Welcome Customer !

Membership

Help

Shanghai Guanwei Instrument Co., Ltd
Custom manufacturer

Main Products:

foodequippro>Products

Shanghai Guanwei Instrument Co., Ltd

  • E-mail

    shgw17@163.com

  • Phone

    18862269909,13681772035

  • Address

    Room 1503, No. 289 Qianjin East Road, Kunshan Economic Development Zone, Jiangsu Province

Contact Now

Rapid moisture analyzer

NegotiableUpdate on 04/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

AND rapid moisture analyzer MF-50 halogen moisture analyzer weighing range 0.002g-51g; The moisture content is 0.01% -0.1%, and the heating temperature is 50-200 degrees.

Product Details

ANDRapid moisture analyzerMF-50ofcharacteristic:

Having innovationSRARapid and uniform technologyHalogen lamp heatingimplement
Adopting straight tube halogen lamps and * designSRA(Secondary radiation auxiliary device) Radiators are used to shorten measurement time and form a fast and uniform heater.
useSHSThe fast and sensitive weighing sensor enables very few samples to be accurately measured for moisture content under high-precision weighing.
Using sodium tartrate dihydrate as the standard for checking the accuracy of moisture content measurement
Sodium tartrate dihydrate is a substance with a stable water content15.66%+0.3/-0.1Chemical substances,Therefore, Zui can be trusted to perform accuracy checks and provide measuring instruments as reference values.

standardWinCT-MoistureSoftware (only)MS/MX)Realize real-time graphic display
WinCT-Moisture
The software is a moisture content analysis software designed specifically for graphic display, which can display the graph of moisture content changes during measurement, and can use this graph to analyze the moisture content,Set up measurement programs for different samples through computer-aided analysis.
Measurement program,Measurement result storage function
Zui Multi Energy Storage20Group measurement program, calling different measurement programs according to different samples at any time for moisture content determination,Therefore, it can achieve fast measurement and avoid setting operation errors(MFZui Multi Storage10group, MLZui Multi Storage5Group). Measurement results can be stored100Group(MFdo50group, MLdo30Group) and output through computer or printer.*Avoid human error.
conform toGLP/GMP/GCPandISOStandard, with date/Time,IDCalibration data and detection record output
Capable of recording and outputting calibration and measurement data to meet quality management and certification requirements.
standardRS-232interface
givePCBidirectional communication or connection to a printer.
Clear and easy to observe large screen fluorescent display
The measurement program, set value, moisture content change rate, measurement status, data number, and other important information are displayed clearly at a glance.

Guarantee of low maintenance costs
Users do not need to stop using halogen lamps when replacing them, and the protected chamber is easy to clean (the lifespan of halogen lamps is about5000Hour)
Five measurement programs
Standard mode: Measurement is automatically completed by setting high, medium, and low measurement accuracy.
Automatic mode: When the moisture content change rate is less than a set ratio, the measurement will automatically end.
quick mode:In order to achieve rapid measurement, before startup3Minute adoption200Heat up and then complete the measurement according to the automatic settings.
Timer mode: Measurement is completed by setting the duration.
Manual mode: operate the measurement process by pressing the start and stop keys.
Four drying procedures
Standard drying:Heat up directly to the set temperature after startup.
Asymptotic drying:Gradually raise the temperature to the set temperature after a preset time.
Step wise drying:Adopt different temperatures in stages according to time.
Rapid drying:use200rapid heating3After minutes, continue heating according to the set drying temperature.
Any combination of measurement and drying programs can fully meet the measurement requirements of different samples.

Standard accessories
Sample tray(MS/MX/MFhave20One,MLhave10A)
Disk handle(MS/MX/MFhave2One,MLhave1A)
Tweezers, sample spoon, and inspection sample (sodium tartrate dihydrate)30g)(Only)MS/MX/MF
●CD-ROM
MS/MXdoWinCT-MoistureMFdoWinCT
●MS/MX
join in marriageRS-232Line,
Display film
Dust film (only)MS/MX/MF)
User Manual

Quick access card
power line
Two fuses

ANDRapid moisture analyzerMF-50Parameters of:

model

MS-70

MX-50

MF-50

ML-50

heat source

400Whalogen lamp

400Whalogen lamp

400Whalogen lamp

400Whalogen lamp

Weighing range

71g

51g

51g

51g

Reading accuracy

0.0001g

0.001g

0.002g

0.005g

water content
measuring accuracy

0.001/0.01/0.1%

0.01/0.1%

0.05/0.1/1%

0.1/1%

Temperature preset range

30-200linear measure

50-200linear measure

50-200linear measure

50-200linear measure

moisture content

Display mode

relative moisture content,moisture content,ratio of wetting-drying-time,Wet dry ratio

relative moisture content,moisture content,ratio of wetting-drying-time,Wet dry ratio

relative moisture content,moisture content,ratio of wetting-drying-time,Wet dry ratio

relative moisture content,moisture content,ratio of wetting-drying-time,Wet dry ratio

Measurement method

standard,automatic,at regular time,hand movement

standard,automatic, at regular time,hand movement

standard,automatic, at regular time,hand movement

standard,automatic, at regular time,hand movement

Weighing disk size(mm)

diameter 85

diameter 85

diameter 85

diameter 85

External dimensions W×D×H(mm)

215 x 320 x 173

215 x320 x 173

215 x 320 x 173

215x 320 x 173

weightmake an appointmentKg)

6.0

6.0

6.0

6.0


Related products:MF-50 Japan andMoisture meter MF-50

Moisture meter AND MX-50 Japanese Kate FD-610moisture meter