PDM5000 Building Energy Management System

NegotiableUpdate on 11/05
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Brief description: The PDM5000 building energy management system is suitable for monitoring and management of medium and low voltage substations, factories, buildings, residential distribution, and distribution systems. The application of this system has effectively improved the informatization and intelligent management level of the distribution network. The PDM5000 interface is simple, with complete parameters and easy control. At the same time, its 2ms refresh rate ensures the authenticity and real-time performance of data. Whether users are searching for parameters on-site or accessing them remotely through the Internet, the system can accurately reflect real-time energy consumption and power environment.

Product Details

PDM5000Welcome to contact Tang GongWe mainly specialize in fire equipment power monitoring, motor protection controllers, multifunctional meters, rail mounted energy meters, electrical fire monitoring, intelligent lighting control, and intelligent control devices for switchgear
PDM5000 Building Energy Management SystemPDM5000
PDM5000 Building Energy Management SystemPDM5000

Nanjing Swo Electric Co., Ltd
PDM5000 Product Introduction
PDM5000 is suitable for monitoring and management of medium and low voltage substations, factories, buildings, residential distribution, and distribution systems. The application of this system has effectively improved the informatization and intelligent management level of the distribution network. The PDM5000 interface is simple, with complete parameters and easy control. At the same time, its 2ms refresh rate ensures the authenticity and real-time performance of data. Whether users are searching for parameters on-site or accessing them remotely through the Internet, the system can accurately reflect real-time energy consumption and power environment. The PDM5000 building energy consumption analysis and management system adopts two collection methods for energy consumption data: manual collection and automatic collection, in accordance with the relevant "technical guidelines" and "technical specifications" requirements for building energy consumption analysis and management. The manually collected data includes building information, energy consumption that cannot be automatically collected, etc; The automatically collected data includes building sub item energy consumption data and classified energy consumption data, which are collected in real time by automatic measuring devices and transmitted to the data center in real time through automatic transmission. The PDM5000 power monitoring system can communicate and collect data from various power monitoring equipment, ensuring the safe operation of the distribution network and conducting classified and itemized statistical analysis of various energy consumption points;

PDM5000 functional features
*High quality industrial grade components, high-density integrated circuit structure, excellent electrical isolation and electromagnetic shielding performance, no adjustable components in the whole machine, fanless design, greatly improving the anti-interference performance and reliability guarantee of the device;
A dynamic user interface that combines real-time display and control functions, allowing users to switch between normal and emergency situations
*Platform support: Compatible with multiple subsystems, provides comprehensive strategy management, offers open APIs, adopts security measures to ensure information isolation and data security, and has permission settings for multi-level, multi-dimensional, and multi system data to ensure that personnel outside the organization cannot access it beyond their boundaries;
Improve the management of the power distribution system. Timely grasp the daily or seasonal load characteristics through historical recorded power parameters; Optimize energy allocation and balance loads within the power supply and distribution system; Reduce potential power outages;
Easy to use configuration tool, reducing system development and configuration work


PDM5000 Technical Specifications
Report Statistics
The system generates various types of data reports, including usage data reports, event record reports, etc. Users can customize reports according to their own needs, and the system will generate reports on a regular basis. Reports are divided into three categories: daily reports, monthly reports, and annual reports.
Archives Management
Backup and recovery of archives
Backup the archive information to a txt file, which can also be restored to the database.
data query
Query the relevant data of on-site energy equipment, such as the positive active power of the electricity meter, the current cubic meter of water consumption of the water meter, the current cubic meter of gas consumption of the gas meter, and the current heat of the heat meter.
The queried data supports table and curve display, and can also be exported to Excel for users to perform statistical analysis as needed.
Event inquiry
The items are divided into four categories: on-site concentrator items, on-site meter items, user operation items, and system definition items. Through these items, the operation status of some devices can be monitored, the accuracy of data, and who has performed what operations on the system.
Personnel Management
Classification editing of archives
According to the classification of files, perform classification editing, and export file information to Excel during classification editing. After batch processing files in Excel, they can be directly imported into the system (note that the Excel version is 2003).
data security
The security of the system is crucial for the system, so in system design, the security of the system and data should be fully considered, and disaster prevention and recovery design should be carried out, such as cold and hot backup of the database, data protection in case of equipment power failure, etc. System functions
There are three types of system operators: super administrators, department administrators, and regular operators.
Super administrators can add and modify information and operational permissions for any operator, with full authority.
Department administrators can only add and modify the information and operational permissions of personnel within their department.
Ordinary operators can only modify their own information and operational permissions.
Topology editing of archives
Edit files on nodes in the network topology diagram. remote control
Remote parameter configuration of remote control devices, remote upgrade of device programs, remote device action control (such as water and gas meter switch valve control and remote power cut-off control of electricity meters), etc.
Energy Cockpit: Provides an overview of the overall information of the data center, displaying basic project information, electricity trends, annual/monthly/weekly energy consumption overview, departmental energy consumption/KPI ranking, alarm overview, and other information with illustrations and text;

*****Industry News*****
Especially for the latter, according to the 2015 Photovoltaic Power Generation Construction Implementation Plan issued by the * Energy Bureau, the total scale of newly added photovoltaic power stations in China will be 17.8GW in 2015, The Addis Ababa Djibouti Railway has opened up the main transportation artery between Ethiopia and Djibouti, and the supporting ultra high voltage transmission line project has formed two air power channels. Unlike fuel powered buses that have been used for so many years, which are relatively mature in terms of products and daily maintenance, they are basically provided by vehicle manufacturers for services and consultations. Therefore, in the future, based on power electronics technology, nanomaterials, low-power technology, etc., the distribution network can also achieve power quality control and reduce system losses. This series of orders has brought the beginning to the alliance between Shanghai Electric and Ansaldo. Although the widening peak valley electricity price difference is good for the energy storage industry, it has damaged the interests of power grid enterprises. Reporter: The new concept established in October 2001. Electrical has become a rising star among intelligent power equipment suppliers,

*****Project Case*****
☆ Hunan Xiangtan Power Plant
☆ Shanghai Pudong Garbage Power Plant
☆ Tianjin Youth Activity Center
☆ Xishui, Dongying, Shandong
Shandong Xinfa Aluminum Power Plant
Shanghai Yangshupu Power Plant
Hualian Youcheng Large Shopping Mall
☆ Guangdong Tobacco Industry Co., Ltd. Guangzhou Production Base Laboratory Project
☆ Shandong Linyi Power Plant
☆ Lushi Mountain Villa


PDM5000 Building Energy Management
PDM5000 Building Energy Management
PDM5000Welcome to contact Tang GongWe mainly specialize in fire equipment power monitoring, motor protection controllers, multifunctional meters, rail mounted energy meters, electrical fire monitoring, intelligent lighting control, and intelligent control devices for switchgear