Shanghai Standard GBT/19466 Differential Scanning Calorimeter
Differential Scanning Calorimetry (DSC), as a classic thermal analysis method for thermal effects under controllable program temperature, has been widely used in various fields such as research and development, process optimization, quality control, and failure analysis in materials and chemistry. By using DSC method, we can study the phase transition of inorganic materials, the melting and crystallization process of polymer materials, the polymorphic phenomenon of drugs, and the solid/liquid phase ratio of foods such as oils and fats.
Shanghai Standard GBT/19466 Differential Scanning CalorimeterMain Features
Shanghai Standard GBT/19466 Differential Scanning CalorimeterTechnical Specifications
DSC range |
0~±200mW |
temperature range |
room temperature~500℃ |
heating rate |
0.1~50℃/min |
Temperature resolution |
0.01℃ |
|
temperature accuracy |
±0.1℃ |
Temperature repeatability |
±0.1℃ |
DSC accuracy |
±2% |
DSC resolution |
0.001mW |
DSC resolution |
0.001mW |
temperature control |
Full process automatic control |
Curve scanning |
Heating up scan |
atmosphere control |
Gas mass flowmeter |
display mode |
24 bit color, 7-inch touch screen |
working power supply |
AC220V 50Hz/60Hz |
Size (w * d * h) |
46*35*27cm |
Net weight |
14.5KG |
Packaging size (w * d * h) |
58*45*40
|
Gross weight |
18KG |
|
Computer configuration requirements |
hardware configuration
|
software configuration
|
Shanghai Standard GBT/19466 Differential Scanning CalorimeterApplication Examples
Measure physical and chemical changes related to heat, such as glass transition temperature and melting point、Melting temperature, crystallization and crystallization heat, heat of phase transition reaction, thermal stability of the product, solidification/crosslinking, oxidation induction period, reaction kinetics, specific heat, etc. Note: The thermal stability test during the oxidation induction period is applicable to the national standard GB/T 17 3 9 1-1 9 9 8.
Instrument principle
Differential scanning calorimetry is a technique that measures the power difference between a substance and a reference substance as a function of temperature under programmed temperature control. The DSC-500 series differential scanning calorimeter mainly consists of a heating furnace, a main unit, a microvolt amplifier, an A/D converter, a data acquisition system, a gas flow control system, a computer, a printer, and other components, supplemented by the switching of two atmospheres. The measurement results are processed by a computer data processing system.
Experimental diagram

Glass transition temperature automatic calculation result interface
Enthalpy variable, epitaxial starting point, melting point calculation result interface
Enthalpy ratio calculation result interface
Calculation result interface for oxidation induction period
DSC-500 series accessories list
serial number |
name |
quantity |
1 |
DSC-500 type heating furnace and main unit box |
1 |
2 |
DSC-500 Differential Scanning Calorimeter Working Program CD |
1 |
3 |
power cable |
1 |
4 |
signal cable |
1 |
5 |
Glass tube fuse (3A) |
4 |
6 |
tweezers |
1 |
7 |
Sample key |
1 |
8 |
Certificate of Conformity |
1 |
9 |
Pressure reducing valve connector |
2 |
10 |
Ventilation connector |
4 |
11 |
Aluminum crucible (Φ 6.7 × 3mm) |
400 |
12 |
Reference material(-Al2O3) |
1g |
13 |
Standard samples (In, Sn, Zn) |
0.5g each |
14 |
DSC-500 Differential Scanning Calorimeter Manual |
1 |
15 |
Ventilation plastic pipe (blue) |
3 meters |
16 |
Ventilation plastic pipe (orange) |
3 meters |
|
|
|