Welcome Customer !

Membership

Help

Guangzhou Xiangfeng Electromechanical Equipment Co., Ltd
Custom manufacturer

Main Products:

foodequippro>Products

Guangzhou Xiangfeng Electromechanical Equipment Co., Ltd

  • E-mail

    827533686@qq.com

  • Phone

    13538957285

  • Address

    33 Xiaoping South Road, Baiyun District, Guangzhou City, Yiying Industrial Zone

Contact Now

Ship painting hot air blower

NegotiableUpdate on 10/20
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Ship painting hot air blower

Product Details

Using non-magnetic nickel chromium wire to electrically heat air as the heat source, it is clean, hygienic, and environmentally friendly. Equipped with anti dry burning and breaking function.

Clever wind tunnel design, air passes evenly from the inside/outside of the spiral electric heating wire, with nearly 100% heat exchange, low wind pressure loss, and low flow rate.

PID/SSR control, high precision, fast feedback, and long-lasting durability.

L is equipped with multiple overheating and overload protection devices to fully ensure equipment safety, and can operate continuously 365 days a year.

K-type thermocouple is installed at the air outlet for direct detection and control, ensuring a constant air temperature.

Multi fiber insulation cotton insulation, sturdy casing, safe and reliable use, can maintain high temperature operation for a long time.

The continuous use temperature can reach 350 ℃/550 ℃/800 ℃, and it is widely used.

The standard universal hot air blower adopts international brand electrical main controls (such as frequency converter, PID temperature controller, etc.), SSR, Circuit breakers, intermediate relays, magnetic switches, etc. The precision of the PID temperature controller is ± 0.5%, and it is equipped with a remote switch;

The economical universal hot air blower adopts international brand electrical main controls (such as PID thermostat, SSR, Circuit breakers, intermediate relays, magnetic switches, etc. are not equipped with frequency converters, but with motor protectors. The precision of PID temperature controller is ± 0.5%;

The practical universal hot air blower adopts domestic brand electrical main controls (such as PID thermostat, SSR, Circuit breakers, intermediate relays, magnetic switches, etc. The precision of PID temperature controller is ± 0.5% Not equipped with a frequency converter, but equipped with a motor protector.

The universal B-type hot air blower does not come with a temperature control unit device, only the fan and heating device

Model Description:

Example:

1: HWG-PP5A1-018-12 (Universal hot air blower, electric heating power of 5KW, single-phase 220V power supply, motor of 180W, Type 1 chassis); Equipped with temperature control configuration

2: HWG-PP20A3-3-41 (Universal hot air blower, electric heating power of 20KW, power supply of 3-phase 380V, motor of 3KW, type 4 chassis); Equipped with temperature control configuration

General type hot air blower parameter table


model

HWG-PP3A1-006-11

HWG-PP3A1-018-12

HWG-PP5A3-006-21

HWG-PP5A3-018-22

HWG-PP5A3-025-23

Power supply 50Hz

Single-phase 220V

Single-phase 220V

Three phase 380V

Three phase 380V

Electric heating power

3 kW

3 kW

5 kW

5 kW

inlet air temperature

room temperature

room temperature

room temperature

room temperature

outlet air temperature

Room temperature~450 ℃

Room temperature~350 ℃

Room temperature~450 ℃

Room temperature~350 ℃

Diameter of air outlet accessories

2″

2″

21/2″

21/2″

21/2″

wind

machine

power

60W

180W

60W

180W

250W

Maximum Airflow

3.5m3/min

6.7m3/min

3.5m3/min

6.7m3/min

8.4m3/min

Maximum wind pressure

412Pa (full pressure)

450Pa (full pressure)

412Pa (full pressure)

450Pa (full pressure)

860Pa (full pressure)

noise

74dB

72 dB

74 dB

72 dB

74 dB

configuration

The power cord is 3m long and comes with a regular fan and temperature control

weight

20kg

30kg


model

HWG-PP7.5A3-006-24

HWG-PP7.5A3-018-25

HWG-PP7.5A3-025-26

HWG-PP10A3-025/055/075

-31

HWG-PP15A3-025/055/075-32

Power supply 50Hz

Three phase 380V

Three phase 380V

Three phase 380V

Electric heating power

7.5 kW

7.5 kW

10 kW

15 kW

inlet air temperature

room temperature

room temperature

room temperature

outlet air temperature

Room temperature~450 ℃

Room temperature~350 ℃

Room temperature~350 ℃

Diameter of air outlet accessories

3″

3″

3 "or 4"

wind

machine

power

60W

180W

250W

250w/550W/750W

Maximum Airflow

3.5 m3/min

6.7 m3/min

8.4m3/min

8.4m3/min / 14.5m3/min / 20.5m3/min

Maximum wind pressure

412Pa (full pressure)

450Pa (full pressure)

860Pa (full pressure)

860Pa (full pressure)/1050Pa (full pressure)/1250Pa (full pressure)

