EPS three-phase fire emergency power supply

NegotiableUpdate on 04/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Note: The output circuit can be installed in the emergency power supply cabinet according to the design requirements

Product Details

EPS三相消防应急电源(图1)
EPS三相消防应急电源(图2)
EPS三相消防应急电源(图3)
Note: The output circuit can be installed in the emergency power supply cabinet according to the design requirements.
design parameters
serial number model output power
(KVA)
battery voltage
(V)
charging current
(A)
Number of batteries
(Section)
Host size (mm)
Length (Depth) x Width x Height
1 ZN-D-2.2kVA-S 2.2 192/216 3 16/18 400×600×1500
2 ZN-D-3.7kVA-S 3.7 192/216 3 16/18 450×600×1600
3 ZN-D-5.5kVA-S 5.5 192/216 3/5 16/18 500×750×1700
4 ZN-D-7.5kVA-S 7.5 192/216 3/5 16/18 600×800×2000
5 ZN-D-11kVA-S 11 192/216 3/5 16/18 600×800×2000
6 ZN-D-15kVA-S 15 216/324 3/5/10 18/27 600×800×2000
7 ZN-D-18.5 KVA 18.5 216/324 3/5/10 18/27 600×800×2000
8 ZN-D-18.5kVA-S 20 324 3/5/10 27 600×800×2000
9 ZN-D-22kVA-S 22 324 3/5/10 27 600×800×2000
10 ZN-D-25kVA-S 25 324 5/10 27 600×800×2000
11 ZN-D-30kVA-S 30 324/492 5/10 27/41 600×800×2000
12 ZN-D-37kVA-S 37 324/492 5/10 27/41 600×800×2000
13 ZN-D-45kVA-S 45 324/492 5/10 27/41 600×800×2000
14 ZN-D-55kVA-S 55 324/492 10/15 27/41 600×800×2000
15 ZN-D-75kVA-S 75 324/492 10/15 27/41 600×800×2000
16 ZN-D-90kVA-S 90 492 10/15 41 600×800×2000
17 ZN-D-100kVA-S 100 492 10/15 41 600×800×2000
18 ZN-D-110kVA-S 110 492 10/15 41 600×800×2000
19 ZN-D-132kVA-S 132 492 15/20 41 600×800×2000
20 ZN-D-160kVA-S 160 492 15/20 41 600×800×2000
21 ZN-D-185kVA-S 185 492 15/20 41 600×800×2000
22 ZN-D-200kVA-S 200 492 15/20 41 600×800×2000

Note: The size and quantity of the cabinet may be adjusted appropriately depending on the emergency time and internal components.
Model/Rated Capacity ZN-D-2.2-200kVA-S
mains input phase number Three phase four wire+PE
voltage 380V±15%
frequency 50Hz±5%
emergency output capacity 2.2kVA-1000kVA, Parallel operation
voltage 220V/AC ± 5% 380V/AC three-phase four wire ± 5% PE
Voltage stability rate ±5%
waveform sine wave
Waveform distortion THD ≤ 3% (0-100% linear load)
conversion efficiency ≥90%
overload capacity ≤ 120% rated current working normally
>120% rated current, normal output stops after about 10 seconds
When the rated current exceeds 150% or the load is short circuited, the current limiting output will stop after about 1 second
battery Maintenance free sealed battery
Rated battery voltage 192V 216V 324V 492V
standby time Standard 90 minutes, (can be configured according to design requirements)
Charging time Can be filled within 24 hours
Convert time ≤ 5 seconds (special requirements can be designed for "zero" switching)
protect Emergency overload protection and output short circuit protection; Battery reverse connection protection; Battery undervoltage protection, etc
call the police Battery undervoltage, battery connection failure, charger failure, continuous overload, inverter failure, etc
ambient temperature -40℃-55℃
ambient humidity ≤90%RH, Not condensing
altitude ≤2500m
noise
Adapt to load Suitable for various loads, especially for inductive and inductive capacitive mixed loads
Door opening and wire entry method Front door double opening, rear door double opening, bottom inlet and outlet line (standard type).