Welcome Customer !

Membership

Help

Shanghai Fanyang Electromechanical Co., Ltd
Custom manufacturer

Main Products:

foodequippro>Products

Shanghai Fanyang Electromechanical Co., Ltd

  • E-mail

    fanyangjidian@163.com

  • Phone

  • Address

    Room 202, No. 4, Lane 558, Tianbao Road, Hongkou District, Shanghai

Contact Now

TF10 flange type TF15 thread type TF20 welded thermal resistance thermocouple bimetallic thermometer sleeve

NegotiableUpdate on 10/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

1、 Product Introduction: TF Series Thermocouples, Thermistors, and Bimetallic Thermometers Installation Sleeves are important components in all temperature measurement applications. They can isolate the measurement process from the measured medium, not only protecting the surrounding environment and personnel, but also separating corrosive, high-temperature, high-pressure, and high flow media from the sensor. Users can also replace the sensor during operation

Product Details

1、 Product IntroductionProduct Introduction

TFThe installation sleeve of series thermocouples, thermistors, and bimetallic thermometers is an important component in all temperature measurement applications. It can isolate the measurement process from the measured medium, not only protecting the surrounding environment and personnel, but also separating corrosive, high-temperature, high-pressure, and high flow media from the sensor. Users can also replace the sensor during work.

TFseries thermocouple, thermistor, and bimetallic thermometer installation sleeveare important components in all temperature measurement applications. They canisolate the measurement process from the measured medium, not only protectingthe surrounding environment and workers, but also isolating corrosive, hightemperature, high pressure, and high flow media from the sensor. Users can alsoreplace the sensor during work.


TFThere are various styles and materials of installation sleeves in the series, which can meet various application requirements. The interface type and basic manufacturing process room are important design option elements. Normally, casing is mainly divided into welded, threaded, and flanged types.

TF series installation sleeves come in variousstyles and materials, which can meet various application requirements. Interface types and important design option elements for basic manufacturingprocess rooms. Usually, casings are mainly divided into welded, threaded, andflanged types.


2、 Product Features Product features

TFThe installation sleeves for series thermocouples, thermistors, and bimetallic thermometers are all referencedIECInternational standard design, blind hole processing, high pressure resistance, manufactured and installed simultaneously with the equipment, different pressure levels can meet different needs.

TFseries thermocouples, thermal resistors, and bimetallic thermometerinstallation sleeves are all designed according to IEC international standards,with blind hole processing, high pressure resistance, and manufactured andinstalled simultaneously with the equipment. Different pressure levels can meetdifferent needs.


TFThere are multiple options for connecting the installation sleeves of series thermocouples, thermistors, and bimetallic thermometers. There are also various materials to choose from. Can meet the needs of almost all places!

TF series thermocouples, thermistors, and bimetallic thermometers can be installedwith multiple sleeve connection methods. There are also multiple materialsavailable for selection. Can meet almost all usage needs!


3、 Technical parameters Technical parameter

Nominal pressure: generally refers to the static external pressure that the protective tube can withstand at room temperature without breaking. The allowable working pressure is not only related to the material, diameter, and wall thickness of the protective tube, but also to its structural form, installation method, and the flow rate and type of the measured medium.

Nominalpressure: generally refers to the static external pressure that the protectivetube can withstand without rupture at room temperature. The allowable workingpressure is not only related to the material, diameter, and wall thickness ofthe protective tube, but also to its structural form, installation method, andthe flow rate and type of the measured medium.


Water pressure test: When there are requirements for the pressure resistance and leakage inspection of the protective tube, the protective tube must be tested. The test pressure is the pressure resistance level of the protective tube15Twice.XRadiographic testing: When there are requirements for checking the wall thickness, eccentricity, and other items of the protective tube, the inspection must be carried out according to the user's requirements.

Waterpressure test: When there are requirements for the pressure resistance andleakage inspection of the protective tube, the protective tube must be tested. The test pressure is 15 times the pressure rating of the protective tube. X-rayinspection test: When there are requirements for inspecting the wall thickness,eccentricity, and other items of the protective tube, it must be inspectedaccording to the user's requirements.

TF热套管技术参数.png


4、 Selection Chart Selection chart

TF热套管选型图谱.png


5、 External dimensions External dimensions

TF热套管外形尺寸.png


6、 Product classificationProduct classification

TF热套管产品分类.png

The above parameters are for reference only and are subject to change without prior notice!

Above parameters arefor reference only and are subject to change without prior notice!