Welcome Customer !

Membership

Help

Guangzhou Dichuan Instrument Co., Ltd
Custom manufacturer

Main Products:

foodequippro>Products

Guangzhou Dichuan Instrument Co., Ltd

  • E-mail

    gzdckj168@sina.com

  • Phone

    15302383334

  • Address

    4th Floor, East Building, Hengxing Industrial Park, No. 125 Qianfeng South Road, Shiji Town, Panyu District, Guangzhou City

Contact Now

Intelligent integrated gas turbine flowmeter

NegotiableUpdate on 03/17
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The intelligent integrated gas turbine flowmeter has a wide measurement range, with a lower limit flow rate of less than 0.5m/s, low pressure loss, strong anti impact ability of the impeller, strong anti electromagnetic interference and anti vibration ability, reliable performance, long working life, and can perform pressure compensation under stable pressure state of the measured gas. The built-in pressure and temperature sensors have high safety performance, compact structure, and beautiful appearance

Product Details

OneOverview

Intelligent integrated gas turbine flowmeterThe measurement range is wide, with a lower limit flow rate of less than 0.5m/s, low pressure loss, strong anti impact ability of the impeller, strong anti electromagnetic interference and anti vibration ability, reliable performance, long working life, and can perform pressure compensation under stable pressure state of the measured gas. The built-in pressure and temperature sensor has high safety performance, compact structure, and beautiful appearance.

Intelligent integrated gas turbine flowmeterProduct Features:
Low pressure loss and impeller with anti-corrosion function;
Adopting advanced ultra-low power single-chip microcomputer technology, the whole machine has strong functions, low power consumption, and superior performance;

Intelligent flow display with non-linear accuracy compensation function. The accuracy of the correction formula is better than ± 0.02%;

The instrument coefficient can be set online by buttons and displayed on the LCD screen, which is intuitive, clear, and highly reliable;
Using EEPROM for power down protection of accumulated flow and instrument coefficient, with a protection time greater than 10 years;
Using high-performance MCU central processing unit to complete data acquisition, processing, display output, cumulative flow and instantaneous flow;

Convenient human-machine interface implementation with screen display, data transmission in standard 485 format;

Adopting fully cemented carbide (tungsten carbide) shielded cantilever beam structure bearings, integrating rotating bearings and pressure bearings, greatly improving the bearing life, and can work in media with a small amount of sediment and dirt;

Adopting 1Cr18Ni9Ti all stainless steel structure (2Cr13 for turbine), it has good anti-corrosion performance.

Easy to repair, with a self rectifying structure, small and lightweight, simple structure, can be assembled and disassembled in a short time, and easy internal cleaning;
Has strong resistance to magnetic interference and vibration, reliable performance, and long lifespan;
Low lower flow rate, wide measurement range, clear and intuitive display on the on-site LCD screen, low power consumption, and continuous 3V lithium battery power supply

Operating for over 5 years, corrosion-resistant, suitable for acidic and alkaline solutions.

【LWQ gas vortexRotating gaugeTechnical Parameters

Nominal diameter: Pipeline type: DN4~DN200 Insertion type: DN100~DN2000
Accuracy level: Pipeline type: ± 0.5 level, ± 1.0 level Insertion type: ± 1.5 level, ± 2.5 level
Environmental temperature: -20 ℃~50 ℃
Medium temperature: Measuring liquid: -20 ℃~120 ℃ Measurement gas: -20 ℃~80 ℃
Atmospheric pressure: 86KPa~106KPa
Nominal pressure: 1.6 Mpa, 2.5 Mpa, 6.4 Mpa, 25 Mpa
Explosion proof grade: ExdIIBT4
Connection methods: threaded connection, flange clamping, flange connection, plug-in, etc
Requirements for straight pipe section: Gas: The upstream straight pipe section should be ≥ 10DN, and the downstream straight pipe section should be ≥ 5DN
Liquid: The upstream straight pipe section should be ≥ 20DN, and the downstream straight pipe section should be ≥ 5DN
Insertion type: The upstream straight pipe section should be ≥ 20DS, and the downstream straight pipe section should be ≥ 7DS (DS is the measured inner diameter of the pipeline)
Display mode:

(1) Remote transmission display: pulse output, current output (with display instrument)
(2) On site display: 8-bit LCD displays cumulative flow rate, unit (m3) 4-digit
LCD displays instantaneous flow rate, unit (m3/h), battery level, frequency, and flow rate
(3) Temperature and pressure compensation type:
A、 Display standard instantaneous flow and standard cumulative flow
B、 Display current pressure, temperature, battery voltage
Output function:

(1) Pulse output, p-p value determined by the power supply
(2) 4-20mA two-wire current output

(3) Unit volume pulse output and sensor raw pulse output

(4) Equipped with RS485communicationinterface
Power supply

(1)DC5~24V
(2) The standard 3V lithium battery installed inside the instrument panel can be used continuously for more than eight years

