E-mail
827533686@qq.com
-
Phone
13538957285
-
Address
33 Xiaoping South Road, Baiyun District, Guangzhou City, Yiying Industrial Zone
Guangzhou Xiangfeng Electromechanical Equipment Co., Ltd
827533686@qq.com
13538957285
33 Xiaoping South Road, Baiyun District, Guangzhou City, Yiying Industrial Zone
Using non-magnetic nickel chromium wire to electrically heat air as the heat source, it is clean, hygienic, and environmentally friendly. Equipped with anti dry burning and breaking function.
Clever wind tunnel design, air passes evenly from the inside/outside of the spiral electric heating wire, with nearly 100% heat exchange, low wind pressure loss, and low flow rate.
PID/SSR control, high precision, fast feedback, and long-lasting durability.
L is equipped with multiple overheating and overload protection devices to fully ensure equipment safety, and can operate continuously 365 days a year.
K-type thermocouple is installed at the air outlet for direct detection and control, ensuring a constant air temperature.
Multi fiber insulation cotton insulation, sturdy casing, safe and reliable use, can maintain high temperature operation for a long time.
The continuous use temperature can reach 350 ℃/450 ℃/500 ℃, and it is widely used.
The standard universal hot air blower adopts international brand electrical main controls (such as frequency converter, PID temperature controller, etc.), SSR, Circuit breakers, intermediate relays, magnetic switches, etc. The precision of the PID temperature controller is ± 0.5%, and it is equipped with a remote switch;
The economical universal hot air blower adopts international brand electrical main controls (such as PID thermostat, SSR, Circuit breakers, intermediate relays, magnetic switches, etc. are not equipped with frequency converters, but with motor protectors. The precision of PID temperature controller is ± 0.5%;
The practical universal hot air blower adopts domestic brand electrical main controls (such as PID thermostat, SSR, Circuit breakers, intermediate relays, magnetic switches, etc. The precision of PID temperature controller is ± 0.5% Not equipped with a frequency converter, but equipped with a motor protector.
The universal B-type hot air blower does not come with a temperature control unit device, only the fan and heating device
Model Description:
Example:
1: HWG-PP5A1-018-12 (Practical universal hot air blower, electric heating power of 5KW, single-phase 220V power supply, motor of 180W, type 1 chassis); Equipped with temperature control configuration
2: HWG-PP20A3-3-41 (practical universal hot air blower, electric heating power of 20KW, power supply of 3-phase 380V, motor of 3KW, type 4 chassis); Equipped with temperature control configuration
Practical universal hot air blower parameter table
|
model |
HWG-PP3A1-006-11 |
HWG-PP3A1-018-12 |
HWG-PP5A3-006-21 |
HWG-PP5A3-018-22 |
HWG-PP5A3-025-23 |
|
|
Power supply 50Hz |