Configuration

74 dB

72 dB

74 dB

76 dB

Configuration

The power cord is 3m long and comes with a regular fan and temperature control

weight

30kg

42kg


model

HWG-PP20A3-1.5-41

HWG-PP25A3-1.5-42

HWG-PP30A3-2.2-43

HWG-PP35A3-2.2-44

HWG-PP45A3-3-45

HWG-PP60A3-3-46

Power supply 50Hz

Three phase 380V

Three phase 380V

Three phase 380V

Electric heating power

2x10 kW

2x12.5 kW

2x15 kW

2x17.5 kW

2x22.5kW

2x30 kW

inlet air temperature

room temperature

room temperature

room temperature

outlet air temperature

Room temperature~350 ℃/500 ℃

Room temperature~350 ℃/500 ℃

Room temperature~350 ℃/500 ℃

Diameter of air outlet accessories

4 "or 5"

5 "or 6"

6 "or 8"

wind

machine

power

1.5kW

2.2kW

3.0kW

Maximum Airflow

23m3/min

24m3/min

25m3/min

Maximum wind pressure

1.9kPa (total pressure)

2.1kPa (total pressure)

2.3 kPa (total pressure)

configuration

The power cord is 3m long and comes with a regular fan and temperature control

weight

124kg


General type hot air blower parameter table

型号: HWG-PP3A1-006-11; HWG-PP3A1-018-12; HWG-PP5A3-006-21

HWG-PP5A3-018-22; HWG-PP5A3-025-23; HWG-PP7.5A3-006-24

HWG-PP7.5A3-018-25; HWG-PP7.5A3-025-26

Function indicator diagram

Size chart


model

A

B

C

D

E

F

G

H

I

J

K

L

M

P

HWG-PP3A1-006-11

268

192

340

274

196

89

50

262

100

90

90

77

192

195

HWG-PP3A1-018-12

268

192

340

274

196

89

50

262

100

125

135

87

196

305

HWG-PP5A3-006-21

380

202

388

386

206

133

50

293

100

90

90

77

192

195

HWG-PP5A3-018-22

380

202

388

386

206

133

50

293

100

125

135

87

196

305

HWG-PP5A3-025-23

380

202

388

386

206

133

50

293

100

125

135

110

154

305

HWG-PP7.5A3-006-24

380

202

388

386

206

133

50

293

100

90

90

77

192

195

HWG-PP7.5A3-018-25

380

202

388

386

206

133

50

293

100

125

135

87

196

305

HWG-PP7.5A3-025-26

380

202

388

386

206

133

50

293

100

125

135

110

154

305


Note: 006:60W; 018:180W; 025:250W motor

型号: HWG-PP10A3-025/055/075-31; HWG-PP15A3-025/055/075-32Function indicator diagram

Size chart


model

A

B

C

D

E

F

G

H

I

J

K

L

HWG-PP10A3-025/055/075-31

502

240

440

120

326

120

80

340

102

121

108

110

130

150

131

142

130

150

131

142

HWG-PP15A3-025/055/075-32

502

240

440

120

267

120

80

340

102

121

108

110

130

150

131

142

130

150

131

142


Note: 250W/550W/750W motors

型号: HWG-PP20A3-1.5-41; HWG-PP25A3-1.5-42; HWG-PP30A3-2.2-43

HWG-PP35A3-2.2-44; HWG-PP45A3-3-45; HWG-PP60A3-3-46

Function indicator diagram

Size chart


Model number

A

C

D

E

F

G

H

I

J

K

L

M

N

HWG-PP20A3-1.5-41

590

600

360

360

560

100

685

157

157

182

395

130

1200

HWG-PP25A3-1.5-42

HWG-PP30A3-2.2-43

590

600

360

360

560

100

685

157

157

182

395

130

1200

HWG-PP35A3-2.2-44

HWG-PP45A3-3-45

590

600

360

360

560

100

685

180

180

206

365

130

1200

HWG-PP60A3-3-46


Note: 1.5KW/2.2KW/3KW motors

Universal hot air blower vent size diagram (optional accessories)


model

A

B

C

HWG-PP3A1-006-11

φ57 /φ76

89

φ89

HWG-PP3A1-018-12

HWG-PP5A3-006-21

φ76 /φ89 /φ108

127

φ133

HWG-PP5A3-018-22

HWG-PP5A3-025-23

HWG-PP7.5A3-006-24

HWG-PP7.5A3-018-25

HWG-PP7.5A3-025-26

HWG-PP10A3-025/055/075-31

HWG-PP15A3-025/055/075-32

HWG-PP20A3-1.5-41

φ89 /φ108 /φ133 /φ159

152

φ219

HWG-PP25A3-1.5-42

HWG-PP30A3-2.2-43

HWG-PP35A3-2.2-44

HWG-PP45A3-3-45

HWG-PP60A3-3-46