The HD-DL1 SF6 gas concentration online monitoring and alarm system (hereinafter referred to as the system) is a high-tech new product developed by our company specifically for the personal protection needs of indoor workers such as SF6 switch rooms and GIS rooms. This system uses original imported sensors Scope of application: Online monitoring series, intelligent distribution series, line monitoring series

Product Details

1、 Product Introduction
SF6 leakage alarm
monitorsystemMainly used in GIS rooms with different voltage levels such as 110KV, 220KV, 500KV in substations, SF6 combination electrical equipment rooms, and 10KV, 35KV high-voltage switch rooms to monitor SF6 gas leakage in the environment and oxygen content in the air in real time. When SF6 gas leakage occurs, due to its density being more than five times that of air, it accumulates in the lower space and causes local oxygen deficiency, leading to major accidents. This system uses high-sensitivity imported SF6-O2 sensors and temperature and humidity sensors. When there are small changes in the concentration of SF6 and O2 indoors, the sensors can immediately respond to these changes, even if the SF6 concentration is at 50ppm (v/v), it can effectively monitor. The concentration change monitored by the sensor is detected in real-time online through the SF6&O2 integrated monitoring unit. It is converted into a 485 communication digital signal through the A/D module, 485 communication module, and microcontroller control. The signal is sent to the SF6 monitoring host through the on-site RS-485 bus for data processing and storage, as well as determining whether to alarm, start the fan, and perform remote communication functions.

According to Chapter 8 of the "DL408-1991 Electricity Safety Work Regulations (Electrical Part of Power Plants and Substations)", Chapter 4 of the "DLT 639-1997 Safety Protection Rules for SF6 Electrical Equipment Operation, Testing and Maintenance Personnel", and the "JBT 10893-2008 SF6 Environmental Monitoring System for High Voltage Combination Electrical Equipment Distribution Room".

2、 Main functions
◇ SF6 gas content detection function in the environment.
◇ Oxygen content detection function in the air.
◇ Temperature and humidity detection display function in the environment.
◇ Oxygen deficiency alarm function.
◇ SF6 gas content over limit alarm function.
◇ Automatic exhaust function when oxygen deficiency or SF6 content exceeds the standard.
◇ Timed exhaust function.
◇ Manual forced exhaust function.
Real time display of various parameter functions.
◇ Historical data query function.
◇ Dispatch center monitoring, providing remote communication hard contacts to communicate with remote control devices, realizing remote alarm of dispatch center, and uploading data to the server in the central control room.