Welcome Customer !

Membership

Help

Nanjing Swo Electric Co., Ltd
Custom manufacturer

Main Products:

foodequippro>Products

Nanjing Swo Electric Co., Ltd

  • E-mail

    3103075172@qq.com

  • Phone

    18921998062

  • Address

    Maigaoqiao Entrepreneurship Park Technology Research and Development Base, Qixia District, Nanjing City

Contact Now

NY5000-E Energy Efficiency Management System

NegotiableUpdate on 11/05
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Brief description: The NY5000-E energy efficiency management system mainly focuses on power quality monitoring, while also considering analysis, measurement, and assessment functions, such as steady-state, transient, power supply balance, line loss analysis, etc. The NY5000-E energy management system focuses on analyzing the rationality of electricity consumption, that is, by sorting out the user's distribution network and setting up energy meters at each node of the network, a reasonable electricity metering system is built for the distribution network. The system reflects the integrity of the measurement system through rich data reports.

Product Details

NY5000-EWelcome to contact Tang GongWe mainly specialize in fire equipment power monitoring, motor protection controllers, multifunctional meters, rail mounted energy meters, electrical fire monitoring, intelligent lighting control, and intelligent control devices for switchgear
NY5000-E Energy Efficiency Management SystemNY5000-E
NY5000-E Energy Efficiency Management SystemNY5000-E

Nanjing Swo Electric Co., Ltd

Nanjing Swo Electric Co., Ltd. specializes in the production of multifunctional power meters, rail type energy meters, fire equipment power monitors, fire door monitors, motor protectors, intelligent control devices for switchgear, and other low-voltage distribution intelligent instruments. Our products, services, and competitive prices welcome customers to inquire and purchase!


NY5000-E Product Introduction
The NY5000-E system mainly focuses on power quality monitoring, while also considering analysis, measurement, and assessment functions, such as steady-state, transient, power supply balance, line loss analysis, etc. The NY5000-E energy management system focuses on analyzing the rationality of electricity consumption, that is, by sorting out the user's distribution network and setting up energy meters at each node of the network, a reasonable electricity metering system is built for the distribution network. The system reflects the integrity of the measurement system through rich data reports. NY5000-E network prepaid system: management mode: buy electricity first, use electricity later, receive electricity bills in advance, and improve cash flow; Automatic tripping of overdue fees, power supply shutdown, no collection of electricity bills, reducing system management workload; Timely detection of electricity theft behavior to avoid loss of power supply revenue; Load control, automatic tripping when overloaded, greatly improves the safety and lifespan of power distribution equipment operation. The NY5000-E power monitoring system can communicate and collect data from various power monitoring equipment, ensuring the safe operation of the distribution network and conducting classified and itemized statistical analysis of various energy consumption points;



NY5000-E functional features
The motor has protection functions such as short circuit, overload, locked rotor, phase failure/imbalance, overvoltage, undervoltage, underload, leakage/grounding, tE time, phase sequence protection, etc
Visual display of power and hard drive conditions can better improve the effectiveness of the system
Size: (W × H × D) 482 × 177 × 480
Refined management: Real time statistics of energy efficiency assessment data and carbon emissions data from the Civil Aviation Administration of China provide data support for refined management, improve airport service quality and passenger satisfaction. The intelligent distribution monitoring system adopts a hierarchical layout structure, consisting of three layers: the main control layer, the intermediate layer, and the on-site layer.
Main control layer: The main control layer includes backend monitoring equipment and workstations, serving as the control center of the system and capable of collecting, processing, and monitoring data for the entire system.
Middle layer: The middle layer is the link that constitutes the system network, which completes the exchange of information between the main control layer and the field layer, enables the access of automation devices, and realizes the conversion and access of communication physical media and protocols.
On site layer: The on-site layer equipment completes functions such as measurement, protection, control, and operation monitoring, and is composed of intelligent devices such as low-voltage intelligent protection devices and comprehensive power measurement and control instruments. Intelligent devices have communication functions, which transmit device measurement, protection functions, alarm and other information to the main control layer through the intermediate layer for remote monitoring.


