E-mail
15888188000@139.com
- Phone
-
Address
No. 223 North Binjiang Road, Yuyao City, Zhejiang Province
Zhejiang Jinyi Instrument Co., Ltd
15888188000@139.com
No. 223 North Binjiang Road, Yuyao City, Zhejiang Province
Product Details
Feature Overview
Output signal: The pulse signal is generated by the internal circuit triggered by the button. Each time the "trigger" button is pressed, each output channel can generate pulse signals with adjustable delay (or time interval) and adjustable period;
The number of pulse outputs can be set arbitrarily from 1 to 10;
Pulse signals can be output with or without delay through digital settings;
Output can be selected as "single" or "continuous" mode:
When choosingWhen "single time" is used, press the "trigger" button, and each channel outputs a pulse signal with a set delay and pulse width;
When choosingWhen "continuous", each channel can output 1-10 consecutive pulse signals with set delay and pulse width.
technical indicators
| project | Specifications |
| Allowable voltage for idle contacts | ≤300V |
| Allowable current for open contacts | ≤50mA |
| Delay (time interval) resolution | 0.01ms |
| Delay range | According to the pulse width, the maximum delay is 9998ms |
| duty cycle | 1:1 |
| Delay accuracy | 0.05ms |
| battery | 4.8V/1900mAh nickel hydrogen battery pack |
| Nickel hydrogen battery usage time | More than 12 hours |
| display screen | 128x128 dot matrix LCD backlight |
| weight | 650g (including battery) |
| product casing | ABS plastic |
| Overall dimensions | (205x115x45)mm |
| Operating Temperature | (-10~50)°C |
| Storage temperature | (-20~60)°C |
| Relative humidity (maximum, no condensation) | 90% at 35 ° C; At 75% and 40 ° C; 45% at 50 ° C. |