The CYY-3 high-frequency infrared metal element analysis system is a comprehensive element analyzer. This instrument adopts a high-frequency induction furnace combined with an infrared carbon sulfur analysis system, which can quickly and accurately determine the elements in various materials such as plain carbon steel, high, medium and low alloy steel, cast iron, gray cast iron, ductile iron, alloy cast iron, various ferroalloys, ferrosilicon, manganese iron, nickel iron, chromium iron, rare earth metals, coke, coal, slag, catalyst, ore, etc. The instrument burns samples through a high-frequency induction furnace, determines the content of C and S elements by infrared analysis, and determines the content of Mn, P, Si, Cr, Ni, Mo and other elements by photoelectric colorimetry. The analysis system consists of two parts: a high-frequency infrared carbon sulfur analyzer and a computer multi-element analyzer.

1、 Main technical parameters:
1. Analysis method: Infrared analysis method is used for carbon and sulfur analysis; Other multiple elements are measured using the photoelectric colorimetric method.
2. Measurement range: (This instrument can detect many elements, taking carbon, sulfur, silicon, manganese, and phosphorus in black metals as an example)
C: 0.00001-10.0000% (expandable up to 99.999%), S: 0.00001-0.3500% (expandable up to 99.999%)
Si:0.010~6.000%、 Mn:0.010~18.00%、 P:0.0005~2.000%
3. Measurement accuracy: Carbon meets ISO9556-94 standard, sulfur meets ISO4935-94 standard, and other elements meet GB/T223-88 standard
4. Electronic balance: weighing range 0-100g, reading accuracy 0.0001g
5. Computer: Mainstream models, well-known brands (can be covered by national warranty)
2、 High frequency combustion system
1. The high-frequency furnace has a high output power (greater than 6KVA), high efficiency, and adjustable power, suitable for combustion analysis of various samples, with a wide range of testing materials.
2. The whole machine adopts high-end solenoid valves, high-frequency ceramic power tubes, etc., and key components are made of high-quality components to improve stability and reliability.
3. The high-frequency control circuit is controlled by a computer program to achieve automatic detection of solenoid valves, automatic overcurrent and outdated alarms, etc.
4. The dust in the pipeline is discharged by the automatic cleaning system, which improves the stability and accuracy of the measurement.
5. Selection of key components: Ceramic high-power tube, using 6KVA ceramic high-power tube, with high output power, suitable for sample analysis of various materials. High precision flow meters can analyze stable air flow and provide more stable and reliable analysis results. Metal filter, using 0.4 micron ultra microporous metal filter to ensure complete separation of dust and gas.
3、 Main features:
1. Windows color Chinese operating system, with intuitive display, convenient operation, and easy mastery.
2. The software has powerful functions, strong reliability and anti-interference ability of the whole machine, and low failure rate.
3. The software has complete functions, including channel selection, data statistics, result correction, release curve display comparison, system monitoring, system diagnosis, and more than forty other functions.
4. Display carbon and sulfur analysis results in different color images, dynamically display real-time data and release curves, allowing the operator to see the combustion at a glance.
5. There are more than ten channels for analyzing carbon and sulfur elements, which can be freely combined and have a wide range of choices.
6. The whole machine is designed with modularity, the hardware is particularly simple, the failure rate is low, the stability is good, and the test results are accurate and reliable.
7. The driving circuit design is unique, reasonable, and the signal is stable.
8. The electronic balance is automatically connected and can measure samples without quantity.
9. Selection of key components:
Detector: High precision pyroelectric infrared detector is used.
Module power supply: adopting professional design, integrated linear power supply, stable performance, low failure rate.
Light source: Platinum resistor is used, which is not easily oxidized, has a long service life, stable luminescence, and good spectral characteristics.
Testing pool body: processed with special materials and techniques.
Motor: Controlled by a microcontroller, the operating speed is more stable and reliable, and it can work continuously for 100000 hours without any faults.
10. The system has established a powerful database for storing and querying analysis result data and working curves, which is very convenient for modifying data and adding or deleting curves.
11. The testing software is fully functional and can completely replace various manual writing tasks in traditional laboratories. It can also input any testing conditions to query historical data and print all element testing reports at once.
12. The computer adopts "intelligent dynamic tracking" and "non-linear regression of standard curve" technologies for multiple elements, and has computer software control detection programs.
13. Using computer control and data processing, it can store multiple curves and perform curve correction, with functions such as power-off data protection.
14. Establishing a dedicated database for instruments to analyze and modify data can expand the variety and content range of measured elements.
15. The instrument software program is developed using the popular assembly language JAVA, which is easy to understand, simple, and fast to operate.
16. The testing software is fully functional and has a channel space for detecting 108 elements.
17. The instrument has stable performance, easy maintenance, and a long service life.
18. The modular design of the entire analysis system allows for the selection of materials for testing.