NY5000-E Technical Specifications
The NY5000-E system follows the guidelines for collecting sub item energy consumption data in the residential construction sector, dividing building electricity consumption into lighting sockets, air conditioning, power, and special electricity for metering device selection and setting. It is also divided and statistically analyzed according to energy consumption areas or functional areas, and presents the energy consumption of the area in the form of reports and comparative bar charts.
The NY5000-E system can accurately locate equipment or areas with high energy consumption, making it easier for management to develop energy-saving performance evaluation systems and promote the truly effective implementation of energy conservation and consumption reduction. Establish operation record files for key energy consuming equipment, track and record the energy efficiency analysis and evaluation results during the operation of the equipment for a long time, and provide a basis for the operation and maintenance of the equipment in combination with maintenance records.
The NY5000-E system can reflect the overall energy consumption comparison of buildings on the same day and yesterday, the same period of the current month and the previous month, and the same period of the previous year, and display the energy consumption trends of buildings in the past 48 hours, 1 month, 12 months, and 3 years, as well as the comparative analysis of energy consumption in the current year and the sub item energy consumption pie chart of the current month. Facilitating the comparison and analysis of energy consumption trends by property owners, determining energy consumption trends, adjusting equipment operation plans in a timely manner, and saving energy consumption.
The NY5000-E system can calculate the energy consumption of various categories of buildings, including electricity, water, gas, centralized heating, centralized cooling, and other energy consumption, based on the year of use, and automatically convert them into corresponding standard coal consumption, thus reflecting the energy consumption and comprehensive energy consumption of various categories of buildings in the current year. The system displays the consumption trends of various types of energy consumption in curve graphics, making it easy for owners to have a real-time and intuitive understanding of energy consumption.
The NY5000-E system is capable of uploading building energy consumption data information to the higher-level data center platform in accordance with the requirements of the "Technical Guidelines for Sub item Energy Consumption Data Transmission of Energy Consumption Monitoring Systems for Government Office Buildings and Public Buildings" and local energy-saving technical regulations and specifications of the province or city where the building is located, in accordance with established data formats and upload methods. The NY5000-E system selects and sets energy consumption measurement points based on the distribution of energy consumption in Zhuwu, so that the energy monitoring system can cover the entire building. System users can access the energy consumption statistics report of each energy consumption node in the building through the relevant interface, reducing the "running, emitting, dripping, leaking" and measurement errors of energy consumption.
Real time data collection and monitoring: Real time monitoring of parameters such as power, current, voltage, etc. for different circuits and devices. The NY5000-E system provides a hierarchical permission management function and an open information maintenance interface for authorized users. Users can add, delete, modify, and query information on measurement points within the monitoring range of buildings and systems. Building information includes building type, construction year, building area, number of building tasks, etc. The system also provides manual input function for measurement information that cannot be automatically collected, making it easier for users to comprehensively grasp the overall energy consumption of the building.


*****Industry News*****
Entering a new stage of development, Hitachi Construction Machinery will give back to customers with better products and services, continuously enhancing its corporate value. In Djibouti, GCL Group and Poly Group are jointly planning to build a 10 million ton oil refining project and a 15 million ton LNG project with China Merchants Group, China Communications Construction Corporation, and others For liquefaction projects, 1 million kilowatt power generation projects, seawater desalination and salt chemical projects, GCL Group has been ranked among the top 500 enterprises in the new energy industry for consecutive years. It is a comprehensive energy operation service provider with distinctive industrial characteristics and outstanding development advantages. Reporter: Zhu, in the maintenance and upkeep of electric buses, do you have any experience to share with peers? In the process of improving the cable intermediate joint, the technical personnel have learned from the experience and technology of external units, laying a solid foundation for the comprehensive promotion of this new technology. At the current level, the strategic concept of building the "New Silk Road Economic Belt" and the "21st Century Maritime Silk Road" has been clearly proposed. Xinjiang is positioned as the "core area of the Silk Road Economic Belt", occupying Xinjiang, with its geographical and energy advantages, It will play a pivotal role in this strategic vision. According to data, Sunac Power's solar products include grid connected photovoltaic inverters, off grid photovoltaic controls, inverter equipment and grid connected photovoltaic system monitoring, distribution convergence, and other products, which can meet various types of photovoltaic modules, photovoltaic applications, and grid connection requirements,

*****Project Case*****
☆ Donghua University Information Hub Building
☆ Yunnan Dayao County People's Hospital
☆ * Inspection and Quarantine Center for Low Voltage Electrical Appliances and Complete Switchgear
☆ Shanghai Zhabei Power Plant
☆ Shanghai UnionPay Information Center
☆ Taiyuan South Railway Station Project
☆ Jinan Shengjian Electric Motor Factory
☆ * Shipbuilding Heavy Industry Group Co., Ltd
☆ New Campus of Yunnan University for Nationalities
☆ China Railway Electrification Group Co., Ltd. Material Department Beijing Shanghai Electrification Renovation Project


NY5000-E Energy Efficiency Management Host NY5000-E
NY5000-E Energy Efficiency Management Host NY5000-E
NY5000-EWelcome to contact Tang GongWe mainly specialize in fire equipment power monitoring, motor protection controllers, multifunctional meters, rail mounted energy meters, electrical fire monitoring, intelligent lighting control, and intelligent control devices for switchgear