The SP-3590AA atomic absorption equipment launched by Shanghai Spectra adopts an expert database information system to provide you with fast and accurate detection information and methods, greatly reducing the difficulty of analysts' work, avoiding human operation errors, and ensuring analysis accuracy. The Win-AAS workstation software based on the Windows operating platform has a user-friendly interface, easy operation, and fully conforms to PC operating habits, without the need for professional training.

Product Details

brand SPECTRUM/Shanghai Spectroscopy Background technology deduction Deuterium lamp+self absorbing buckle background
Detector class Photomultiplier optical system Single beam
Monochrome component other price range Negotiable
Instrument type Flame graphite furnace

Shanghai Spectrum has launchedSP-3590AAAtomic absorption equipmentBy adopting an expert database information system, we provide you with fast and accurate detection information and methods, greatly reducing the difficulty of analysts' work, avoiding human operational errors, and ensuring analysis accuracy. The Win-AAS workstation software based on the Windows operating platform has a user-friendly interface, easy operation, and fully conforms to PC operating habits, without the need for professional training.

  SP-3590Atomic absorption equipmentfunction:

Pre optimized working conditions.

When using deuterium lamp to fasten the background, the beam balance device is automatically adjusted.

Automatic wavelength scanning and peak searching.

Six automatic switching modes can be selected: 0.1, 0.2,. 04, 0.7, 1.4, and 2.0nm.

Automatic adjustment of negative high voltage, lamp current, automatic balance of two beams, automatic ignition, and automatic shutdown protection.

Automatic 8 lights.

Automatic security measures:

Flame assisted gas pressure abnormal monitor; Using air acetylene flame analysis, the air pressure monitor can detect changes in air pressure at any time. When abnormalities occur, the acetylene gas will be automatically cut off to safely shut down.

Graphite furnace safety measures: graphite furnace cooling water flow rate, protective gas pressure, furnace body temperature, and automatic protection and alarm for graphite tube installation.

  Technical Specifications:

Performance Specifications

Optical system: C-T type monochromator device for eliminating aberration

Wavelength range: 180.0-900nm automatic adjustment

Wavelength accuracy: 0.20nm (automatically calibrated by the system)

Wavelength repeatability: 0.10nm

Resolution: better than 0.3nm

Baseline drift: 0.005A/30min

Flame analysis

Detection limit (Cu): 0.006ug/ml

Characteristic concentration (Cu): 0.03ug/ml/1%

Burner: Metal titanium burner (100mm)

Precision: RSD; 1%

Spray: high-efficiency glass atomizer

雾化室:耐腐蚀材料雾化室

Security measures: equipped with multiple automatic protection functions

Graphite furnace analysis

Feature quantity (Cd): 0.5times; 10-12g

Detection limit (Cd): 1.0 times; 10-12g

Precision: RSD 4%

Background correction: Deuterium lamp background correction, capable of correcting 1A background

Background correction capability:; 50 correction capability

data processing

Concentration calculation methods: standard curve method (6 linear or nonlinear curves), standard addition method, interpolation method

Repeated measurement times: 1-30 times, calculate the average, provide the standard deviation and phase

Regarding the standard deviation