DKDIL/DKTMA series low-temperature thermal expansion instrument/thermal mechanical analyzer - with a minimum measurable temperature of 4K. The DKDIL/DKTMA low-temperature thermal expansion/thermal mechanical system adopts original imported European thermal expansion displacement measurement technology and components

Product Details


DKDIL/DKTMAseriesLow temperature thermal expansion instrument/thermomechanical analyzer


——Minimum measurable temperature 4K




DKDIL/DKTMAThe low-temperature thermal expansion/thermomechanical system adopts original imported European thermal expansion displacement measurement technology and components. It can analyze and measure the physical properties of materials at a low temperature of -269 ℃, meeting the needs of military industry, aerospace industry, glass industry, ceramic industry, high-tech ceramic sintering, metal metallurgy powder industry, new material research and development, automotive industry, polymer industry, etc. Thermal expansion is mainly applied in the research and quality control of materials such as solids, liquids, powders, and pastes. The system complies with international standards including DIN 51045, ASTM E831, ASTM E 228, and ASTM D 3386.



DIL Technical ParametersTemperature range:-263... RT/220 ℃ (direct cooling low-temperature system without liquid helium refrigeration)









-150... 400 ℃ (liquid nitrogen)










High temperature furnace body (RT-1200/1600/1750/2400 ℃)
Measurement system:Single pole, double poleSample length:
0<L≤50 mmSample diameter:
7 mm/12mm/14mm/20mm/Customized
Measurement range:
0-5000 μm (±2500μm)
Resolution:0.125 nm/digitAtmosphere:Oxidation, reduction, inert atmosphere
CTMA Technical ParametersOperation mode:Linear expansion, body expansion, compression, three-point bending, film and fiber stretchingTemperature range:

-263... RT/220 ℃ (direct cooling low-temperature system without liquid helium refrigeration)










-150... 400 ℃ (liquid nitrogen)










Room temperature .1750℃
Test scope:±2
Mm; automatic detection of sample length
Maximum load:3500mNAbsolute resolution:±0.2 nmTemperature scanning rate:0~100℃/minMaximum cooling rate:
50/100 ℃/min
Sample size:
H 20mm* Φ10mm真空度:
10E-2 mbar.
Test atmosphere:Dynamic (flowing) or staticAnalysis software:Chinese and English operating softwareCan be used in conjunction with Fourier transform infrared spectrometer FTIR, MS