe3-25 (0~1800)℃ ± 0.5℃ ± 0.6℃ ± 1.0℃
(1800~2200)℃ ± 0.7℃ ± 0.9℃ ± 1.6℃
(2200~2315)℃ ± 0.8℃ ± 1.2℃ ± 2.0℃
WRe5-26 (0~1000)℃ ± 0.3℃ ± 0.4℃ ± 0.6℃
(1000~1800)℃ ± 0.5℃ ± 0.7℃ ± 1.1℃
(1800~2315)℃ ± 0.8℃ ± 1.1℃ ± 1.9℃

Note: ① Compliant with the 90 international temperature scale, determined by the maximum allowable error of mV output and measurement;

  ② Excluding sensor and compensation wire errors;

  ③ Accuracy with external cold contacts, adding 0.2 ℃ for internal contacts;

  ④ The maximum allowable error of Pt100 temperature probe is ± 0.20 ℃.


Other indicators

project specifications
Warm-up time After 5 minutes of startup, the technical specifications are met
Electrical measurement connection 4mm gold-plated lantern plug
Side port connection Pressure/24V DC
Temperature measurement/switch
HART/RS232 connection
Aviation plug
Charger connection φ (5.5 × 2.5) mm DC port
External dimensions (205x110x52)mm
weight About 0.9kg
display 3.7-inch monochrome dot matrix LCD display screen
Display Contrast adjustable
Button backlight LED, closable
Battery Category Capacity Lithium battery pack 7.4V/4800mAh, 36Wh
Battery life Charge and discharge more than 300 times
Battery charging time About 4 hours
battery life 12 hours (measurement and output, turn on circuit power 12mA, screen and button backlight on);
>15 hours (measurement and output, screen and button backlight on);
16 hours (measurement or output, screen and button backlight on, continuous).
Adapter input (100–240)V AC,(50–60)Hz
Adapter output 8.6V DC/1A
operation temperature (-10~50)°C
storage temperature (-20~60)°C
Maximum relative humidity without condensation 90% at 35 ° C;
At 75% and 40 ° C;
45% at 50 ° C.


optional function

  • Secondary instrument calibration software

-National metrological verification regulations with multiple instruments, unified management of relevant information of the tested instruments;

-Automatically execute the calibration process, analyze data, and generate calibration certificates (calibration reports) and other reports;

-Can import custom report templates (Excel documents) and manage reports and templates uniformly according to customer verification requirements;

-The on-site detection data stored in the calibrator can be uniformly managed for data copying, editing, storage, printing, etc;

-The calibrator can be operated remotely through a computer, and can perform signal source output or signal acquisition work for a long time, while managing corresponding data;

-Provides signal conversion tools for 10 types of thermocouples and 8 types of thermal resistors.

  • JY7000 digital pressure module of Jinyi

-The pressure units can be in Pa, kPa, MPa, psi, bar, mbar, inHg, mmHg, inH2O、mmH2O、atm、Torr、lbf/ft2、 kgf/cm2Switching between them;

-Zero pressure value;

-Pressure percentage display;

-Pressure peak recording;

-Pressure overload alarm;

-The number of pressure display digits can be set to 4, 5, or 6;

-Pressure switch test;

-Countdown pressure leak detection.


Selection List

JY800 series JY824 JY823 JY822 JY821 JY820 JY810
output signal voltage
Millivolt voltage
electric current
resistance
10 types of thermocouples
6 types of thermal resistors 4 types
frequency
24V DC circuit power supply
Measurable Signal voltage
Millivolt voltage
electric current
resistance
10 types of thermocouples
6 types of thermal resistors 4 types
frequency
Other functions HART communication
Secondary instrument calibration software Optional Optional Optional Optional
Communication Protocol and Control Free download
JY800 series JY824 JY823 JY822 JY821 JY820 JY810
output range 10.99999 V 10.99999 V 10.99999 V
1.099999 V 1.099999 V 1.099999 V
-99.9999 mV~109.9999 mV -99.9999 mV~109.9999 mV -99.9999 mV~109.9999 mV
10 types of thermocouples ℃ 10 types of thermocouples ℃ 10 types of thermocouples ℃
30.0999 mA 30.0999 mA 30.0999 mA
4000.00 Ω 4000.00 Ω
400.000 Ω 400.000 Ω
6 types of thermal resistors ℃ 6 types of thermal resistors ℃ 4 types of thermal resistors ℃
54999.9 Hz
5499.99 Hz
549.999 Hz
24V DC circuit power supply 24V DC circuit power supply 24V DC circuit power supply
Measurement range ± 59.9999 V ± 59.9999 V ± 59.9999 V
± 5.99999 V ± 5.99999 V ± 5.99999 V
± 599.999 mV ± 599.999 mV ± 599.999 mV
± 119.999 mV ± 119.999 mV ± 119.999 mV
10 types of thermocouples ℃ 10 types of thermocouples ℃ 10 types of thermocouples ℃
± 119.999 mA ± 119.999 mA ± 119.999 mA
± 23.9999 mA ± 23.9999 mA ± 23.9999 mA
5999.99 Ω 5999.99 Ω
599.999 Ω 599.999 Ω
6 types of thermal resistors ℃ 6 types of thermal resistors ℃ 4 types of thermal resistors ℃
59999.9 Hz
9999.99 Hz
999.999 Hz