LaMo-09Series Nine Indicator Water Quality Testing Instrument Kit,Divided into standard and extended models,Standard configurationCan complete: turbidity, chromaticitypHOxygen consumption, residual chlorine and chlorine dioxide, total bacterial count, total coliform bacteria, visible to the naked eye, odor and taste routine9indextesting;expandtypeAdded:Cyanide, ammonia nitrogen, nitrate, nitrite, sulfate, alkalinity, boron, phenol, anionic surfactants, aluminum, iron, manganese, copper, zinc, chromium (hexavalent) pH、 Residual chlorine, total chlorine, ozone, chlorine dioxide, fluoride, chloride, total hardness, etc28termTesting of drinking water indicators.
LaMo-09The advantages of the series kit are obvious: good instrument comprehensiveness, * * agent detection adoptsDPDeffervescent tablet.microorganismTesting does not require a clean room, and the culture medium does not need to be refrigerated. The cultivation temperature can be at room temperature, and the operation is simple without the need for personnel.
Product Introduction
TCSCType turbidity * * agent detector
Testing items:Chromaticity, turbiditypH, * * remaining dosage(Residual chlorine/chlorine dioxide)
Product Features
Good comprehensiveness, one machine can detect all * * agents and sensory indicators
The testing method fully complies with the national standard requirements
DPD effervescent tablet reagent, fast dissolution, accurate quantification
•Standard configuration includes 1.0NTU turbidity standard solution, which is consistent with the national standard limit to ensure detection accuracy
•Integrated flip shading cover to prevent stray light from entering, avoiding loss and misuse
Limit type sampling bottle, controllable sampling speed, ensuring quantitative addition of water sample
•Waterproof rating IP67, completely waterproof and dustproof
•Certified Public Accountant (CPA)
SMART-COD type
permanganometryCODMeter
Test item: Oxygen consumption(COD)
Product Features
•The detection method is the acid potassium permanganate titration method, which is consistent with the national standard method
•**High degree, with a liquid absorption division of 0.001mL
Long life plunger pump, capable of up to 5 million cycles
Using photoelectric sensors to accurately measure liquid absorption without calibration
•Pre set titration program, no user programming required
•Equipped with a human-machine dialogue interface, convenient for inputting commands
•Automatically complete cleaning and lubrication to avoid cross contamination
•Large size color touch screen, directly displaying oxygen consumption concentration (mg/L)
•Can store 1000 sets of data and browse historical data
11001 colony count detection kit
Test item: Total bacterial count
Product Features
•The detection method is the plate counting method, which is consistent with the national standard method
•Liquid finished culture medium without refrigeration
The culture dish has a special coating for curing
•After mixing the water sample with the culture medium, pour it directly into the culture dish to ensure uniform inoculation and solidification
•The vaccination process is simple and fast, without the need for a clean room
•Independent packaging to avoid contamination
• Clear bacterial colonies that can be directly counted
4-3616 Total Coliform Detection Kit
Test item: Total coliform bacteria
Product Features
The detection method is the multi tube fermentation method, which is consistent with the national standard method
•Specially designed sterile sampling bag containing sodium thiosulfate, which can remove chlorine from water and ensure that the test results are not affected by chlorine
•Finished sheet culture medium, pre packaged in sterile sealed culture bottles, stored at room temperature without refrigeration
The vaccination process is simple and fast, simply pour the water sample from the sterile sampling bag into a sealed tube, without the need for a clean room
• Intuitively determine the presence or absence of bubbles based on color and presence of bubbles
1741 pH meter
Test item: pH
Product Features
The detection method is the glass electrode method, which is consistent with the national standard method
•Dual display function of numbers and bar charts
•Equipped with three-point calibration function, the instrument can obtain accurate measurement results within the measurement range
•Contains three types of calibration buffer tablets: 4, 7, and 10, without the need for self configuring reagents
•Has data storage and browsing historical data functions
SMART-3 Multi Parameter Water Quality Rapid Tester
Testing items:Cyanide, ammonia nitrogen, nitrate, nitrite, sulfate, alkalinity, boron, phenol, anionic surfactants, aluminum, iron, manganese, copper, zinc, chromium (hexavalent) pH、 Residual chlorine, total chlorine, ozone, chlorine dioxide, fluoride, chloride, total hardness, etc
