Elab TOC/DWT dual-mode oxidation total organic carbon analyzer

Product Details

Instrument characteristics
1. Dual oxidation mode - both combustion oxidation and UV wet oxidation modes are available simultaneously, providing complete protection for various applications;
2. Fast measurement speed - measuring TIC in less than 1.5 minutes; The determination of TC combustion oxidation method is less than 1.5 minutes, and the UV wet oxidation method is less than 2.5 minutes;
3. The heated IC inorganic carbon reaction cell eliminates the tailing of sample peaks, and this technology has obtained a national patent!
4. The use of a total reflection ultraviolet strong oxidation reaction cell has excellent system adaptability and can completely convert the sample without the need to add other oxidation reagents, avoiding blank interference caused by the addition of oxidation reagents during the measurement process. This technology has obtained a national invention patent!
5. Unique electronic refrigeration module and membrane dehydration technology, using excellent dehydration technology to ensure the dehydration efficiency of the entire system. This technology has obtained national patents!
6. Using the same pyrolysis combustion system to measure liquid (water), solid (garbage and soil) samples without replacing any hardware, this technology has obtained a national invention patent!
7. Unique air path buffering design - ensures excellent reproducibility of sample measurement results.
8. Configure the total nitrogen module to simultaneously measure the total carbon and total nitrogen content.
Technical parameters:


Measurement method

Combustion oxidation/UV wet oxidation non dispersive infrared detection method

detector

NDIR

TOCmeasuring range

0—30000mg/kg

TOCDetermination of reproducibility

≤1.5%

TNmeasuring range

0—10000mg/kg

TNDetermination of reproducibility

≤1.5%

Maximum salt tolerance

100g/L

dehydration

Three stage dehydration - electronic dual refrigeration module dehydration and membrane dehydration device

catalyst

Pt/CeO2catalyst

Gas requirements

Oxygen: ≥ 99.995%

Injection volume

Liquid: 10-6000 μ l

Power requirements