Single phase 220V |
Single phase 220V |
Three phase 380V |
Three phase 380V |
||
|
Electric heating power |
3 kW |
3 kW |
5 kW |
5 kW |
||
|
inlet air temperature |
normal temperature |
normal temperature |
normal temperature |
normal temperature |
||
|
Air outlet temperature |
Room temperature~450 ℃ |
Room temperature~350 ℃ |
Room temperature~450 ℃ |
Room temperature~350 ℃ |
||
|
Diameter of air outlet accessories |
2″ |
2″ |
21/2″ |
21/2″ |
21/2″ |
|
|
wind
machine |
power |
60W |
180W |
60W |
180W |
250W |
|
Maximum air volume |
3.5m3/min |
6.7m3/min |
3.5m3/min |
6.7m3/min |
8.4m3/min |
|
|
Maximum wind pressure |
412Pa (full pressure) |
450Pa (full pressure) |
412Pa (full pressure) |
450Pa (full pressure) |
860Pa (full pressure) |
|
|
noise |
74dB |
72 dB |
74 dB |
72 dB |
74 dB |
|
|
configuration |
The power cord is 3m long and comes with a regular fan and temperature control |
|||||
|
weight |
20kg |
30kg |
||||
|
model |
HWG-PP7.5A3-006-24 |
HWG-PP7.5A3-018-25 |
HWG-PP7.5A3-025-26 |
HWG-PP10A3-025/055/075 -31 |
HWG-PP15A3-025/055/075-32 |
|
|
Power supply 50Hz |
Three phase 380V |
Three phase 380V |
Three phase 380V |
|||
|
Electric heating power |
7.5 kW |
7.5 kW |
10 kW |
15 kW |
||
|
inlet air temperature |
normal temperature |
normal temperature |
normal temperature |
|||
|
Air outlet temperature |
Room temperature~450 ℃ |
Room temperature~350 ℃ |
Room temperature~350 ℃ |
|||
|
Diameter of air outlet accessories |
3″ |
3″ |
3 "or 4" |
|||
|
wind
machine |
power |
60W |
180W |
250W |
250w/550W/750W |
|
|
Maximum air volume |
3.5 m3/min |
6.7 m3/min |
8.4m3/min |
8.4m3/min / 14.5m3/min / 20.5m3/min |
||
|
Maximum wind pressure |
412Pa (full pressure) |
450Pa (full pressure) |
860Pa (full pressure) |
860Pa (full pressure)/1050Pa (full pressure)/1250Pa (full pressure) |
||
|
Configuration
|
74 dB |
72 dB |
74 dB |
76 dB |
||
|
Configuration |
The power cord is 3m long and comes with a regular fan and temperature control |
|||||
|
weight |
30kg |
42kg |
||||
|
model |
HWG-PP20A3-1.5-41 |
HWG-PP25A3-1.5-42 |
HWG-PP30A3-2.2-43 |
HWG-PP35A3-2.2-44 |
HWG-PP45A3-3-45 |
HWG-PP60A3-3-46 |
||
|
Power supply 50Hz |
Three phase 380V |
Three phase 380V |
Three phase 380V |
|||||
|
Electric heating power |
2x10 kW |
2x12.5 kW |
2x15 kW |
2x17.5 kW |
2x22.5kW |
2x30 kW |
||
|
inlet air temperature |
normal temperature |
normal temperature |
normal temperature |
|||||
|
Air outlet temperature |
Room temperature~350 ℃/500 ℃ |
Room temperature~350 ℃/500 ℃ |
Room temperature~350 ℃/500 ℃ |
|||||
|
Diameter of air outlet accessories |
4 "or 5" |
5 "or 6" |
6 "or 8" |
|||||
|
wind
machine |
power |
1.5kW |
2.2kW |
3.0kW |
||||
|
Maximum air volume |
23m3/min |
24m3/min |
25m3/min |
|||||
|
Maximum wind pressure |
1.9kPa (total pressure) |
2.1kPa (total pressure) |
2.3 kPa (total pressure) |
|||||
|
configuration |
The power cord is 3m long and comes with a regular fan and temperature control |
