The TUD500 ultrasonic flaw detector is a portable industrial non-destructive testing instrument that can quickly, conveniently, without damage, and accurately detect, locate, evaluate, and diagnose various defects (cracks, inclusions, pores, etc.) inside the workpiece. It can be used in both laboratories and engineering sites. This instrument can be widely used in manufacturing, steel metallurgy, metal processing industry, chemical industry and other fields that require defect detection and quality control. It is also widely used in in-service safety inspection and life assessment in aerospace, railway transportation, boiler pressure vessel and other fields.

Product Details

Era TUD500 Ultrasonic Flaw Detectorcharacteristic

5.7 "High brightness color VGA (640x480) TFT LCD display screen,Higher resolutionFine graphics, optional colors, and adjustable brightness

※ * Grayscale B-scan display, suitable for simple TOFD applications

※ Added inner and outer diameter surface correction function, AWS D1.1, DAC, AVG quantitative function

Continuous dynamic recording and massive storage

Both USB and RS232 interfaces are available for free communication

12 bit AD conversion with higher system resolution

※ CompliantEuropean standard En12668-1Requirement

Era TUD500 Ultrasonic Flaw DetectorTechnical Parameter

A-scan and B-scan simultaneously display grayscale B-scan, making defects intuitive and distinguishable

Project

Indicator

PRODUCT INFORMATION

Product weight (kg)

<2.0

Product dimensions (mm)

300 × 180 × 57 (without light shield)

Working temperature (℃)

-10 ~ +50

Storage temperature (℃)

-20 ~ +60

language

English, Chinese

Probe connection

LEMO or BNC

Battery capacity (mAh)

Polymer battery 2 × 3.7V 5000mAh

Battery working time (h)

8

Fast charging time (h)

About 4.5

The power adapter

Input 100-240~50/60Hz

Output 9V DC/3 A~4A

display

Color transmission TFT, 640x480

Basic

Measurement unit

mm 、 inch 、m s

Scanning range (mm)

Zero interface incidence~10000

Speed regulation (m/s)

600 ~ 16000

Probe delay(m s )

0.000 ~ 750.000

Display delay(m s )

-20 ~ +3400

way of working

Single probe, dual probe, transmission

Waveform display mode

A-scan display, grayscale B-scan display, AB scan simultaneous display

pulse generator

Pulse form

Simulate square waves

Transmitting power supply (V)

200, 400, 600, 1000

Emission pulse width (ns)

75, 100-500

Probe damping (Ω)

50, 100, 200, 500

Transmitting repetition frequency (Hz)

10 ~ 1000

receiver

Gain (dB)

0 ~ 110

Total bandwidth (MHz)

0.1~15 (-3dB)

detection mode

Positive half wave, negative half wave, full wave, RF

Vertical linear error

± 2%

Amplifier accuracy (dB)

± 1

Inhibition (%)

Screen height of 0-80

Sampling rate (MHz)

80

Emission crosstalk suppression (dB)

Greater than 80

Blind zone after pulse emission (μ s)

3.3~10 (related to launch)

Dynamic range (dB)

100

Instantaneous resolution (dB)

32

Time base linearity

Not greater than ± 0.5% of the full screen width.

Sensitivity margin

≥ 62dB

Measurement and others

Measure the gate

2 independent measuring gates

detection

Edge, peak value

Gate measurement

The amplitude, sound path, depth, projection, etc. of the echo

freeze

Freezing methods include: full freezing, peak value, comparison, envelope, etc

AVG equivalent calculation

Automatically calculate defect equivalent based on defect echo and AVG curve

DAC defect quantification

Evaluate defects based on defect echoes and DAC curves

Gate logic

Off, measurement, incoming wave alarm, lost wave alarm

Gate alarm

Off, instant, hold for. 2s, hold for. 5s, hold for 1s, hold for 2s, latch

Alarm buzzer

Close, open

Data management, communication, and printing

Data Storage

50 channel records of flaw detection parameters

1000 waveform diagrams

(including 980 A-scan waveforms and 20 B-scan waveforms)

Dynamic waveform of 4x2000 frames

data management

Implement storage, viewing, and playback operations for channels, waveforms, and dynamic records

All of the above can be stored locally or on a USB drive

communication

Communicate with PC through USB interface

print

Print flaw detection report

output interface

USB OTG interface

USB 2.0 Device and PC Communication Interface

USB 2.0 Host connected to USB flash drive or printer

Micro RS232 interface