RVLM-A Microbial Rapid Detection System
The RVLM-A microbial rapid detection system is a high-performance portable microbial detection instrument produced by the German Royal Biotechnology Company. It has many advantages such as convenience, simple operation, rapid inspection, high sensitivity, high specificity, low consumption cost, and qualitative and semi quantitative measurement. In laboratory experiments in Europe, 80% -90% of microbial detection experiments use the RVLM-A microbial detection system, which has ultra-high sensitivity and can meet EU and domestic detection standards. It is currently the most advanced intelligent and high-quality microbial detection instrument in the industry.
Product Features:
1. Wide application range: widely used in many fields such as food, medicine, water quality, air microbial detection, etc., it can detect various samples such as solid, liquid, gas, paste, slurry, etc
2. Easy to use: A portable system can complete sampling, experimentation, post-processing, and other tasks without the need for multiple detection instruments
3. Easy to operate: Only 1ml or 1g of sample is needed for detection, and no pre-treatment is required. The operation can be completed in just 3 steps
4. High sensitivity: capable of detecting target microorganisms on the order of 1 CFU, meeting domestic and international microbiological detection standards
5. High specificity: With a specificity of up to 99.999%, it eliminates experimental interference caused by non target microorganisms
6. High accuracy: capable of 100% quantitative analysis
7. Testing quantity: 8 slots can provide 8 different experiments and 13 different standard cultivation environments simultaneously
8. Quick detection: * * * The test results can be obtained in just 10 minutes and can be used for on-site testing
9. High intelligence: capable of automatically controlling incubation temperature and incubation time, and generating experimental reports automatically
10. Fully automated: independently and continuously detect and record the number of microorganisms (CFU) in the bottle
11. No personnel or laboratory requirements, reagents can be stored at room temperature
12. Easy post-processing after experiment: Aseptic treatment after use, press the top of the shaking bottle to safely dispose of it
13. Combining the advantages of traditional testing methods: culture dish method, enzyme method (β - glucosidase analysis), immune method (antigen search), gene method (gene search)
test object
Total number of live bacteria, Escherichia coli, Escherichia coli, Enterobacteriaceae, Staphylococcus aureus, Pseudomonas aeruginosa, Salmonella, Listeria monocytogenes, Enterococcus, Clostridium perfringens
Sulfite reducing Clostridium, mold (Aspergillus, Aspergillus), yeast, Legionella, etc
Scope of application
Food (HACCP)
Kitchen, tools, surfaces (HACCP)
water quality
(CDC) Disease Control, Import and Export Inspection and Quarantine
Medicines and cosmetics
It is closely related to our lives, for example:
Coffee shops and restaurants; Water; Analytical laboratory and HACCP diagnosis; Agricultural products and related processing companies; Pharmaceutical factories, pharmacies, cosmetics factories; Environmental monitoring agencies; Water distribution company; Consumer protection groups and business management agencies; Indoor air conditioning regulation company source testing, water treatment plant.
Instructions for use
Three simple steps to obtain 100% quantitative detection results:
*Step: Put in the sample
-Open the bottle cap and add 1ml of sterile water
-Add 0.1~1.0ml (0.1~1.0g) of liquid (solid/surface) sample
-Tighten the bottle cap tightly
Step 2: Shake the bottle until the solvent is fully dissolved or mixed
-If an oscillator is used, it takes about 20 seconds; Or shake vigorously with your hands, which takes about 2-3 minutes
Step 3: Read the results at the appropriate time
-Using RVLM Microbial Detector:
-After fully dissolving and mixing, immediately put it into the testing machine
-Obtain 100% quantitative analysis results
If there is no RVLM microbiological detector:
-After fully dissolving and mixing, incubate in a thermostat
-Visual interpretation of qualitative or semi quantitative analysis results
Taking Escherichia coli as an example:
If the colony count is greater than 108 CFU/ml, the color will turn yellow within 2 hours
If the colony count is less than 102 CFU/ml, the color will not turn yellow within 14 hours
If the colony does not exist: After 18 hours, the color still maintains the initial color or other intermediate color (does not turn yellow)
Safely dispose of after use, press the top of the microbial monitoring bottle cap and discard directly, non hazardous and non chemically contaminated
Product Parameters:
|
high sensitivity
|
Detected target microorganisms with an order of magnitude of 1 CFU |
|
high specificity
|
99.999% |
|
accuracy
|
100% quantitative analysis |
|
test sample
|
The detection sample only requires 1ml or 1g, and no pre-treatment is required |
|
detection quantity
|
8 slots can provide 8 different experiments and 13 different standard cultivation environments simultaneously |
|
intelligentization
|
Automatic control of incubation temperature and incubation time, and automatic generation of experimental reports |
|
meet the standard
|
Meet domestic and international microbiological testing standards |
|
High speed performance
|
***The test results can be obtained in almost 10 minutes and can be used for on-site testing |
|
Safe disposal
|
Aseptic treatment after use, press the top of the shaking bottle to safely dispose of it |
|
Easy to operate
|
No personnel or laboratory requirements, reagents can be stored at room temperature |
|
detection method
|
Combining the advantages of traditional testing methods (culture dish method, enzyme method, immune method, gene method) |
|
Reading range
|
1~9.999×1099CFU |
|
power supply method
|
Dual mode power supply of AC and DC |
|
test object
|
Total number of live bacteria, Escherichia coli, Pseudomonas aeruginosa, Enterococcus, Staphylococcus aureus, Enterobacteriaceae Listeria, Escherichia coli, Salmonella, yeast, Clostridium perfringens, Legionella Sulfite reducing Clostridium, fungi (Aspergillus, Aspergillus), etc |