ZC-KX200FPFP-1 * 2 * 1.5 compensation wireScope of Application
Ordinary compensating cables are widely used in metallurgy, chemical, petroleum, power generation, and scientific research departments where thermocouple methods are used to measure temperature. Used for connecting thermocouples and temperature display instruments.
ZC-KX200FPFP-1 * 2 * 1.5 compensation wireModel
Model, name, division number, and matching thermocouple type of ordinary compensating cable
| model | name | graduation mark | Matching thermocouple type | Insulation layer color | |
| positive electrode | negative electrode | ||||
| SC | Copper Copper Nickel 0.6 Compensation Cable | S | Platinum rhodium 10 platinum thermocouple | red | green |
| RC | Copper Copper Nickel 0.6 Compensation Cable | R | Platinum rhodium 13 platinum thermocouple | red | green |
| KCA | Iron Copper Nickel 22 Compensation Cable | K | Nickel chromium nickel silicon thermocouple | red | blue |
| KCB | Copper Copper Nickel 40 Compensation Cable | red | blue | ||
| KX | Nickel chromium 10 nickel silicon 3 extension cable | red | black | ||
| NC | Iron Copper Nickel 18 Compensation Cable | N | Nickel chromium silicon nickel silicon thermocouple | red | gray |
| NX | Nickel chromium 14 silicon nickel silicon extension cable | red | gray | ||
| EX | Nickel chromium 10 nickel silicon 45 extension cable | E | Nickel chromium copper nickel thermocouple | red | brown |
| JX | Iron Copper Nickel 45 Compensation Cable | J | Iron copper nickel thermocouple | red | purple |
| TX | Copper Copper Nickel 45 Compensation Cable | T | Copper copper nickel thermocouple | red | white |

ZC-KX200FPFP-1 * 2 * 1.5 compensation wireProduct Features
1. Thermal electromotive force and allowable value of ordinary compensating cables
| Compensation wire model | 100℃(μV) | 200℃(μV) | ||||
| Nominal value of thermoelectric potential | tolerance | Nominal value of thermoelectric potential | tolerance | |||
| Ordinary level | Precision grade | Ordinary level | Precision grade | |||
| SC or RC | 645 | ±60 | ±30 | 1440 | ±60 | -- |
| KCA or KX | 4095 | ±100 | ±60 | 8137 | ±100 | ±60 |
| KCB | 4095 | ±100 | ±60 | -- | -- | -- |
| NX or NC | 2774 | ±100 | ±60 | 5912 | ±100 | ±60 |
| EX | 6317 | ±200 | ±120 | 13419 | ±200 | ±120 |
| JX | 5268 | ±140 | ±85 | 10777 | ±140 | ±85 |
| TX | 4277 | ±60 | ±30 | 9285 | ±90 | ±48 |
Compensate for the reciprocating resistance of wires (cables)
| model | Reciprocating resistance at 20 ℃ ≤ Ω/m | |||
| 0.5mm2 | 1.0mm2 | 1.5mm2 | 2.5mm2 | |
| SC or RC | 0.10 | 0.05 | 0.03 | 0.02 |
| KCA | 1.40 | 0.70 | 0.47 | 0.28 |
| KCB | 1.04 | 0.52 | 0.35 | 0.21 |
| KX | 2.20 | 1.10 | 0.73 | 0.44 |
| NC | 1.50 | 0.75 | 0.50 | 0.30 |
| NX | 2.86 | 1.43 | 0.95 | 0.57 |
| EX | 2.50 | 1.25 | 0.83 | 0.50 |
| JX | 1.30 | 0.65 | 0.43 | 0.26 |