ZT601 typeZhongtuo floor thickness gaugeIntroduction
ZT601 floor thickness gauge is used to indirectly measure the thickness of non-metallic slabs, especially suitable for concrete slabs that cannot be directly measured. This instrument mainly utilizes the distribution characteristics of electromagnetic fields to indirectly measure the thickness of non-metallic plates. It has functions such as thickness measurement, data analysis, data storage and output, and is a portable, easy-to-use, and accurate intelligent thickness measuring instrument.
ZT601 typeZhongtuo floor thickness gaugeMain functions
1. Measure the thickness of non-metallic plates (such as concrete, rock, glass plates, etc.);
2. The storage, viewing, and deletion functions of measurement data, as well as the calculation of average values and pass rates;
3. Measurement data can be uploaded (via USB port) to external data processing software.
ZT601 typeTechnical features:
*Large measurement range greatly reduces detection time
Direction indicator, which can indicate the direction of movement of the detection probe
Can be used to run in environments such as WinXP, Win7, Win8, etc
ZT601 typeMain technical indicators
Display the position of the transmitting probe and achieve quick positioning through directional indication;
Intelligent interpretation and automatic locking, digital display of thickness values, no need for manual comparison;
3. The host and probe are designed in a separate manner, so that the host does not come into contact with the tested object during testing, avoiding damage to the host during the testing process;
4. Thickness measurement range: 40mm to 1000mm
5 Test accuracy: 40mm~600mm ± 1mm
601mm~1000mm±2mm
The testing accuracy is superior to other similar products
Data storage capacity: 4000 components or 32000 measurement data
7. Data transmission method: USB
8. PC professional data analysis software, easy to complete data processing and report generation;
9. ZT601 typeWork environment requirements
Environmental temperature: -10 ℃ to+40 ℃, avoid prolonged exposure to direct sunlight
Relative humidity:<90% RH
Electromagnetic interference: no strong alternating electromagnetic field
10. Power supply: rechargeable battery, with a power supply time of up to 50 hours
11. Appearance: 220 * 162 * 91mm
12. Weight:
ZT601 typeMain Features
1. Automatically and accurately measure the thickness of non-metallic plates;
2. Multiple measurement methods: alarm prompt sound, directional indicator arrow, black signal finger
Four methods are used for accurate measurement of thickness values: strip display, thickness value, and signal value;
3. Measurement data can be transmitted to external data processing software through a USB port for analysis and processing;
4. The software interface is simple and easy to operate.
ZT601 typeworking principle
The ZT601 floor thickness gauge consists of five main parts: transmitting probe, receiving probe, receiving signal processing system, display system, and data storage system. The transmitting probe generates an electromagnetic signal of a certain frequency on one side of the non-metallic plate, while the receiving probe receives the electromagnetic signal on the other side of the non-metallic plate and converts it into an electrical signal, which is then transmitted to the receiving signal processing system. The receiving signal processing system displays and stores the measurement results.
ZT601 typePrecautions
1. Avoid water ingress;
2. Avoid high temperatures (>50 ℃);
3. Avoid approaching very strong magnetic fields, such as large electromagnets, large transformers, etc;
4. The distance between the walkie talkie and the transmitting probe should be at least 1 meter when in use;
5. When the instrument is not used for a long time, please remove the battery to avoid battery leakage and damage to the circuit;
6. The probe battery can only be used after it is fully charged (the red light of the charger turns green);
7. Do not open the instrument casing without permission, otherwise the consequences will be borne by yourself.