Universal high-pressure hot air blower

Product Details

2080 nickel chromium wire electrically heats air as a hot air source, which is clean, hygienic, and environmentally friendly. Equipped with anti dry burning and breaking function.

Clever wind tunnel design, air passes evenly from the inside/outside of the spiral electric heating wire, with nearly 100% heat exchange, low wind pressure loss, and low flow rate.

PID/SSR control, high precision, fast feedback, and long-lasting durability.

L is equipped with multiple overheating and overload protection devices to fully ensure equipment safety, and can operate continuously 365 days a year.

K-type thermocouple is installed at the air outlet for direct detection and control, ensuring a constant air temperature.

Multi fiber insulation cotton insulation, sturdy casing, safe and reliable use, can maintain high temperature operation for a long time.

The continuous use temperature can reach 350 ℃, and it is widely used.

The standard circulating hot air fan adopts a patented design of the heat dissipation device, with a continuous inlet air temperature of up to 150 ℃. The air volume is adjusted by a frequency converter, which is more energy-saving, highly controllable, and has excellent characteristics such as less heat loss.

There are also remote switches (6m) and fan covers available for selection.

The standard universal high-pressure hot air blower adopts international brand electrical main controls (such as frequency converter, PID temperature controller, etc.), SSR, Circuit breakers, intermediate relays, magnetic switches, etc. The precision of the PID temperature controller is ± 0.5%, and it is equipped with a remote switch;

The economical and universal high-pressure hot air blower adopts international brand electrical main controls (such as PID thermostat, SSR, Circuit breakers, intermediate relays, magnetic switches, etc. are not equipped with frequency converters, but with motor protectors. The precision of PID temperature controller is ± 0.5%;

The practical universal high-pressure hot air blower adopts domestic brand electrical main controls (such as PID thermostat, SSR, Circuit breakers, intermediate relays, magnetic switches, etc. The precision of PID temperature controller is ± 0.5% Not equipped with a frequency converter, but equipped with a motor protector.

Characteristics and Comparison:

The comparison between Baofeng heater and general heating tube is shown in the following table:


Serial number

Baofeng Heater

General heating tube

1

Hot air is directly emitted through the heating wire, with a heat exchange efficiency of almost 100%

Hot air is emitted from the heating wire through the filling material to the sheath, greatly reducing efficiency

2

Due to the fact that the hot air is directly obtained from the heating wire (with faster heating and cooling times)

Due to the fact that hot air is indirectly heated (with a longer heating time and reduced service life)

3

No filler material, it will not affect the quality due to aging of the filler material

The filling material inside the heating tube is prone to aging, which affects the heating effect

4

It can visually and directly inspect the heating wire, and discover problems in a timely manner

If there is a problem with the hidden heating wire, it is difficult to detect and can be dangerous

5

Spiral/circular winding of heating wire, with a total length several times longer than straight winding, lower surface power (as low as 3.8W/cm2), and longer service life

The surface power density (W/cm2) of the internal heating wire is relatively high, greatly reducing its service life

6

The built-in overheating protection device can protect the heating wire from burning out due to lack of air flow

This function is not available


Model Description:

Example:

1: HWG-HSP3A3-040-21 (standard universal high-voltage hot air blower, electric heating power of 3KW, power supply of 3-phase 380V, motor of 400W, type 2 chassis); Equipped with temperature control configuration

2: HWG-HPP15A3-7.5-34 (practical universal high-voltage hot air blower, electric heating power of 15KW, power supply of 3-phase 380V, motor of 7.5KW, type 3 chassis); Equipped with temperature control configuration