Product Features
•The testing method meets the requirements of the national standard
Good comprehensiveness, one can detect 23 indicators of drinking water, and all come with supporting reagents, without the need for self configuration
100 standard curves have been pre-set, and 25 curves can be customized as needed
•Common detection items can be placed at the top without the need for retrieval
•DPD effervescent tablet reagent, fast dissolution, accurate quantification
• Integrated flip over shading cover to prevent stray light from entering, avoiding loss and misuse
Limit type sampling bottle, controllable sampling speed, ensuring quantitative addition of water sample
•Waterproof rating IP67, completely waterproof and dustproof
•Certified Public Accountant (CPA)
4053 arsenic detection kit
Testing item: Arsenic
Product Features
•The detection method is arsenic spot method, which is consistent with the national standard method
Fast detection speed, only 15 minutes to obtain the detection results
Multiple color spoons for convenient and timely addition of reagents
•Compare colors to obtain detection results
1756 fluoride detector
Test item: Fluoride
Product Features
•The detection method is ion selective electrode method, which is consistent with the national standard method
•Tablet reagents, one tablet at a time, no need for configuration
•Dual display function of numbers and bar charts
•Fast detection, less than 1 minute
•Has data storage and browsing historical data functions
•Automatic calibration function
4482 Total Hardness Titration Kit
Testing item: Total hardness
Product Features
•The detection method is ethylenediaminetetraacetic acid disodium titration, which is consistent with the national standard method
Finished reagents can be directly added without the need for self configuration
4503 chloride titration kit
Test item: Fluoride
Product Features
•The detection method is silver nitrate volumetric method, which is consistent with the national standard method
•Finished reagents can be directly added without the need for self configuration
LaMo-09 series nine index water quality testing instrument kit
Nine water quality indicators and limits
|
**Agent name |
National standard limit and water contact time |
Factory water limit |
Excess in factory water |
Excess water at the end of the pipeline network |
|
Chlorine gas and free chlorine preparations (free chlorine) |
at least30min |
4 |
≥ 0.3 |
≥ 0.05 |
|
Monochloroamine (total chlorine,mg/L) |
at least120min |
3 |
≥ 0.5 |
≥ 0.05 |
|
Chlorine dioxide(ClO2,mg/L) |
at least30min |
0.8 |
≥ 0.1 |
≥ 0.02 |
|
Testing items |
*National standard limit |
International limits |
|
Total number of bacterial colonies(CFU/mL) |
500 |
100 |
|
Total coliform microbiota(MPN/100mLperhapsCFU/100mL) |
- |
not detectable |
|
Chromaticity (Platinum Cobalt Chromaticity Unit) |
20 |
15 |
|
Turbidity(NTU) |
3When limited by water sources and purification technology conditions5 |
1When limited by water sources and purification technology conditions3 |
|
pH |
Not less than6.5 And not greater than9.5 |
Not less than6.5 And not greater than8.5 |
|
Oxygen consumption(mg/L) |
5 |
3Water source limitation, oxygen consumption of raw water |
|
Smell and taste |
No abnormal odor or peculiar smell |
No abnormal odor or peculiar smell |
|
Visible to the naked eye |
not have |
not have |
Note: ★ Water quality indicators and limits for small-scale centralized and decentralized water supply in rural areas
Extracted fromGB5749-2006Sanitary Standards for Drinking Water
TCSC turbidity detector
|
Good comprehensiveness |
Single instrument for detecting chromaticity, turbidity pH 、 Residual chlorine, total chlorine, chlorine dioxide, and ozone are equivalent to six instruments |
|
test method |
Fully comply with national standard requirements, turbidity: scattering method - Formazine; Chromaticity: Platinum cobalt colorimetric method; Residual chlorine, chlorine dioxide, ozone: DPD spectrophotometric method; PH: Standard buffer solution colorimetric method |
|
Range and Resolution |
Chromaticity: Range: 0-1000cu, Resolution: 1cu Turbidity: Range: 0.00~4000NTU, three-stage automatic range (0.00~10.99NTU、11.0~109.9NTU、110~4000NTU) Resolution: 0.01NTU (0.00~10.99NTU), 0.1NTU (11.0~109.9NTU)、1NTU(110~4000NTU) Accuracy: ± 0.05NTU (0-2.5NTU), ± 2% (2.5-100NTU) PH: Range: 6.2-8.8, Resolution: 0.1 Residual chlorine and total chlorine: range: 0.00-4.00mg/L, resolution: 0.01mg/L Chlorine dioxide: range: 0.00~7.60mg/L, resolution: 0.01mg/L Ozone: Range: 0.00~3.00mg/L, Resolution: 0.01mg/L |
|
reaction time |
<2s |
|
Average turbidity signal |
The function of averaging 2, 5, or 10 measurement values can be selected or disabled |
|
Automatic shutdown |
You can set automatic shutdown times of 5, 10, and 30 minutes by yourself |
|
monitor |
LCD display with backlight function |
