LaMo-09 series nine index water quality testing instrument kit

NegotiableUpdate on 07/24
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The LaMo-09 series nine index water quality testing instrument kit is divided into standard and extended types. The basic type can complete: turbidity, chromaticity pH、 Oxygen consumption, residual chlorine and chlorine dioxide, total bacterial count, total coliform bacteria, visible substances to the naked eye, odor and taste routine testing for 9 indicators; Expanded testing has added 28 drinking water indicators, including fluoride, ammonia nitrogen, aluminum, iron, manganese, copper, zinc, cyanide, chloride, sulfate, nitrate, total hardness, ozone, total chlorine, boron, and chromium (hexavalent). The LaMo-09 series nine index water quality testing instrument kit has obvious advantages: the instrument has good comprehensiveness, and DPD effervescent tablets are used for * * agent testing. Microbial testing does not require a clean room, and the culture medium does not need to be refrigerated. The cultivation temperature can be at room temperature, and the operation is simple without the need for personnel.

Product Details

LaMo-09Series Nine Indicator Water Quality Testing Instrument Kit,Divided into standard and extended models,Standard configurationCan complete: turbidity, chromaticitypHOxygen consumption, residual chlorine and chlorine dioxide, total bacterial count, total coliform bacteria, visible to the naked eye, odor and taste routine9indextesting;expandtypeAdded:Cyanide, ammonia nitrogen, nitrate, nitrite, sulfate, alkalinity, boron, phenol, anionic surfactants, aluminum, iron, manganese, copper, zinc, chromium (hexavalent) pH、 Residual chlorine, total chlorine, ozone, chlorine dioxide, fluoride, chloride, total hardness, etc28termTesting of drinking water indicators.

LaMo-09The advantages of the series kit are obvious: good instrument comprehensiveness, * * agent detection adoptsDPDeffervescent tablet.microorganismTesting does not require a clean room, and the culture medium does not need to be refrigerated. The cultivation temperature can be at room temperature, and the operation is simple without the need for personnel.

Product Introduction

TCSCType turbidity * * agent detector

Testing items:Chromaticity, turbiditypH, * * remaining dosage(Residual chlorine/chlorine dioxide

Product Features


Good comprehensiveness, one machine can detect all * * agents and sensory indicators

The testing method fully complies with the national standard requirements

DPD effervescent tablet reagent, fast dissolution, accurate quantification

Standard configuration includes 1.0NTU turbidity standard solution, which is consistent with the national standard limit to ensure detection accuracy

Integrated flip shading cover to prevent stray light from entering, avoiding loss and misuse

Limit type sampling bottle, controllable sampling speed, ensuring quantitative addition of water sample

Waterproof rating IP67, completely waterproof and dustproof

Certified Public Accountant (CPA)

SMART-COD type

permanganometryCODMeter

Test item: Oxygen consumption(COD)

Product Features

The detection method is the acid potassium permanganate titration method, which is consistent with the national standard method

**High degree, with a liquid absorption division of 0.001mL

Long life plunger pump, capable of up to 5 million cycles

Using photoelectric sensors to accurately measure liquid absorption without calibration

Pre set titration program, no user programming required

Equipped with a human-machine dialogue interface, convenient for inputting commands

Automatically complete cleaning and lubrication to avoid cross contamination

Large size color touch screen, directly displaying oxygen consumption concentration (mg/L)

Can store 1000 sets of data and browse historical data

11001 colony count detection kit

Test item: Total bacterial count

Product Features

The detection method is the plate counting method, which is consistent with the national standard method

Liquid finished culture medium without refrigeration

The culture dish has a special coating for curing

After mixing the water sample with the culture medium, pour it directly into the culture dish to ensure uniform inoculation and solidification

The vaccination process is simple and fast, without the need for a clean room

Independent packaging to avoid contamination

• Clear bacterial colonies that can be directly counted

4-3616 Total Coliform Detection Kit

Test item: Total coliform bacteria

Product Features

The detection method is the multi tube fermentation method, which is consistent with the national standard method

Specially designed sterile sampling bag containing sodium thiosulfate, which can remove chlorine from water and ensure that the test results are not affected by chlorine

Finished sheet culture medium, pre packaged in sterile sealed culture bottles, stored at room temperature without refrigeration

The vaccination process is simple and fast, simply pour the water sample from the sterile sampling bag into a sealed tube, without the need for a clean room

• Intuitively determine the presence or absence of bubbles based on color and presence of bubbles

1741 pH meter

Test item: pH

Product Features

The detection method is the glass electrode method, which is consistent with the national standard method

