Flame retardant, fire-resistant, low smoke and halogen-free cables are suitable for power systems or control and monitoring circuits in subways, high-rise buildings, shopping malls, theaters, power stations, chemical factories, urban squares and other public utilities with AC rated voltage of 600/1000V and below.
Execution standards: Adopting enterprise standards and referring to GB9330-88 and GB/T12706-2002
Usage characteristics:
Flame retardant, fire-resistant, low smoke, and halogen-free cables are allowed to work for a long time at a temperature of 90 ℃
2. The laying temperature of flame-retardant, fire-resistant, low smoke and halogen-free cables shall not be lower than 0 ℃
3. Recommended bending radius: flame retardant, fire-resistant, low smoke, halogen-free control cables: unarmored cables should not be less than 6 times the outer diameter of the cable, and cables with armor or copper tape shielding structures should not be less than 12 times the outer diameter of the cable. Flame retardant, fire-resistant, low smoke and halogen-free power cables: The bending radius of single core cables shall not be less than 20 times the outer diameter of the cable, and the bending radius of multi-core cables shall not be less than 15 times the outer diameter of the cable
Cable model and name
model |
name |
Flame retardant, fire-resistant, low smoke, and halogen-free power cables | |
WDZ-YJY |
Copper core cross-linked polyethylene insulated halogen-free low smoke flame-retardant power cable (can also be made of aluminum core WDZ-YJLY) |
WDZ-YJY23 |
Copper core cross-linked polyethylene insulated steel tape armored halogen-free low smoke flame-retardant power cable (can also be made of aluminum core WDZ-YJLY23) |
WDZ-YJY33 |
Copper core cross-linked polyethylene insulated steel wire armored halogen-free low smoke flame-retardant power cable (can also be made of aluminum core WDZ-YJLY33) |
WDZN-YJY |
Copper core cross-linked polyethylene insulated halogen-free, low smoke, flame-retardant and fire-resistant power cable |
WDZN-YJY23 |
Copper core cross-linked polyethylene insulated steel tape armored halogen-free low smoke flame-retardant and fire-resistant power cable |
WDZN-YJY33 |
Copper core cross-linked polyethylene insulated steel wire armored halogen-free low smoke flame-retardant and fire-resistant power cable |
Flame retardant, fire-resistant, low smoke and halogen-free control cable | |
WDZ-KYJY |
Copper core cross-linked polyethylene insulated halogen-free low smoke flame-retardant control cable |
WDZ-KYJYP |
Copper core cross-linked polyethylene insulated copper wire shielded halogen-free low smoke flame-retardant control cable |
WDZ-KYJYP2 |
Copper core cross-linked polyethylene insulated copper tape shielded halogen-free low smoke flame-retardant control cable |
WDZ-KYJYP2-23 |
Copper core cross-linked polyethylene insulated copper tape shielded steel tape armored halogen-free low smoke flame-retardant control cable |
WDZ-KYJY33 |
Copper core cross-linked polyethylene insulated fine steel wire armored halogen-free low smoke flame-retardant control cable |
WDZN-KYJY |
Copper core cross-linked polyethylene insulated halogen-free low smoke flame-retardant and fire-resistant control cable |
WDZN-KYJYP2 |
Copper core cross-linked polyethylene insulated copper tape shielded halogen-free low smoke flame-retardant control cable |
WDZN-KYJYP2-23 |
Copper core cross-linked polyethylene insulated copper tape shielded steel tape armored halogen-free low smoke flame-retardant control cable |
Specification table for flame-retardant, fire-resistant, low smoke and halogen-free cables:
model |
rated voltage |
0.5 |
0.75 |
1.0 |
1.5 |
2.5 |
4 |
6 |
10 |
WZD-KYJY KYJYP |
600/1000V |
2-61 cores |
2-37 cores |
2-14 cores |
|||||
WZD-KYJYP2 KYJY33 |
4-61 cores |
||||||||
WDZN-KYJY |
2-61 cores |
||||||||
WDZN-KYJYP2 KYJYP2-23 |
4-61 cores |
||||||||
WDZ-YJY YJLY |
Single core: 2.5mm2~500mm2 |
||||||||
WDZ-YJY23 YJLY23 | |||||||||
WDZ-YJY33 YJLY33 | |||||||||
WDZN-YJY YJY23 | |||||||||
WDZN-YJY33 | |||||||||
The direct current resistance of the conductor complies with the provisions of GB/T3956
2. The insulation resistance constant at 90 degrees is not less than 3.67M Ω Km, The volume resistivity shall not be less than 1012 Ω Cm
3. Cable 3.5KV AC voltage test, insulation does not break down for 5 minutes
4. Flame retardant, fire-resistant, low smoke and halogen-free cable performance indicators:
Test Project |
Unit Unit |
Performance Requirements |
Test Method |
Smoke density test |
% |
60 |
GB/T17651-1998 |
Corrosion test |
μS/mm |
4.3 |
GB/T17650.2-1998(idtIEC60754) |
Content of hydrogen halide gas |
mg/g |
less than or equal to 5 |
GB/T17650.1-1998(idtIEC60754) |
Bundle test |
min |
A B C |
GB/T18380.3-2001 (Replace for GB12666.5-90) |
Product Specifications
Nominal cross-sectional area mm2 |
0.5 |
1.0 |
1.5 |
2.5 |
4 |
6 |
10 |
16 |
25 |
core count |
2-81 |
2-81 |
2-81 |
2-50 |
2-37 |
2-20 |
2-19 |
2-14 |
2-10 |
Explanation of Nouns and Terms:
Low smoke: Under the specified test conditions, the smoke released from the thermal decomposition of the sample during combustion is relatively small, which meets the specified indicator characteristics.
Halogen free: Under the specified test conditions, the content of hydrogen gas released during the combustion of the sample is extremely low or even non-existent, meeting the specified index characteristics.
Flame retardant: Under certain test conditions, the sample is burned, and after removing the fire source, the spread of the flame is only within the specified range, and the residual flame or burn can be extinguished on its own within the specified time.