Welcome Customer !

Membership

Help

Nanjing Swo Electric Co., Ltd
Custom manufacturer

Main Products:

foodequippro>Products

Nanjing Swo Electric Co., Ltd

  • E-mail

    3103075172@qq.com

  • Phone

    18921998062

  • Address

    Maigaoqiao Entrepreneurship Park Technology Research and Development Base, Qixia District, Nanjing City

Contact Now

Multi functional electric meter YD8300

NegotiableUpdate on 11/05
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Brief description: The YD8300 multifunctional electric meter adopts a large-scale integrated circuit modular design, designed and manufactured for the power monitoring needs of power systems, industrial automation, public facilities, intelligent switchgear, building automation, energy management systems, etc YD8300 uses a long-life LCD display to display instrument measurement parameters and operational information of the power grid system YD8300 multifunctional power meter is widely used in various distribution, metering, and power collection and transmission systems YD8300 three-phase multifunctional power meter is an intelligent device used for medium and low voltage systems (6-35kV and 0.4kV)

Product Details

YD8300Multi functional electric meter YD8300
YD8300Multi functional electric meter YD8300

*YD8300 Product Introduction
YD8300 adopts a large-scale integrated circuit modular design, designed and manufactured for the power monitoring needs of power systems, industrial automation, public facilities, intelligent switchgear, building automation, energy management systems, etc YD8300 uses a long-life LCD display to display instrument measurement parameters and operational information of the power grid system YD8300 multifunctional power meter is widely used in various distribution, metering, and power collection and transmission systems YD8300 three-phase multifunctional power meter is an intelligent device used for medium and low voltage systems (6-35kV and 0.4kV) YD8300 can achieve analog (DC 4-20mA) transmission output function for current or voltage (specified when ordering), with the maximum load of analog output being 300 Ω YD8300 has the function of simultaneously measuring current, voltage, frequency, active power, reactive power, electrical energy, power factor, etc. in the power grid YD8300 has multiple expansion function modules to choose from: it can be expanded to 2 * speed RS485 communication interfaces and adopts MODBUS-RTU protocol YD8300 standard configuration includes 1 * speed RS485 communication interface, using MODBUS-RTU protocol to achieve communication networking

2、 YD8300 functional features
● Accumulative range of electric energy: 0.00Wh~99999Wh or 0.00kWh~99999kWh. If it exceeds the maximum range, it will automatically reset to zero!
● Insulation strength: IEC 60255-5 2kVrms-1min
● Allowable over range: instantaneous: 2 times/2 seconds; Duration: 1 2 times
Current measurement display range: 0.000~9999A, decimal point automatically switches according to the size of the measured value
Accuracy: ≤± 0.5%
● Signal input: Current channel: Directly connect below 0-10A, add standard splitter DC 75mV input signal if exceeding 10A
● Electrical characteristics: collector * open circuit voltage VCC current
Damp heat IEC 60068-1-3 93% RH 40 ℃
Output: RS485 communication interface (Modbus RTU) protocol
● Storage of IEC 60068-1 and 2-25 ℃~+70 ℃

3、 Installation and usage precautions
When stored for a long time without use, please power on for at least 4 hours every three months.
If the instrument does not display, the auxiliary power supply should be checked first to ensure that the voltage is within the range.
The input wire should not be too long. If the input end of the tested signal is too long, please try using twisted pair shielded wire.
If the signal is accompanied by * frequency interference, a low-frequency filter should be tested online.
Remove the instrument and install the card;
Before use, the instrument needs to be powered on for 15 minutes.
To calibrate instruments, the calibration instrument should be better than level 0.1 to ensure calibration accuracy.
Unless the PT has sufficient power, the PT signal cannot be used as an auxiliary power source to ensure the normal operation of the instrument.
Insert the instrument into the installation hole of the distribution cabinet;
If the display is abnormal, check if the input signal is normal and if the signal terminals are tightened.

4、 Swo Project Case
Beijing Luodun Shahe Education Park Shanxi Taiyuan Airport Panluo Gong dispatched an office building Baroque Business Hotel in Nanchong City Beijing Jinding Street renovation Rizhao Experimental Primary School Residential building of Beijing Railway Industry Corporation Shaanxi Shangzhou District State Taxation Bureau Saint Petersburg, Russia Warm Home Residential Community in Qiuyuan County, Inner Mongolia Pudong Financial Building Beijing Indonesia Pavilion Beijing Roman Garden Beijing Sea Residence Shandong Binhua Group