Dual display function of numbers and bar charts

Equipped with three-point calibration function, the instrument can obtain accurate measurement results within the measurement range

Contains three types of calibration buffer tablets: 4, 7, and 10, without the need for self configuring reagents

Has data storage and browsing historical data functions

SMART-3 Multi Parameter Water Quality Rapid Tester

Testing items:Cyanide, ammonia nitrogen, nitrate, nitrite, sulfate, alkalinity, boron, phenol, anionic surfactants, aluminum, iron, manganese, copper, zinc, chromium (hexavalent) pH、 Residual chlorine, total chlorine, ozone, chlorine dioxide, fluoride, chloride, total hardness, etc

Product Features

The testing method meets the requirements of the national standard

Good comprehensiveness, one can detect 23 indicators of drinking water, and all come with supporting reagents, without the need for self configuration

100 standard curves have been pre-set, and 25 curves can be customized as needed

Common detection items can be placed at the top without the need for retrieval

DPD effervescent tablet reagent, fast dissolution, accurate quantification

• Integrated flip over shading cover to prevent stray light from entering, avoiding loss and misuse

Limit type sampling bottle, controllable sampling speed, ensuring quantitative addition of water sample

Waterproof rating IP67, completely waterproof and dustproof

Certified Public Accountant (CPA)

4053 arsenic detection kit

Testing item: Arsenic

Product Features

The detection method is arsenic spot method, which is consistent with the national standard method

Fast detection speed, only 15 minutes to obtain the detection results

Multiple color spoons for convenient and timely addition of reagents

Compare colors to obtain detection results

1756 fluoride detector

Test item: Fluoride

Product Features

The detection method is ion selective electrode method, which is consistent with the national standard method

Tablet reagents, one tablet at a time, no need for configuration

Dual display function of numbers and bar charts

Fast detection, less than 1 minute

Has data storage and browsing historical data functions

Automatic calibration function

4482 Total Hardness Titration Kit

Testing item: Total hardness

Product Features

The detection method is ethylenediaminetetraacetic acid disodium titration, which is consistent with the national standard method

Finished reagents can be directly added without the need for self configuration

4503 chloride titration kit

Test item: Fluoride

Product Features

The detection method is silver nitrate volumetric method, which is consistent with the national standard method

Finished reagents can be directly added without the need for self configuration

LaMo-09 series nine index water quality testing instrument kit

Nine water quality indicators and limits

**Agent name

National standard limit and water contact time

Factory water limit

Excess in factory water

Excess water at the end of the pipeline network

Chlorine gas and free chlorine preparations (free chlorine)

at least30min

4

0.3

0.05

Monochloroamine (total chlorine,mg/L

at least120min

3

0.5

0.05

Chlorine dioxide(ClO2mg/L

at least30min

0.8

0.1

0.02

Testing items

*National standard limit

International limits

Total number of bacterial colonies(CFU/mL

500

100

Total coliform microbiota(MPN/100mLperhapsCFU/100mL

-

not detectable

Chromaticity (Platinum Cobalt Chromaticity Unit)

20

15

Turbidity(NTU

3When limited by water sources and purification technology conditions5

1When limited by water sources and purification technology conditions3

pH

Not less than6.5 And not greater than9.5

Not less than6.5 And not greater than8.5

Oxygen consumption(mg/L

5

3Water source limitation, oxygen consumption of raw water

Smell and taste

No abnormal odor or peculiar smell

No abnormal odor or peculiar smell

Visible to the naked eye

not have

not have

Note: ★ Water quality indicators and limits for small-scale centralized and decentralized water supply in rural areas

Extracted fromGB5749-2006Sanitary Standards for Drinking Water

TCSC turbidity detector

Good comprehensiveness

Single instrument for detecting chromaticity, turbidity pH 、 Residual chlorine, total chlorine, chlorine dioxide, and ozone are equivalent to six instruments

test method

Fully comply with national standard requirements, turbidity: scattering method - Formazine; Chromaticity: Platinum cobalt colorimetric method; Residual chlorine, chlorine dioxide, ozone: DPD spectrophotometric method; PH: Standard buffer solution colorimetric method

Range and Resolution

Chromaticity: Range: 0-1000cu, Resolution: 1cu

Turbidity: Range: 0.00~4000NTU, three-stage automatic range

(0.00~10.99NTU、11.0~109.9NTU、110~4000NTU)

Resolution: 0.01NTU (0.00~10.99NTU), 0.1NTU

(11.0~109.9NTU)、1NTU(110~4000NTU)

Accuracy: ± 0.05NTU (0-2.5NTU), ± 2% (2.5-100NTU)

