-
E-mail
Amy@ultrainst.com
-
Phone
13437720684
-
Address
Room 807, Unit 2, Building 1, Aotou Oriental Xintiandi Building, Dayawan District, Huizhou City
Huizhou Daya Bay Aite Instrument Co., Ltd
Amy@ultrainst.com
13437720684
Room 807, Unit 2, Building 1, Aotou Oriental Xintiandi Building, Dayawan District, Huizhou City
1、 Instrument features 1.The instrument adopts an integrated design, with flash point detection sensors, temperature sensors, and stirring blades assembled together on the testing arm, Convenient sample addition 2.An additional windproof protective cover is used to prevent the flame from extinguishing during gas ignition. 3.The instrument is equipped with a standard sample mode for testing the accuracy of the instrument. 4.Large screen color display, displaying different colors according to the progress of the experiment. 5.The instrument has a self checking function, which automatically stops running and displays the fault content in case of a malfunction. 6.Once the instrument catches fire, it automatically activates the fire extinguishing device and has a triple self-protection function. 7.Built in atmospheric pressure sensor, automatically corrects flash point value results. 8.The instrument is equipped with multiple testing modes, and users can also set their own testing conditions according to their needs. 9.Easy to operate, just select the test mode, input the expected flash point, and instrument implement come near tight check press illuminate treetop accurate self move advance go measure try , The experiment ends with a buzzing alarm and displays the test results. 10.Due to the incorrect setting of the expected flash point temperature during the experiment, the instrument can modify the expected flash point temperature at any time during the experiment ,thus Save time and save oil samples. 11. Equipped with both gas and electric ignition, it can be switched without the need to replace components, making it convenient. 12. Data processing, experimental results can be saved200The test results can be printed with an optional printer or throughUSB, RS-232Export data toLIMS.USBThe interface can be connectedUSBThe keyboard (optional) is used for inputting sample names, as well as Can connect flash memory to copy test parameters 13. Password protection, the experimental program has password protection function to prevent accidental operation 14. Lightweight integrated design, currently the smallest Binsky in the world in terms of volume-Martin closed cup flash point tester. 2、 Specification parameters model Integrated design, microprocessor control Test standards ISO2719,ASTM D93(A、B、CThree methods), GB/T261 Range 40 arrive 370℃ Test mode Standard mode, special mode, standard sample mode heating section BAND HEATER cooling system Forced air cooling (automatic cooling after flash point detection) display 5.7Inch color LCD display, the instrument is in standby, test, and cooling mode, with screens displayed separately Display different colors for easy identification of instrument status. stirring speed 100,250rpm(Automatically adjustable speed according to different testing methods) temperature sensor Equipped with stainless steel liningPT-100 Flash point detector CRCthermocouple ignition Gas and electric ignition Atmospheric pressure correction Automatic correction through built-in pressure sensor interface RS-232C = 1,USB=1 security setting The instrument stops running in the following situations, accompanied by a beep alarm and screen display (a)Above the preset flash point 20℃Above or exceeding 370℃time (b)Temperature Sensor Failure (c)Flash point detection sensor malfunction (d)Thermal fuse disconnected (e)The built-in battery has run out of power (f)The detection arm is not in place (g)Microcomputer loss of control (h)Mixing motor stops running (i)For special oil samples, the instrument can set the temperature arbitrarily as long as the expected flash point exceeds Starting from room temperature, the instrument gradually heats up according to the built-in temperature setting5℃perhaps10℃Detecting Flash Point, every5℃Set the ignition temperature. (j)Once a fire breaks out, it can be automatically extinguished Gas source (when using gas ignition) Liquefied gas or natural gas (not exceeding10kpa) power supply 220/240 VAC, 50/60Hz power maximum720W energy consumption 1The consumption of this experiment is about170Wh ambient temperature 0°C to 40°C External dimensions 230mm (W) × 470mm(D) × 390mm(H)17kg