|||||||
|
weight |
124kg |
|||||||
Practical universal hot air blower parameter table
Model: HWG-PP3A1-006-11; HWG-PP3A1-018-12; HWG-PP5A3-006-21
HWG-PP5A3-018-22; HWG-PP5A3-025-23; HWG-PP7.5A3-006-24
HWG-PP7.5A3-018-25; HWG-PP7.5A3-025-26
Function indicator diagram
dimension
|
model |
A |
B |
C |
D |
E |
F |
G |
H |
I |
J |
K |
L |
M |
P |
|
HWG-PP3A1-006-11 |
268 |
192 |
340 |
274 |
196 |
89 |
50 |
262 |
100 |
90 |
90 |
77 |
192 |
195 |
|
HWG-PP3A1-018-12 |
268 |
192 |
340 |
274 |
196 |
89 |
50 |
262 |
100 |
125 |
135 |
87 |
196 |
305 |
|
HWG-PP5A3-006-21 |
380 |
202 |
388 |
386 |
206 |
133 |
50 |
293 |
100 |
90 |
90 |
77 |
192 |
195 |
|
HWG-PP5A3-018-22 |
380 |
202 |
388 |
386 |
206 |
133 |
50 |
293 |
100 |
125 |
135 |
87 |
196 |
305 |
|
HWG-PP5A3-025-23 |
380 |
202 |
388 |
386 |
206 |
133 |
50 |
293 |
100 |
125 |
135 |
110 |
154 |
305 |
|
HWG-PP7.5A3-006-24 |
380 |
202 |
388 |
386 |
206 |
133 |
50 |
293 |
100 |
90 |
90 |
77 |
192 |
195 |
|
HWG-PP7.5A3-018-25 |
380 |
202 |
388 |
386 |
206 |
133 |
50 |
293 |
100 |
125 |
135 |
87 |
196 |
305 |
|
HWG-PP7.5A3-025-26 |
380 |
202 |
388 |
386 |
206 |
133 |
50 |
293 |
100 |
125 |
135 |
110 |
154 |
305 |
Note: 006:60W; 018:180W; 025:250W motor
Model: HWG-PP10A3-025/055/075-31; HWG-PP15A3-025/055/075-32
Function indicator diagram
dimension
|
model |
A |
B |
C |
D |
E |
F |
G |
H |
I |
J |
K |
L |
|
HWG-PP10A3-025/055/075-31 |
502 |
240 |
440 |
120 |
326 |
120 |
80 |
340 |
102 |
121 |
108 |
110 |
|
130 |
150 |
131 |
142 |
|||||||||
|
130 |
150 |
131 |
142 |
|||||||||
|
HWG-PP15A3-025/055/075-32 |
502 |
240 |
440 |
120 |
267 |
120 |
80 |
340 |
102 |
121 |
108 |
110 |
|
130 |
150 |
131 |
142 |
|||||||||
|
130 |
150 |
131 |
142 |
Note: 006:60W; 018:180W; 025:250W motor
Model: HWG-PP10A3-025/055/075-31; HWG-PP15A3-025/055/075-32
Function indicator diagram
dimension
|
Model number |
A |
C |
D |
E |
F |
G |
H |
I |
J |
K |
L |
M |
N |
|
HWG-PP20A3-1.5-41 |
590 |
600 |
360 |
360 |
560 |
100 |
685 |
157 |
157 |
182 |
395 |
130 |
1200 |
|
HWG-PP25A3-1.5-42 |
|||||||||||||
|
HWG-PP30A3-2.2-43 |
590 |
600 |
360 |
360 |
560 |
100 |
685 |
157 |
157 |
182 |
395 |
130 |
1200 |
|
HWG-PP35A3-2.2-44 |
|||||||||||||
|
HWG-PP45A3-3-45 |
590 |
600 |
360 |
360 |
560 |
100 |
685 |
180 |
180 |
206 |
365 |
130 |
1200 |
|
HWG-PP60A3-3-46 |
Note: 1.5KW/2.2KW/3KW motors
Practical universal hot air blower outlet size diagram (optional accessories)
|
model |
A |
B |
C |
|
HWG-PP3A1-006-11 |
φ57 /φ76 |
89 |
φ89 |
|
HWG-PP3A1-018-12 |
|||
|
HWG-PP5A3-006-21 |
φ76 /φ89 /φ108 |
127 |
φ133
|
|
HWG-PP5A3-018-22 |
|||
|
HWG-PP5A3-025-23 |
|||
|
HWG-PP7.5A3-006-24 |
|||
|
HWG-PP7.5A3-018-25 |
|||
|
HWG-PP7.5A3-025-26 |
|||
|
HWG-PP10A3-025/055/075-31 |
|||
|
HWG-PP15A3-025/055/075-32 |
|||
|
HWG-PP20A3-1.5-41 |
φ89 /φ108 /φ133 /φ159 |
152
|
φ219
|
|
HWG-PP25A3-1.5-42 |
|||
|
HWG-PP30A3-2.2-43 |
|||
|
HWG-PP35A3-2.2-44 |
|||
|
HWG-PP45A3-3-45 |
|||
|
HWG-PP60A3-3-46 |