-
E-mail
Amy@ultrainst.com
-
Phone
13437720684
-
Address
Room 807, Unit 2, Building 1, Aotou Oriental Xintiandi Building, Dayawan District, Huizhou City
Huizhou Daya Bay Aite Instrument Co., Ltd
Amy@ultrainst.com
13437720684
Room 807, Unit 2, Building 1, Aotou Oriental Xintiandi Building, Dayawan District, Huizhou City
AVP-30DThe Type I automatic saturation vapor pressure tester uses small sample pressure gauges. Due to the vapor pressure of the sample bomb The length and volume are proportional reductions of the volume of a standard Reid pressure sample bullet(respectively 60%and 30%)Can be faster And the correct measurement of Reid's saturated vapor pressure. And in the model“D”, indicating that the size of the oxygen bomb is the standard The prescribed“Demisize.”. Instrument Features 1. Small size,The instrument width is only 400mmCan be placed on the test bench. 2. A high-precision pressure sensor that automatically measures the saturation vapor pressure of Reid using a unique vibration method. Unique fast interface design, easy to install and disassemble. 3.Instrument calibration The instrument can easily apply mercury column(mercury)The pressure gauge is used to calibrate the air pressure sensor. Additionally, the instrument leaves the factoryOnce all adjustments have been made, there is usually no need for further adjustments. Product Parameters Applicable standardsISO 3007, ASTM D323, IP69 etc. GB/T 8017 Scope of testing0 to 196 kPa (2kgf/cm2) Test oxygen bomb Proportional small oxygen bomb, length is the original standard 66%The volume has decreased 31%Each oxygen bomb is equipped with a middle partUnique design“quick coupling”Connect the pressure tube to the test sensor. pressure sensor Test scope:0to 196kPa (2kgf/cm2) Linear and hysteresisAll posterior values are less than<0.3% Display screenBacklit display LCDAutomatically convert and display as needed KPaandkgf/cm2Two types of units Oscillation plate similar to“seesaw”The oscillating plate mechanism. each 6 Second, press±15 Shake the oxygen bomb up and down, and oxidize at a constant speed Reaction. Bath tubCompletely stainless steel with mixing,PT-100 Sensor, temperature control accuracy±0.1℃Heating power1.15kW. correction External standard mercury column is required(mercury)The pressure gauge is used to calibrate the air pressure sensor.(Optional parts) safety protection Water level protection design to avoid water level drop caused by heating. data output RS-232CInterface,1, can be connectedConnect to a computer or printer volume/WeightEmpty machine 50kgAfter adding water, about 85kg Environmental Requirements room temperature 0~40℃/ humidity 90%below(No condensation) Power demandmaximumpower 1.5kW(max.)