Vicometo brandVM-220F multifunctional high-frequency moisture analyzerHas the following characteristics:
1. Adopting international mainstream technology and various imported chips, with stable performance and excellent quality.
2. The unique sensor design and manufacturing method have a penetrating ability beyond the general range.
3. The proprietary sensor technology has a wide working range, can be inserted for measurement, and displays quickly.
4. Multiple gear settings for measuring moisture content of different substances.
5. Backlit LCD screen display, measurement readings are not affected by light.
6. The instrument design adopts low-power technology with low power consumption.
7. The instrument design is exquisite and the structure is compact.
8. Small in size and light in weight, it can be carried on site for rapid testing, making it a good helper for on-site testing personnel to detect moisture content.
detailed parameters
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
application area
precautions
1When measuring, hold the lower half of the instrument and gently press the sensing probe of the instrument into the object being measuredThe surface is sufficient.
2Due to the strong penetrability of high-frequency waves, the presence of metal around the measured object can lead to inaccurate measurements. Therefore, during measurement, there should be no metal or other sensing objects around the instrument probe.
3The moisture meter is a contact type measuring instrument, and the measurement premise is that the long needle probe of the instrument should be in full contact with the measured object as much as possible.
4When there is no display or the zero value cannot be adjusted within ± 00.5, and the display number jumps, the battery should be replaced at this time. The battery is located below the back of the instrument. Unscrew the screws on the battery cover, remove the old battery, and replace it with a new one. If the battery cannot be zeroed after replacement, please open the battery back cover one by one and find the tail zeroing knob,Use a flat screwdriver to adjust the potentiometer in the hole, so that the zero position of the instrument is within 00.5.
5. If the instrument is not used for a long time, the battery should be removed to prevent damage to the instrument caused by battery leakage.