HWG-HP standard/economical/practical universal high-pressure hot air blower

Standard/economical/practical universal high-pressure hot air blower parameter table:


model

HWG-HS/E/PP3A1-040-21

HWG-HS/E/PP5A3-

075-22

HWG-HS/E/PP7.5A3-1.5-23

HWG-HS/E/PP10A3-1.5-31

Power supply 50Hz

1φ220V

3φ380V

3φ380V

3φ380V

Electric heating power

3kW

5kW

7.5kW

10kW

Adjustment range of outlet air temperature

Room temperature~350oC

Room temperature~350oC

Room temperature~350oC

Room temperature~350oC

Inlet temperature

Room temperature~150oC

Room temperature~150oC

Room temperature~150oC

Room temperature~150oC

Diameter of air outlet

2 "or 21/2"

2 "or 21/2"

21/2 "or 3"

21/2 "or 3"

wind

machine

power

400W

750W

1.5kW

1.5kW

Maximum air volume

1.3m3/min

2.4m3/min

3.5m3/min

3.5m3/min

Maximum wind pressure

13kPa

16kPa

19kPa

19kPa

weight

42kg

53kg

62kg

81kg


model

HWG-HS/E/PP15A3-2.2-32

HWG-HS/E/PP15A3-5.5-33

HWG-HS/E/PP15A-

7.5-34

HWG-HS/E/PP20A-

5.5-41

Power supply 50Hz

3φ380V

3φ380V

3φ380V

3φ380V

Electric heating power

15kW

15kW

15kW

20kW

Adjustment range of outlet air temperature

Room temperature~350oC

Room temperature~350oC

Room temperature~350oC

Room temperature~350oC

Inlet temperature

Room temperature~150oC

Room temperature~150oC

Room temperature~150oC

Room temperature~150oC

Diameter of air outlet

3 "or 4"

3 "or 4"

3 "or 4"

4 "or 5"

wind

machine

power

2.2kW

5.5kW

7.5kW

5.5kW

Maximum air volume

3.7m3/min

8.8m3/min

8.8m3/min

8.8m3/min

Maximum wind pressure

20kPa

32kPa

38kPa

32kPa

weight

91kg

133kg/170kg/175kg

135kg/172kg/177kg

168kg/205kg/210kg


model

HWG-HS/E/PP20A-

7.5-42

HWG-HS/E/PP30A-

5.5-43

HWG-HS/E/PP30A-

7.5-44

Power supply 50Hz

3φ380V

3φ380V

3φ380V

Electric heating power

20kW

30kW

30kW

Adjustment range of outlet air temperature

Room temperature~350oC

Room temperature~350oC

Room temperature~350oC

Inlet temperature

Room temperature~150oC

Room temperature~150oC

Room temperature~150oC

Diameter of air outlet

4 "or 5"

4 "or 5"

4 "or 5"

wind

machine

power

7.5kW

5.5kW

7.5kW

Maximum air volume

8.8m3/min

8.8m3/min

8.8m3/min

Maximum wind pressure

38kPa

32kPa

38kPa

weight

170kg/207kg/212kg

185kg/222kg/227kg

187kg/224kg/229kg


HWG-HP standard/economical/practical universal high-pressure hot air blower size diagram


model

A

B

C

D

E

F

G

H

I

J

K

Pairing Lan method air outlet joint

HWG-HS/E/PP3A1-040-21

380

50

133

400

202

400

400

300

1100

450

30

2 "or 21/2"

HWG-HS/E/PP5A3-075-22

360

HWG-HS/E/PP7.5A3-1.5-23

390

HWG-HS/E/PP10A3-1.5-31

502

80

133

442

250

450

450

390

1400

600

30

21/2 "or 3"

HWG-HS/E/PP15A3-2.2-32

425

HWG-HS/E/PP15A3-5.5-33

520

HWG-HS/E/PP15A-7.5-34

520

HWG-HS/E/PP20A-5.5-41

685

100

219

590

250

560

560

520

1600

600

30

3 "or 4"

HWG-HS/E/PR20A-7.5-42

HWG-HS/E/PP30A-5.5-43

HWG-HS/E/PP30A-7.5-44


soundproofCover is an optional accessory