E-mail
Jiaqian.Liu@PERKINELMER.COM
- Phone
-
Address
1670 Zhangheng Road, Zhangjiang High tech Park, Pudong New Area, Shanghai
Shanghai Spectral Instrument Co., Ltd
Jiaqian.Liu@PERKINELMER.COM
1670 Zhangheng Road, Zhangjiang High tech Park, Pudong New Area, Shanghai
| brand | SPECTRUM/Shanghai Spectroscopy | Background technology deduction | Deuterium lamp+self absorbing buckle background |
|---|---|---|---|
| Detector class | Photomultiplier | optical system | Dual beam |
| Monochrome component | other | price range | Negotiable |
| Instrument type | Graphite furnace |
SP-3802AAAtomic absorption spectrophotometeris a
Single beam, total reflection achromatic optical system ensures the uniformity and optical position of various elements at different wavelengths between the sample channel and the reference channel, keeping the beam imaging and signal-to-noise ratio at a stable level. After changing the lamp, there is no need to adjust the focus point position, greatly improving the accuracy, reliability, and work efficiency of the test results.
The super strong anti atomizer light radiation ability can effectively eliminate the strong light radiation of graphite tubes at high temperatures.
Intelligent stray light measurement and correction technology Effectively improved the optical accuracy and linear range of the atomic absorption spectrometer, and enhanced its background correction capability.
Optical noise reduction technology, combined with optical component ultraviolet enhancement technology, effectively improves the optical performance and linear range of the instrument.
Hollow cathode lamps are used for self-priming background correction,
Vertical heating graphite furnace technology
Vertical 8-light rack system, automatic light replacement, two-dimensional automatic fine adjustment of the aiming light rack.
Adopting deuterium lamp and self absorbing buckle background method
waveLong range: 180nm-900nm
Monochromator: C-T type monochromator with aberration correction
1800 lines/mm, scintillation wavelength 250nm
Spectral bandwidth: six automatic switching modes: 0.1nm, 0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.0nm
Wavelength accuracy: ± 0.1nm
Graphite Furnace Analysis System:
Feature quantity: Cd ≤ 0.3pg; Detection limit: Cd ≤ 0.2pg; Repeatability (RSD): Cd ≤ 2.5%.
External protective gas flow rate of graphite tube: 1L/min;
Protective gas flow rate inside graphite tube: can be set to stop or start (0-50ml/min micro flow rate or 300-400ml/min fixed flow rate);
The position of the ink furnace atomizer is free from adjustment in terms of horizontal, vertical, and rotational positions;
Safety control: cooling water flow rate, protective gas pressure, furnace temperature, graphite tube;Install automatic alarm and security protection;