|
Data Storage |
500 sets |
|
Standard reagents |
Turbidity standard solution: 0.0NTU, 1.0NTU, 10.0NTU Fumalazine standard solution (1 bottle each); PH reagent: flake reagent (100 times); Residual chlorine, total chlorine, chlorine dioxide, ozone reagent: DPD effervescent tablet reagent (100 times/type) |
|
Add sample bottle |
Limit type sample bottle, controllable water sample addition speed, ensuring quantitative addition of water sample |
|
Light shielding cover |
Integrated flip shading cover to prevent stray light from entering, avoiding loss and misuse |
|
power supply |
Rechargeable lithium battery, USB interface, AC/DC converter |
|
USB interface |
Mini B interface, used for data transmission and charging |
|
authentication |
CPA certification, CE certification |
|
Waterproof grade |
IP67, Completely waterproof and dustproof |
|
Standard configuration |
Host (1 unit), standard reagent (1 set), sample bottle (1), data cable (1 piece), power adapter (1 piece), wiping cloth (1 piece) |
SMART-COD potassium permanganate titration COD analyzer
|
test method |
Acidic potassium permanganate titration method, consistent with the national standard method |
|
range |
0-5.000mg/L (expandable range) |
|
Division of liquid absorption |
0.001mL |
|
accuracy |
0.2%FS |
|
repeatability |
1.0%(2%FS),0.2%(2%FS~100%FS) |
|
pump performance |
Long life plunger pump, capable of up to 5 million cycles |
|
Quantitative liquid absorption |
Initial position photoelectric sensor, accurate quantification, precise and fast, calibration free |
|
Drip rate |
The drip speed is adjustable, with two levels of fast drip and slow drip, which can be freely switched |
|
Titration preset |
Can set the liquid addition volume, quickly add, and ensure that the temperature meets the requirements |
|
automatic control |
Automation of titration process |
|
Titration Procedure |
Pre set titration program, no user programming required |
|
Operation interface |
Equipped with a human-machine dialogue interface, convenient for inputting commands |
|
anti-pollution |
Automatically complete cleaning and lubrication to avoid cross contamination |
|
The results show |
Directly display droplet volume and oxygen consumption concentration (mg/L) |
|
display |
Large size color touch screen |
|
Data Storage |
Can store 1000 sets of data, including date, time, titration volume, and test results |
|
Power saving mode |
Specific no operation time can be set by oneself, automatically entering power-saving mode |
|
Standard configuration |
Host (1 unit), finished reagents (100 times), dual constant temperature magnetic stirrer (with heating function), conical flask (100mL, 2 units), volumetric flask (100mL, 2 units), measuring cylinder (50mL, 1 unit), pipette (5mL, 1 unit, including nozzle) |
1741 pH meter
|
pH |
Range: 0.00~14.00; Accuracy: ± 2% FS; Resolution: 0.01 |
|
temperature |
Range: 0 ℃ to 65.0 ℃; Resolution: 0.1 ℃ |
|
Automatic calibration |
Equipped with three-point calibration function, the instrument can obtain accurate measurement results within the measurement range |
|
Buffer |
Contains three types of calibration buffer tablets: 4, 7, and 10, without the need for self configuring reagents |
|
display |
LCD display with dual display function of numbers and bar charts |
|
automatic temperature compensation |
Equipped with temperature automatic compensation function, not affected by environmental temperature, stable degree |
|
Data Storage |
25 sets of data |
|
Other functions |
Equipped with low battery indicator light and automatic shutdown setting function without operation |
11001 colony count detection kit
|
test method |
Plate counting method, consistent with the national standard method |
|
operating environment |
The vaccination process is simple and fast, without the need for a clean room |
|
culture medium |
Liquid finished culture medium without refrigeration |
|
petri dish |
Featuring a special coating that cures in 40 minutes |
|
Uniform solidification of vaccination |
After mixing the water sample with the culture medium, pour it directly into the culture dish to ensure uniform inoculation and solidification |
|
Packaging method |
Packaged separately, processed to avoid contamination |
|
culture method |
Incubator or room temperature |
|
Culture time |
48 hours |
|
Colony count |
Clearly visible colonies, count directly |
|
Basic configuration |
Total Count (11001): 25 reagents each, 25 disposable sterile droppers |
4-3616 Total Coliform Detection Kit
|
test method |
Multi tube fermentation method, consistent with the national standard method |
|
operating environment |
The vaccination process is simple and fast, without the need for a clean room |
|
sampling bag |
Aseptic sampling bag containing sodium thiosulfate, which can remove chlorine from water and ensure that the test results are not affected by chlorine |
