E10Micro high pressure reactor
E10Micro high pressure reactorDetails
For high temperature and high pressure testing, it is a difficult problem to meet both "experiment" and "operation convenience". The technical personnel of Beijing Century Senlang Experimental Instrument Company have successfully developed the A-type double line sealing device through cooperation with major universities and metal processing technology. It has static sealing, no leakage, no exposed rotating parts, and is reliable. The kettle body and heater can be completely separated, which facilitates the disassembly of the reaction kettle, improves work efficiency, and provides chemical workers with a miniature catalytic hydrogenation reaction kettle.
ForLaboratory researchers, like those in enterprises, are under tremendous pressure from the market, and time cost becomes the key to success or failure. Especially for research and development institutions in industries such as pharmaceuticals and chemicals, time becomes the key to success or failure.It is necessary to explore the optimal reaction conditions in a short period of time, shorten the research and development time as much as possible, and ensure that the new product has a competitive advantage.EasyChemThe emergence of, realizing for industries such as pharmaceuticals and chemicalsfilterConditions, process selectionOptimization of reaction conditionsWaiting for research to provide better options, multifunctionalEasyChemofTechnical assurance greatly shortens the research and development time of the project, making it a must-have tool for you to strategize and win from thousands of miles away.
E10Micro high pressure reactorFeatures
At the end of the day,Top in soft drive magnetic stirring,Mixing in both directions,No exposed rotating parts, reliable,High speed stability, eliminateAccidental leakage of low boiling point gas vapor or flammable gas poses a danger to the motor circuit
At the end of the day,AType double line sealSolved the problem of traditional reactor sealingLeakage problem, prevent toxic gas leakage.
At the end of the day,Sound and light alarm - over temperatureAutomatically cut off the heating power supply,Added a layer of protection to the reactor
At the end of the day,Unique design needle valve - reliable quality,Solved the sealing problem of traditional valvesproblem
At the end of the day,explosion-proof valve--------The sentinel at the forefront has added another layer to the experimental environment
At the end of the day,Timed response - set time, unmanned, saving valuable time for testing personnel
At the end of the day,Internal temperature control - Temperature control
At the end of the day,High torque motor ensures high-speed and stable mixing
At the end of the day,Stainless steel pressure gauge - shock resistant, durableCorrosion and durability
At the end of the day,KType thermocouple-------Ensuring the accuracy of the measurement
At the end of the day,Module heating-------Fast heating rate
At the end of the day,Independently developed temperature control system------Preventing temperature overshoot increases the success of the experiment
At the end of the day,Carbon fiber insulation material-----Energy-saving and environmental protection
At the end of the day,Separation of kettle body and control system----Convenient disassembly and improved work efficiency
At the end of the day,Unique heat dissipation design-------Preventing local overheating increases the service life of the equipment
At the end of the day,carefully selected materials-----The processing of forging materials for the kettle body eliminates the source of irrelevant factors
At the end of the day,Professional processing technology-----The rigorous processing standards and strict execution procedures have forged the essential elements
At the end of the day,Precise testing equipment------Eliminate the growth of irrelevant factors in the bud stage
At the end of the day,Low-noise design-----Provides a quiet research environment
At the end of the day,Reasonable seismic design-----Ensured smooth and high-speed operation of the entire machine
At the end of the day,Multi functional design-----Meets various experimental requirements
At the end of the day,Exquisite exterior designDisrupting the traditional operation method of reaction vessels, making scientific research and life easier
(EasyChemReaction kettleEAll series reactors can be upgraded to:EasyChemReaction kettleASeries touch control terminal, real-time display during curves, automatic collection of reaction data)
E10Micro high pressure reactorTechnical Specifications
model |
E10 |
type |
Desktop high temperature and high pressure |
heat |
Module heating |
temperature range |
Room temperature to 350 ° C |
stirring speed |
0 rpmUp to 1200 rpm infinite speed regulation |
material |
Standard 316 |
volume |
10 m |
Mixing form |
Top entry soft drive magnetic coupling mechanical stirring (anchor or paddle) |
pressure range |
Standard configuration: 10Mpa |
|
control unit
|
LCD screen display: temperature, speed, reaction time. |
Timer time 0-999H |
Positive and negative bidirectional stirring |
outer dimensions |
360 mmx 340 mm x 650 mm |
power configuration |
200 - 240 V AC,50 - 60 Hz |
:
Beijing Century Senlang Experimental Instrument Co., Ltd