E-mail
scitop@126.com
-
Phone
13602461893
-
Address
301, Building C, Jiade Technology Park, No. 27 Yayingshi Road, Huangpu District, Guangzhou City
Guangzhou Saituo Instrument Technology Co., Ltd
scitop@126.com
13602461893
301, Building C, Jiade Technology Park, No. 27 Yayingshi Road, Huangpu District, Guangzhou City
Equipped with automatic buffer recognitionTheAbsoluteandRelativeORP measurement and automatic temperature compensation functions ensure measurement accuracy.
The pH/ORP controller is a robust microprocessor-based instrument designed for laboratory and process control applications, housed in a waterproof 1/8DIN enclosure.
The system displays pH, ORP, temperature, and relay status on a large LCD screen.
The pH/ORP300 microprocessor executes a self diagnostic program every time it is turned on, providing you with basic information about the stability of the instrument. This model is equipped with 2 control relays. All control relays are programmable and lag driven.
Specifications:
|
model |
05802-12 |
05802-14 |
05802-15 |
|
pH |
|||
|
scope |
-2.00 |
||
|
to 16.00 pH |
resolution |
||
|
0.01 |
pHprecision±0.1% |
||
|
±1 digitrecognized |
pH |
||
|
buffer solutionUS |
(4.01, 7.00, 10.01) orNIST (4.00, 6.86, 9.18)pHtemperature compensationManual/Auto |
||
|
-10.0℃ |
0.0to 120.0℃pH |
||
|
Buffer temperature range℃ |
to 60.0 |
||
|
PHElectrode offset recognition |
100 |
||
|
mV at pH 7.00 |
+108.3 mV/-91.7 mV at pH 6.8612 |
||
|
pH |
Electrode slope recognition |
||
|
30% |
|||
|
at pH 4.00, 4.01, 9.18, 10.01 |
input impedance>10 |
||
|
Calibrate endpoint sensor |
0.1Yes |
||
|
temperature |
scope0.3-10.0 |
||
|
to 120.0℃resolution℃ |
precision±℃temperature sensor(Users can choose) |
||
|
Thermistor: 10k ohm at 25℃ |
, |
resistor |
|
|
(PT1000) Or manuallycontroller: |
control type |
Two |
|
|
ON/OFF contro |
|||
|
Two |
ON/OFF contro |
||
|
relay output |
( |
||
|
Limited resistance load |
)5Aat 115VAC or 2.5A at 220VAC5A |
||
|
at 115VAC or 2.5A at 220VAC |
|||
|
ORP |
Absolute mV |
||
|
scope |
-1999 |
||
|
to 1999 mV |
resolution1mVprecision |
||
|
± |
|||
|
0.1% |
± |
||
|
1 digit |
ORP |
||
|
Relative mV |
scope |
||
|
-2999 |
to 2999 mVresolution |
||
|
1 |
mV |
||
|
precision |
|||
|
± |
0.1% |
||
|
± |
1 digit |
||
|
4-20 |
mA outputoutput range |
||
|
4 |
to 20 mA (isolated) |
||
|
Output scale |
user |
||
programmable
|
Maximum load |
500 |
|
ohm |
accurate±0.03mAisolation voltage500VDCroutineKeys |
|
Audio |
feedback in all keyspower supply100VACto 240VAC , 50/60HzEnvironmental temperature range0.0to 50.04℃boxIP65, |
|
1/8DIN case, depth 90mm |