Welcome Customer !

Membership

Help

Anhui Huaqiang Cable Co., Ltd
Custom manufacturer

Main Products:

foodequippro>Products

ZR-IS-KX-HA-FBRPJP-12 * 2 * 1.5 compensation cable

NegotiableUpdate on 01/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

ZR-IS-KX-HA-FBRPJP-12 * 2 * 1.5 compensating cable is a type of wire used to extend the cold end of a thermocouple to a location far away from high temperatures and where the temperature is relatively stable. Essentially, it is a thermocouple composed of two different metals. Within a certain temperature range, its thermoelectric properties are basically the same as those of the main thermocouple.

Product Details

ZR-IS-KX-HA-FBRPJP-12 * 2 * 1.5 compensation cableHaving a match with itthermocoupleA pair of insulated wires with the same nominal value of thermoelectric potential, used to connect a thermocouple andTemperature display controllerTables are used to compensate for the errors caused by temperature changes at their connection with thermocouples. Compensation wires (compensation cables) are suitable for single or multi-point connection of automatic temperature measuring instruments in industries such as power, metallurgy, petroleum, chemical, textile, as well as national defense, scientific research and other departments.

ZR-IS-KX-HA-FBRPJP-12 * 2 * 1.5 compensation cablePurpose:

The compensating wire and cable series products are suitable for temperature control systems in energy, metallurgy, petroleum, chemical and other industrial enterprises and research departments. It is used for connecting the cold end of temperature measuring instruments and between temperature measuring instruments. The heat-resistant type adopts fluoroplastic insulation and sheath, which has excellent heat resistance, waterproof, anti-corrosion, acid and alkali resistance, chemical resistance, wear resistance, aging resistance and non combustion performance.

Compensation wire and cable implementation standard: GB/T4989-2013 equivalent to IEC584.3.

ZR-IS-KX-HA-FBRPJP-12 * 2 * 1.5 compensation cableUsage characteristics:

type

bend radius

temperature

temperature

Unarmored

Armored

Fixed laying

Non fixed laying

一般型
There is "105" in the model
There is a "90" in the model
high-temperature type

6 times the outer diameter of the cable
10 times the outer diameter of the cable

12 times the outer diameter of the cable

≥-40℃

≥-60℃

≥-15℃

≥-20℃

≤70℃
≤105℃
≤90℃
≤250℃

ZR-IS-KX-HA-FBRPJP-12 * 2 * 1.5 compensation cable


project

code name

Code name meaning

project

code name

Code name meaning

model

SC

Equipped with S-index thermocouple compensation wire

Heat resistance level

70

The operating temperature is 70 ℃

RC

Equipped with R scale thermocouple compensation wire

105

The operating temperature is 105 ℃

NC

Equipped with N scale thermocouple compensation wire

200

The operating temperature is 200 ℃

NX

Equipped with N scale thermocouple compensation wire

250

The operating temperature is 250 ℃

KCA
KCB

Equipped with K-index thermocouple compensation wire

insulating material

V

polyvinyl chloride

KX

Equipped with K-index thermocouple compensation wire

Y

polyethylene

EX

Equipped with E-scale thermocouple compensation wire

B

polypropylene

JX

Equipped with J scale thermocouple compensation wire

F4

Polytetrafluoroethylene

T

Equipped with T-index thermocouple compensation wire

F46

Polychloroethylene propylene

Series Code

ZR

flame retardant cable

Jacket material

V

polyvinyl chloride

ia

Intrinsic safety cable

B

fiberglass

Use classification

G

general use

F4

Polytetrafluoroethylene

H

Heat resistant

F46

Polychloroethylene propylene

accuracy class

S

J confidentiality level

Shielding material

P

braided copper wire

P1

Tin plated copper wire weaving

/

Ordinary level

P2

Copper tape wrapping

P3

Aluminum/plastic composite film wrapping

Specifications


2 x cross-sectional area of conductor mm2

Types of Conductors


Single stranded conductor can be omitted

R

Multi stranded conductor

armor

22

steel tape armor

32

Fine steel wire armor






Technical Indicators:

Compensation wire model

Equipped with thermocouple

Thermocouple division number

Compensation wire and alloy wire

Insulation layer color

positive electrode

Negative level

positive electrode

Negative level

SC

Platinum rhodium 10 platinum thermocouple

S

SPC (Copper)

SNC (Copper Nickel)

red

green

RC

Rhodium 13 platinum thermocouple

R

RPC (copper)

RNC (Copper Nickel)

red

green

KCA

Nickel chromium nickel silicon thermocouple

K

KPCA (Iron)

KNCA (Copper Nickel)

red

blue

KCB

KPCB (Copper)

KNCB (Copper Nickel)

red

blue

KX

KPX (Nickel Chromium)

KNX (Nickel Silicon)

red

black

NC

Nickel chromium silicon nickel silicon thermocouple

N

NPC (Iron)

NNC (Copper Nickel)

red

gray

NX

NPX (Nickel Chromium Silicon)

NNX (Nickel Silicon)

red

gray

EX

Nickel chromium copper nickel thermocouple

E

EPX (Nickel Chromium)

ENX (Copper Nickel)

red

brown

JX

Iron copper nickel thermocouple

J

JPX (Iron)

JNX (Copper Nickel)

red

purple

TX

Copper copper nickel thermocouple

T

TPX (copper)

TNX (Copper Nickel)

red

white







Use classified protective layer colors

Use classification

Accuracy level and marking

sheath color

Ordinary level

J confidentiality level

Ordinary level

J confidentiality level

general use

G

/

S

black

grey

Heat resistant

H

/

S

black

yellow