Shanghai Standard GBT/19466 Differential Scanning Calorimeter

NegotiableUpdate on 10/02
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Brief description: The Shanghai Jiezhun GBT/19466 differential scanning calorimeter (DSC), as a classic thermal analysis method for thermal effects under controllable program temperature, has been widely used in various fields of materials and chemistry research and development, process optimization, quality control, and failure analysis. By using DSC method, we can study the phase transition of inorganic materials, the melting and crystallization process of polymer materials, the polymorphic phenomenon of drugs, and the solid/liquid phase ratio of foods such as oils and fats.

Product Details

Shanghai Standard GBT/19466 Differential Scanning Calorimeter

Differential Scanning Calorimetry (DSC), as a classic thermal analysis method for thermal effects under controllable program temperature, has been widely used in various fields such as research and development, process optimization, quality control, and failure analysis in materials and chemistry. By using DSC method, we can study the phase transition of inorganic materials, the melting and crystallization process of polymer materials, the polymorphic phenomenon of drugs, and the solid/liquid phase ratio of foods such as oils and fats.

Shanghai Standard GBT/19466 Differential Scanning CalorimeterMain Features

  • Easy to operate, no testing experience required, only a small amount of training needed
  • The software is suitable for computer screens of various resolutions
  • Dual temperature probes ensure high precision and repeatability
  • The experimental process does not require personnel supervision
  • Digital gas mass flowmeter automatically switches between two gas channelsbodytraffic
  • Software can be upgraded online for free
  • Seven inch large screen LCD display, with clear graphs and curves at a glance
  • Built in high sensitivity differential thermal sensor imported from abroad, with higher accuracy, capable of measuring weak signals(DSC-500C)

Shanghai Standard GBT/19466 Differential Scanning CalorimeterTechnical Specifications

DSC range

0~±200mW

temperature range

room temperature~500℃

heating rate

0.1~50℃/min

Temperature resolution

0.01℃

temperature accuracy

±0.1℃

Temperature repeatability

±0.1℃

DSC accuracy

±2%

DSC resolution

0.001mW

DSC resolution

0.001mW

temperature control

Full process automatic control

Curve scanning

Heating up scan

atmosphere control

Gas mass flowmeter

display mode

24 bit color, 7-inch touch screen

working power supply

AC220V 50Hz/60Hz

Size (w * d * h)

46*35*27cm

Net weight

14.5KG

Packaging size (w * d * h)

58*45*40

Gross weight

18KG

Computer configuration requirements

hardware configuration

  • Saiyang dual core
  • 2GB system memory
  • Resolution 1366 * 768 pixels or higher
  • Hard drive 500GB

software configuration

  • Win2000 or higher system
  • Adobe PDF Reader

Shanghai Standard GBT/19466 Differential Scanning CalorimeterApplication Examples

Measure physical and chemical changes related to heat, such as glass transition temperature and melting point、Melting temperature, crystallization and crystallization heat, heat of phase transition reaction, thermal stability of the product, solidification/crosslinking, oxidation induction period, reaction kinetics, specific heat, etc. Note: The thermal stability test during the oxidation induction period is applicable to the national standard GB/T 17 3 9 1-1 9 9 8.

Instrument principle

Differential scanning calorimetry is a technique that measures the power difference between a substance and a reference substance as a function of temperature under programmed temperature control. The DSC-500 series differential scanning calorimeter mainly consists of a heating furnace, a main unit, a microvolt amplifier, an A/D converter, a data acquisition system, a gas flow control system, a computer, a printer, and other components, supplemented by the switching of two atmospheres. The measurement results are processed by a computer data processing system.

Experimental diagram

Glass transition temperature automatic calculation result interface

Enthalpy variable, epitaxial starting point, melting point calculation result interface

Enthalpy ratio calculation result interface

Calculation result interface for oxidation induction period

DSC-500 series accessories list

serial number

name

quantity

1

DSC-500 type heating furnace and main unit box

1

2

DSC-500 Differential Scanning Calorimeter Working Program CD

1

3

power cable

1

4

signal cable

1

5

Glass tube fuse (3A)

4

6

tweezers

1

7

Sample key

1

8

Certificate of Conformity

1

9

Pressure reducing valve connector

2

10

Ventilation connector

4

11

Aluminum crucible (Φ 6.7 × 3mm)

400

12

Reference material(-Al2O3)

1g

13

Standard samples (In, Sn, Zn)

0.5g each

14

DSC-500 Differential Scanning Calorimeter Manual

1

15

Ventilation plastic pipe (blue)

3 meters

16

Ventilation plastic pipe (orange)

3 meters