Beijing Haidian District Xiyuan Nuclear Industry Standardization Research Institute (Headquarters)
Beijing Hongtong Huarui Electric Co., Ltd
chinahonto@126.com
Beijing Haidian District Xiyuan Nuclear Industry Standardization Research Institute (Headquarters)
![]() ![]() Note: If there are any changes to the above data during product updates, please refer to the latest data provided by our company. |
| serial number | model | output power (KVA) |
battery voltage (V) |
charging current (A) |
Number of batteries (Section) |
Host size (mm) Length (Depth) x Width x Height |
| 1 | ZN/D-0.5 KVA | 0.5 | 48 | 3 | 4 | 300×500×800 |
| 2 | ZN/D-1 KVA | 1 | 48 | 3 | 4 | 300×500×800 |
| 3 | ZN/D-1.5 KVA | 1.5 | 48 | 3 | 4 | 400×600×1200 |
| 4 | ZN/D-2 KVA | 2 | 48 | 3 | 4 | 400×600×1200 |
| 5 | ZN/D-3 KVA | 3 | 48/96 | 3 | 4 | 450×750×1500 |
| 6 | ZN/D-4 KVA | 4 | 192/216 | 3/5 | 16/18 | 450×750×1500 |
| 7 | ZN/D-5 KVA | 5 | 192/216 | 3/5 | 16/18 | 500×750×1700 |
| 8 | ZN/D-6 KVA | 6 | 192/216 | 3/5 | 16/18 | 450×750×1700 |
| 9 | ZN/D-7 KVA | 7 | 192/216 | 3/5 | 16/18 | 450×750×1700 |
| 10 | ZN/D-8 KVA | 8 | 192/216 | 3/5 | 16/18 | 600×800×2000 |
| 11 | ZN/D-9 KVA | 9 | 192/216 | 3/5 | 16/18 | 600×800×2000 |
| 12 | ZN/D-10 KVA | 10 | 192/216 | 3/5 | 16/18 | 600×800×2000 |
| 13 | ZN/D-15 KVA | 15 | 192/216 | 3/5 | 16/18 | 600×800×2000 |
| Specification Model | ZN/D 0.5-15KVA | |
| mains input | phase number | Single phase (L-N+PE) |
| voltage | 220V±15% | |
| frequency | 50Hz±5% | |
| emergency output | voltage | 220V/AC±5% |
| waveform | sine wave | |
| Waveform distortion | THD ≤ 5% (0-100% linear load) | |
| conversion efficiency | ≥90% | |
| overload capacity | ≤ 120% rated current working normally >120% rated current, normal output stops after about 5 seconds >120% rated current or load short circuit, limited current output stops after about 1 second |
|
| storage battery | type | Sealed maintenance free lead-acid battery |
| rated voltage | DC48V 192V 216V | |
| standby time | National standard 90 minutes (can be configured according to design requirements) | |
| Charging time | Can be filled within 24 hours | |
| Convert time | Standard ≤ 5s special "zero" switching | |
| protect | Emergency overload protection and output short circuit protection; Battery reverse connection protection; Battery undervoltage protection, etc | |
| call the police | Battery undervoltage, battery connection failure, charger failure, continuous overload, inverter failure, etc | |
| ambient temperature | -40℃-55℃ | |
| ambient humidity | ≤90%RH, Not condensing | |
| altitude | ≤2500m | |
| noise | ||