|
Cultivation reagents |
Finished sheet-like culture medium, pre placed in sterile sealed culture bottles |
|
Reagent storage |
Room temperature storage, no need for refrigeration |
|
Simple operation |
Pour the water sample from the sterile sampling bag into a sealed tube without any processing required |
|
culture method |
Incubator or room temperature |
|
Culture time |
48 hours (room temperature dark light cultivation)/24 hours (incubator) |
|
Result judgment |
After cultivation, visually determine the presence or absence of bubbles based on color changes and the presence of bubbles |
|
Basic configuration |
Total Coliform 25 times, 25 sterile sampling bags |
SMART3 Multi Parameter Water Quality Rapid Tester
|
wavelength range |
428nm,525nm,568nm,635nm |
|
wavelength accuracy |
±2% FS |
|
Wavelength selection |
auto select |
|
spectral bandwidth |
10nm |
|
Photometric measurement range |
-2~2A |
|
photometric accuracy |
± 0.001AU at 1.0AU |
|
photometric accuracy |
± 0.00 * * U at 1.0AU |
|
reading modes |
%Transmittance, absorbance, concentration, and predetermined program testing |
|
light source |
4 LED light sources |
|
detector |
Four silicon photodiodes with interference filters |
|
Sample Cell |
25mm round test tube, 10mm square UDV tube |
|
Stored calibration curve |
100 pieces, with matching finished reagents, can be used directly |
|
Custom Curve |
25 items, require self preparation of reagents |
|
custom list |
Common detection items can be customized as sequences for easy operation |
|
Finished reagents |
The testing items come with matching original reagents and do not require self configuration |
|
Light shielding cover |
Integrated flip shading cover to prevent stray light from entering, avoiding loss and misuse |
|
Data Storage |
500 sets of data including time and date |
|
display |
Large LCD backlit display screen with multiple languages including Chinese and English |
|
Operation keys |
6 waterproof buttons |
|
power supply |
Lithium ion battery, USB interface, AC/DC converter |
|
BATTERY LIFE |
Can perform 380-1000 tests |
|
Waterproof grade |
IP67, Completely waterproof and dustproof |
|
authentication |
Certified Public Accountant (CPA) |
|
Standard configuration |
Host (1 unit), colorimetric bottles (6 pieces), reagents (1 set), data cable (1 piece) UDV adapter (1 piece), wiping cloth (1 piece) |
4053 arsenic detection kit
|
test method |
Arsenic spot method (national standard method), inorganic As+3 and As+5 are converted during the detection process Transformed into arsine gas, which can cause the test strip to change from yellow to brown, and then Compare with the color chart to determine the concentration of arsenic |
|
detection time |
15min |
|
range |
<0.004, 0.004, 0.008, 0.010, 0.012, 0.014, 0.016 0.020, 0.025, 0.030, 0.050, 0.085, 0.100, 0.150, 0.175 0.200、0.300、0.400 mg/L |
|
resolution |
0.001 mg/L |
|
detection result |
Visual inspection results of color chart, easy to operate |
|
Card slot bottle cap |
The bottle cap is equipped with a card slot, which can fix the test strip and suspend it above the water sample for sufficient reaction |
|
medicine spoon |
Multiple color spoons for convenient and timely addition of reagents |
|
Number of tests |
50 times |
|
Standard configuration |
Reagent (1 set), medicine spoon (3 pieces), color chart (1 piece), sample bottle (2 pieces) Card slot bottle cap (2 pieces), illustrated manual (1 book) |
1756 fluoride detector
|
test method |
Ionic selective electrode method, consistent with the national standard method |
|
detection time |
<1min |
|
Finished reagents |
Tablet reagents, one tablet at a time, no need for configuration |
|
range |
0.0~10 mg/L |
|
resolution |
0.1 mg/L |
|
Data Storage |
25 sets of data with browsing history function |
|
display |
LCD display with dual display function of numbers and bar charts |
|
Other functions |
Automatic shutdown, low battery prompt, and automatic calibration function |
|
Standard configuration |
Reagent (1 set), host (1 unit), sample cup (1 unit), crushing rod (1 unit) |
4482 Total Hardness Titration Kit
|
test method |
Ethylenediaminetetraacetic acid disodium titration method, in compliance with national standard requirements |
|
range |
0~600 mg/L |
|
accuracy |
4 mg/L (calculated as CaCO3) |
|
Number of tests |
50 times |
|
Standard configuration |
Reagent (1 set), glass graduated colorimetric tube (25 mL, 1 tube), direct reading dripFixed device (1 piece), pipette (0.5mL, 1 tube) |
4503 chloride titration kit
|
test method |
Silver nitrate volumetric method, in compliance with national standard requirements |
|
range |
0~400 mg/L |
|
accuracy |
4 mg/L (as Cl)-Calculation) |
|
Number of tests |
50 times |
|
Standard configuration |
Reagent (1 set), glass graduated colorimetric tube (15 mL, 1 tube), direct reading dripFixed device (1 piece) |