Harvard Model 22 Precision Injection Pump

NegotiableUpdate on 02/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Characteristics of precision injection pump PHD22; High stability accuracy and reproducibility, low flow rate. The precision injection pump PHD22 has good fluidity and versatility

Product Details

Product Introduction

Introduction to Harvard Model 22 Precision Injection Pump Instrument:

Characteristics of precision injection pump PHD22; High stability accuracy and reproducibility, low flow rate. The precision injection pump PHD22 has good fluidity and versatility

Technical parameters of precision injection pump PHD22:

In programming operation mode, the above tasks can be connected to functional programs to simplify your automation projects.

Technical Specifications

Type: microprocessor driven infusion pump

Stability accuracy ± 0.35%

Reproducing accuracy ± 0.05%


Syringe size:

Small value 0.5 μ l

Large value 140 ml


Current Speed:

Small value 0.0001 μ l/hr

Maximum value 220.82 ml/min

Non volatile memory stores all settings

RS-232 RJ11-4 plug

TTL 9-pin D-Sub. plug

Average straight-line thrust standard 50 lbs

High injection pressure 66 lbs

Drive motor 1.8 ° stepper motor

The motor drive control can be controlled by a microprocessor in micro steps ranging from 1/2 to 1/32

The number of steps in front of the motor for each rotation of the guide screw ranges from 800 to 12800

The forward distance of each motor step is 0.082 μ m/step


Step speed:

27.3 seconds per step

416.7 microseconds/step

Propulsion Movement Speed:

小 0.18 μm / min

190.676 mm/min

Power 65 W, 0.5A fuse

Voltage range: 95 to 130V AC, 60Hz, 220 to 260V AC, 50Hz, optional

Dimensions, height x width x length 15.9 x 22.8 x 27.9 cm (6.3 x 9 x 11 in)

Weight 4.5kg (10 lb)


Main features of precision injection pump PHD22:


Harvard Instruments' precision injection pumps are characterized by their wide variety and high precision. Due to the numerous models and accessories of the precision injection pump PHD22, they cannot be listed one by one. To further understand the product information related to precision injection pump PHD22, please contact Spectral Quality Analysis Testing Technology


Characteristics of Precision Injection Pump PHD22:


• Stable accuracy and reproducibility accuracy

• Flow rate

• Liquidity and universality

Forty years ago, Harvard Instruments improved the principle of guided screw and manufactured an injection pump. Since then, tens of thousands of Harvard pumps have earned the honor of reliable research partners in every important laboratory worldwide. The precision injection pump PHD22 series can provide you with slow flow rate, high precision, smooth liquid flow, programmable operation performance from the keyboard, and the precision injection pump PHD22 is easy to use.


High stability accuracy and repeatability accuracy


Precision injection pump PHD22 welded steel chassis, machined Derlin ™ Components, reinforced guide rods, and electronic devices can provide a stable accuracy of 0.35% and a reproducibility accuracy of 0.05%.


Low flow rate


The new micro stepper motor and control software of precision injection pump PHD22 provide low speed, which can be reduced to 0.0001 microliters per hour. It is still quiet, so it will not interfere with your experimental project.


versatility


Having a precision injection pump PHD22 can meet the needs of simple injection, infusion and aspiration, or programmable operation.

1. Only for injection: This injection pump is suitable for situations that require high precision and low flow rate, but do not require liquid suction or programming operations. Do you still need suction and programmable operation in the future? This injection pump, which is only used for injection, can be upgraded.

2. Injection/suction: The precision injection pump PHD22 injection/suction type injection pump has the same performance as the injection only model (mentioned above) and can also suction (re inject).

3. Programmable operation: The Harvard Precision Injection Pump PHD22 Programmable Operation Injection Pump has programming functions and is also very easy to use. This infusion pump can store four programs, each with 10 steps of operation. The program is stored in non-volatile memory. No other infusion pump can provide you with this level of control and flexibility. Programmable operational infusion pumps can also be programmed using Symphony, which is Harvard's Windows ™ Injection pump management software.



easy to use

The bright and easy to read dual row fluorescent display of precision injection pump PHD22 can be conveniently read from outside the laboratory. The target injection volume button makes it easy to deliver the pre-set injection volume. Even with only a small number of personnel participating in the work, the ergonomic "self-locking" release mechanism can make the work easier and there will never be a situation where the syringe forgets to lock. The numeric keypad utilizes the familiar "telephone" layout scheme.



upgrade

What we offer is an upgradable infusion pump. If you purchase an injection/aspiration precision injection pump PHD22 and later find that you need a programmable operation type, you can upgrade it. You can save a lot of money compared to buying a brand new infusion pump.



Programming instructions


The programming function of this precision injection pump PHD22 provides great programming capability for the experiment. In programming operation mode or when the infusion pump is activated by a signal from an external device, this precision infusion pump PHD22 can perform the following tasks at a preset time:


-Start or stop infusion

-Change the infusion direction (injection suction)

-Change the flow rate

-Deliver precise delivery volume and stop the machine

-Suspend work

-Increase or decrease the flow rate