PH: Range: 6.2-8.8, Resolution: 0.1

Residual chlorine and total chlorine: range: 0.00-4.00mg/L, resolution: 0.01mg/L

Chlorine dioxide: range: 0.00~7.60mg/L, resolution: 0.01mg/L

Ozone: Range: 0.00~3.00mg/L, Resolution: 0.01mg/L

reaction time

<2s

Average turbidity signal

The function of averaging 2, 5, or 10 measurement values can be selected or disabled

Automatic shutdown

You can set automatic shutdown times of 5, 10, and 30 minutes by yourself

monitor

LCD display with backlight function

Data Storage

500 sets

Standard reagents

Turbidity standard solution: 0.0NTU, 1.0NTU, 10.0NTU Fumalazine standard solution (1 bottle each); PH reagent: flake reagent (100 times); Residual chlorine, total chlorine, chlorine dioxide, ozone reagent: DPD effervescent tablet reagent (100 times/type)

Add sample bottle

Limit type sample bottle, controllable water sample addition speed, ensuring quantitative addition of water sample

Light shielding cover

Integrated flip shading cover to prevent stray light from entering, avoiding loss and misuse

power supply

Rechargeable lithium battery, USB interface, AC/DC converter

USB interface

Mini B interface, used for data transmission and charging

authentication

CPA certification, CE certification

Waterproof grade

IP67, Completely waterproof and dustproof

Standard configuration

Host (1 unit), standard reagent (1 set), sample bottle (1), data cable (1 piece), power adapter (1 piece), wiping cloth (1 piece)

SMART-COD potassium permanganate titration COD analyzer

test method

Acidic potassium permanganate titration method, consistent with the national standard method

range

0-5.000mg/L (expandable range)

Division of liquid absorption

0.001mL

accuracy

0.2%FS

repeatability

1.0%(2%FS),0.2%(2%FS~100%FS)

pump performance

Long life plunger pump, capable of up to 5 million cycles

Quantitative liquid absorption

Initial position photoelectric sensor, accurate quantification, precise and fast, calibration free

Drip rate

The drip speed is adjustable, with two levels of fast drip and slow drip, which can be freely switched

Titration preset

Can set the liquid addition volume, quickly add, and ensure that the temperature meets the requirements

automatic control

Automation of titration process

Titration Procedure

Pre set titration program, no user programming required

Operation interface

Equipped with a human-machine dialogue interface, convenient for inputting commands

anti-pollution

Automatically complete cleaning and lubrication to avoid cross contamination

The results show

Directly display droplet volume and oxygen consumption concentration (mg/L)

display

Large size color touch screen

Data Storage

Can store 1000 sets of data, including date, time, titration volume, and test results

Power saving mode

Specific no operation time can be set by oneself, automatically entering power-saving mode

Standard configuration

Host (1 unit), finished reagents (100 times), dual constant temperature magnetic stirrer (with heating function), conical flask (100mL, 2 units), volumetric flask (100mL, 2 units), measuring cylinder (50mL, 1 unit), pipette (5mL, 1 unit, including nozzle)

1741 pH meter

pH

Range: 0.00~14.00; Accuracy: ± 2% FS; Resolution: 0.01

temperature

Range: 0 ℃ to 65.0 ℃; Resolution: 0.1 ℃

Automatic calibration

Equipped with three-point calibration function, the instrument can obtain accurate measurement results within the measurement range

Buffer

Contains three types of calibration buffer tablets: 4, 7, and 10, without the need for self configuring reagents

display

LCD display with dual display function of numbers and bar charts

automatic temperature compensation

Equipped with temperature automatic compensation function, not affected by environmental temperature, stable degree

Data Storage

25 sets of data

Other functions

Equipped with low battery indicator light and automatic shutdown setting function without operation

11001 colony count detection kit

test method

Plate counting method, consistent with the national standard method

operating environment

The vaccination process is simple and fast, without the need for a clean room

culture medium

Liquid finished culture medium without refrigeration

petri dish

Featuring a special coating that cures in 40 minutes

Uniform solidification of vaccination

After mixing the water sample with the culture medium, pour it directly into the culture dish to ensure uniform inoculation and solidification

Packaging method

Packaged separately, processed to avoid contamination

culture method

Incubator or room temperature

Culture time

48 hours

Colony count

Clearly visible colonies, count directly

Basic configuration

Total Count (11001): 25 reagents each, 25 disposable sterile droppers

4-3616 Total Coliform Detection Kit

test method

Multi tube fermentation method, consistent with the national standard method

operating environment

The vaccination process is simple and fast, without the need for a clean room

sampling bag

Aseptic sampling bag containing sodium thiosulfate, which can remove chlorine from water and ensure that the test results are not affected by chlorine

