E-mail
yanzhijiance01@yeah. net
-
Phone
134-7259-2873
-
Address
No. 3, Lane 1998, Jinbi Road, Fengxian District, Shanghai
Shanghai Yanzhi Testing Equipment Co., Ltd
yanzhijiance01@yeah. net
134-7259-2873
No. 3, Lane 1998, Jinbi Road, Fengxian District, Shanghai
1)Continuous data can be downloaded at once;
2)Before each test, there is no need to connect to a computer, and settings can be made on the instrument;
3)Standard voltage calibration, reliable accuracy;
4)Using the current Texas Instruments acquisition chip, we will not miss any subtle temperature changes;
5)Small size, large storage capacity (460000 data points), no unexpected loss of data;
6)Real time display of channel values and display of channel average values;
7)Historical data, excel、 There are two forms of graphics, which can be copied from a USB drive;
8)You can choose to use the number of channels;
9)There are four basic screens: digital display screen, bar chart screen, (historical) curve screen, and alarm display screen;
10)Real time curve recording interval ranges from 1 second to 9999 seconds. Historical curve viewing interval can be continuously set from 1 second to 9999 seconds;
11)The host can be used inside the laminating machine, and the insulation box will not be deformed or damaged under pressure;
12)Can be tested continuously multiple times, with a maximum storage capacity of 100 sets of data; The device has a power-off memory function, and data from the data collector will not be lost in case of unexpected power outages;
13)The battery supports charging and replacement;
14)Button start, delayed start, and temperature start are three more convenient and practical startup methods;
15)Support wireless data transmission and implementation of data reading, real-time online viewing of data, software supports editable modifications.

model |
CHT-16 |
name |
Photovoltaic laminated multi-channel temperature recorder |
Thickness of insulation layer |
Thickness ≤ 20mm |
Instrument dimensions |
140*80*9.5 |
Number of testing channels |
12-16 and above channel data loggers |
sensor type |
Type K thermocouple |
test accuracy |
±0.3℃ |
data transmission |
USB transmission link data/wireless real-time transmission |
Wireless transmission signal loss rate |
≤0.2% |
Wireless transmission frequency |
0.05-200.00 seconds |
resolution |
The minimum resolution is 0.1 ℃ |
Continuous testing |
Can be tested multiple times. Maximum storage capacity of 100 sets of data |
Battery power supply |
Lithium battery/nickel hydrogen battery, with a battery life of ≥ 6H |
Instrument temperature resistance |
90.00℃ |
measurement range |
-200℃-1370℃ |
memory |
128M、 8.3 million data |
transmission method |
USB/wireless transmission |
sampling period |
0.05s,0.1s,0.2s,1s, 2s, 3s, 4s, 5s, 6s, 10s, 200s, Wait, users can choose independently. |
battery |
The instrument adopts a built-in rechargeable lithium battery. |
Startup method |
Key start, delayed start, temperature start |
calibration method |
Voltage calibration, temperature calibration |