(3) Temperature pressure compensation type 3V lithium battery installed inside the instrument can be continuously used for more than four years
Transmission distance: The distance from the sensor to the display can reach up to 500M

instrument model

LWQ-N

LWQ-A

LWQ-B

LWQ-C

LWQ-D

signal output

pulse

4-20mA

Nothing

4-20mA

Optional 4-20mA/pulse

power supply

+24VDC±15%

+24VDC±15%

lithium battery

24VDC±15%

24VDC ± 15%+lithium battery

accuracy class

2.5~1.5 levels

Level 1.5~1.0

Level 1.5~1.0

measurement range

standard range

Standard range or extended range

Standard range or extended range

monitor

Nothing

have

have

temperature and pressure compensation

Nothing

Nothing

have

communication interface

Nothing

Nothing

RS485

real-time recording

Nothing

Nothing

have

Instrument material

Aluminum alloy or stainless steel

Aluminum alloy or stainless steel

Aluminum alloy or stainless steel

Explosion-proof rating

ExdIIBT6 or ExiaICIT4

ExdIIBT6 or ExiaICIT4

ExdIIBT6 or ExiaICIT4

Protection level

IP65

IP65

IP65

Total power consumption

<1W

<1W

<1W

Instrument communication

DN25~DN300

DN25~DN300

DN25~DN300

Installation method

Flange Installation

Flange Installation

Flange Installation

medium temperature

-20℃~80℃

-20℃~80℃

-20℃~80℃

ambient temperature

-30℃~60℃

-30℃~60℃

-30℃~60℃

instrument model

LWQ-N

LWQ-A

LWQ-B

LWQ-C

LWQ-D

signal output

pulse

4-20mA

Nothing

4-20mA

Optional 4-20mA/pulse

power supply

+24VDC±15%

+24VDC±15%

lithium battery

24VDC±15%

24VDC ± 15%+lithium battery

accuracy class

2.5~1.5 levels

Level 1.5~1.0

Level 1.5~1.0

measurement range

standard range

Standard range or extended range

Standard range or extended range

monitor

Nothing

have

have

temperature and pressure compensation

Nothing

Nothing

have

communication interface

Nothing

Nothing

RS485

real-time recording

Nothing

Nothing

have

Instrument material

Aluminum alloy or stainless steel

Aluminum alloy or stainless steel

Aluminum alloy or stainless steel

Explosion-proof rating

ExdIIBT6 or ExiaICIT4

ExdIIBT6 or ExiaICIT4

ExdIIBT6 or ExiaICIT4

Protection level

IP65

IP65

IP65

Total power consumption

<1W

<1W

<1W

Instrument communication

DN25~DN300

DN25~DN300

DN25~DN300

Installation method

Flange Installation

Flange Installation

Flange Installation

medium temperature

-20℃~80℃

-20℃~80℃

-20℃~80℃

ambient temperature

-30℃~60℃

-30℃~60℃

-30℃~60℃

measurement range

Instrument diameter

code

standard range

code

Expand range

DN25(1')

S

2.5-25 m3/h

W

4-40 m3/h

DN40 (1.5')

S

5-50 m3/h

W

6-60 m3/h

DN50 (2')

S1

6-65 m3/h

W1

5-70 m3/h

S2

10-100 m3/h

W2

8-100 m3/h

DN80 (3')

S1

13-250 m3/h

W1

10-160 m3/h

S2

20-400 m3/h

W2

DN100(4')

S1

20-400 m3/h

W1

13-250 m3/h

S2

32-650 m3/h

W2

DN150(6')

S1

32-650 m3/h

W1

80-1600 m3/h

S2

50-1000 m3/h

W2

DN200(8')

S1

80-1600 m3/h

W1

50-1000 m3/h

S2

130-2500 m3/h

W2

DN 250(10')

S1

130-2500 m3/h

W1

80-1600 m3/h

S2

200-4000 m3/h

W2

DN 300(12')

S

200-4000 m3/h

W1

130-2500 m3/h

Instrument diameter

code

standard range

code

Expand range

DN25(1')

S

2.5-25 m3/h

W

4-40 m3/h

DN40 (1.5')

S

5-50 m3/h

W

6-60 m3/h

DN50 (2')

S1

6-65 m3/h

W1

5-70 m3/h

S2

10-100 m3/h

W2

8-100 m3/h

DN80 (3')

S1

13-250 m3/h

W1

10-160 m3/h

S2

20-400 m3/h

W2

DN100(4')

S1

20-400 m3/h

W1

13-250 m3/h

S2

32-650 m3/h

W2

DN150(6')

S1

32-650 m3/h

W1

80-1600 m3/h

S2

50-1000 m3/h

W2

DN200(8')

S1

80-1600 m3/h

W1

50-1000 m3/h

S2

130-2500 m3/h

W2

DN 250(10')

S1

130-2500 m3/h

W1

80-1600 m3/h

S2

200-4000 m3/h

W2

DN 300(12')

S

200-4000 m3/h

W1

130-2500 m3/h