Cultivation reagents

Finished sheet-like culture medium, pre placed in sterile sealed culture bottles

Reagent storage

Room temperature storage, no need for refrigeration

Simple operation

Pour the water sample from the sterile sampling bag into a sealed tube without any processing required

culture method

Incubator or room temperature

Culture time

48 hours (room temperature dark light cultivation)/24 hours (incubator)

Result judgment

After cultivation, visually determine the presence or absence of bubbles based on color changes and the presence of bubbles

Basic configuration

Total Coliform 25 times, 25 sterile sampling bags

SMART3 Multi Parameter Water Quality Rapid Tester

wavelength range

428nm,525nm,568nm,635nm

wavelength accuracy

±2% FS

Wavelength selection

auto select

spectral bandwidth

10nm

Photometric measurement range

-2~2A

photometric accuracy

± 0.001AU at 1.0AU

photometric accuracy

± 0.00 * * U at 1.0AU

reading modes

%Transmittance, absorbance, concentration, and predetermined program testing

light source

4 LED light sources

detector

Four silicon photodiodes with interference filters

Sample Cell

25mm round test tube, 10mm square UDV tube

Stored calibration curve

100 pieces, with matching finished reagents, can be used directly

Custom Curve

25 items, require self preparation of reagents

custom list

Common detection items can be customized as sequences for easy operation

Finished reagents

The testing items come with matching original reagents and do not require self configuration

Light shielding cover

Integrated flip shading cover to prevent stray light from entering, avoiding loss and misuse

Data Storage

500 sets of data including time and date

display

Large LCD backlit display screen with multiple languages including Chinese and English

Operation keys

6 waterproof buttons

power supply

Lithium ion battery, USB interface, AC/DC converter

BATTERY LIFE

Can perform 380-1000 tests

Waterproof grade

IP67, Completely waterproof and dustproof

authentication

Certified Public Accountant (CPA)

Standard configuration

Host (1 unit), colorimetric bottles (6 pieces), reagents (1 set), data cable (1 piece)

UDV adapter (1 piece), wiping cloth (1 piece)

4053 arsenic detection kit

test method

Arsenic spot method (national standard method), inorganic As+3 and As+5 are converted during the detection process

Transformed into arsine gas, which can cause the test strip to change from yellow to brown, and then

Compare with the color chart to determine the concentration of arsenic

detection time

15min

range

<0.004, 0.004, 0.008, 0.010, 0.012, 0.014, 0.016

0.020, 0.025, 0.030, 0.050, 0.085, 0.100, 0.150, 0.175

0.200、0.300、0.400 mg/L

resolution

0.001 mg/L

detection result

Visual inspection results of color chart, easy to operate

Card slot bottle cap

The bottle cap is equipped with a card slot, which can fix the test strip and suspend it above the water sample for sufficient reaction

medicine spoon

Multiple color spoons for convenient and timely addition of reagents

Number of tests

50 times

Standard configuration

Reagent (1 set), medicine spoon (3 pieces), color chart (1 piece), sample bottle (2 pieces)

Card slot bottle cap (2 pieces), illustrated manual (1 book)

1756 fluoride detector

test method

Ionic selective electrode method, consistent with the national standard method

detection time

<1min

Finished reagents

Tablet reagents, one tablet at a time, no need for configuration

range

0.0~10 mg/L

resolution

0.1 mg/L

Data Storage

25 sets of data with browsing history function

display

LCD display with dual display function of numbers and bar charts

Other functions

Automatic shutdown, low battery prompt, and automatic calibration function

Standard configuration

Reagent (1 set), host (1 unit), sample cup (1 unit), crushing rod (1 unit)

4482 Total Hardness Titration Kit

test method

Ethylenediaminetetraacetic acid disodium titration method, in compliance with national standard requirements

range

0~600 mg/L

accuracy

4 mg/L (calculated as CaCO3)

Number of tests

50 times

Standard configuration

Reagent (1 set), glass graduated colorimetric tube (25 mL, 1 tube), direct reading dripFixed device (1 piece), pipette (0.5mL, 1 tube)

4503 chloride titration kit

test method

Silver nitrate volumetric method, in compliance with national standard requirements

range

0~400 mg/L

accuracy

4 mg/L (as Cl)-Calculation)

Number of tests

50 times

Standard configuration

Reagent (1 set), glass graduated colorimetric tube (15 mL, 1 tube), direct reading dripFixed device (1 piece)