NegotiableUpdate on 01/08
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

We are a professional manufacturer of Pneumatic Thin Film Low Temperature Control Valve/ZMAP-16D. Our independently developed and produced Pneumatic Control Valve has reliable quality, reasonable price, and complete after-sales service. Pneumatic thin film low-temperature regulating valve/ZMAP-16D is suitable for various light and heavy industries and building pipelines. Nen En quality, shared globally! Regulating valves are widely used in various fields such as chemical, petrochemical, petroleum, papermaking, mining, electricity, liquefied gas, food, pharmaceuticals, water supply and drainage, municipal, mechanical equipment supporting, electronic industry, urban construction, etc.

Product Details

Professional manufacturer of Pneumatic Thin Film Low Temperature Regulating Valve/ZMAP-16D, independently developed and produced by our factory【pneumatic control valve】Reliable quality, reasonable price, and comprehensive after-sales service. 『Pneumatic thin film low-temperature regulating valve/ZMAP-16DSuitable for various light and heavy industries as well as building pipelines. Nen En quality, shared globally! 【control valve】Widely used in fields such as chemical, petrochemical, petroleum, papermaking, mining, electricity, liquefied gas, food, pharmaceuticals, water supply and drainage, municipal, mechanical equipment supporting, electronics industry, urban construction, etc.

Product Name Pneumatic thin film low-temperature regulating valve/ZMAP-16D
Product Model ZMAP-16D
Nominal Diameter DN20-200
pressure range 1.0-6.4MPa
Valve body material Cast iron 丨 ductile iron 丨 cast steel 丨 stainless steel


We are a professional manufacturer of Pneumatic Thin Film Low Temperature Regulating Valve/ZMAP-16D. Our independently developed and produced regulating valve has reliable quality, reasonable price, and complete after-sales service. Pneumatic thin film low-temperature regulating valve/ZMAP-16D is suitable for various light and heavy industries and building pipelines. Nen En quality, shared globally! Regulating valves are widely used in various fields such as chemical, petrochemical, petroleum, papermaking, mining, electricity, liquefied gas, food, pharmaceuticals, water supply and drainage, municipal, mechanical equipment supporting, electronic industry, urban construction, etc.

control valve】Valve body type selection: There are many types of valve bodies for regulating valves, and commonly used valve body types include ① straight through single seat ② straight through double seat ③ angular ④ diaphragm ⑤ small flow ⑥ three-way ⑦ eccentric rotation ⑧ butterfly ⑨ sleeve type ⑩ spherical, etc. When selecting a regulating valve, the following considerations can be made: (1) Valve core shape and structure: mainly based on the selected flow characteristics and unbalanced forces. (2) Wear resistance: When the fluid medium is a suspension containing high concentrations of abrasive particles, the internal material of the valve should be hard. (3) Corrosion resistance: Due to the corrosive nature of the medium, it is advisable to choose valves with simple structures. (4) Temperature and pressure of the medium: When the temperature and pressure of the medium are high and vary greatly, valves with valve cores and seats that are less affected by temperature and pressure changes should be selected. When the temperature is ≥ 250 ℃, a radiator should be added. (5) Prevent flash evaporation and cavitation: Flash evaporation and cavitation only occur in liquid media. In the actual production process, flash evaporation and cavitation can cause vibration and noise, shortening the service life of valves. Therefore, when selecting valves, precautions should be taken to prevent flash evaporation and cavitation.


Overview of Pneumatic Thin Film Low Temperature Regulating Valve:

Pneumatic thin film low-temperature regulating valve is a modified product of single and double seat regulating valves. It differs from the ambient temperature regulating valve in that it uses a long necked upper valve cover to keep the packing working at room temperature. Suitable for regulating media (such as liquid oxygen, liquid nitrogen, etc.) at low temperatures ranging from -60 to -250 ℃. To ensure adjustment accuracy, a valve positioner must be used.

【1】 Structural principle:

The pneumatic low-temperature regulating valve consists of two parts: a pneumatic diaphragm actuator and low-temperature resistant single and double seat valves. The signal pressure from the regulator is input into the air chamber of the pneumatic diaphragm actuator, generating thrust. The valve core is driven by the connecting rod, and the change in the position of the valve core changes the flow cross-sectional area of the valve, achieving the regulation of the medium flow rate.

【2】 Main technical indicators:


Nominal Diameter
DN

single seat

20

25

32

40

50

65

80

100

125

150

200

two-seater


25

32

40

50

65

80

100

125

150

200

rated flow
Coefficient Kv

single seat

0.08

0.12

0.20

0.32

0.50

0.80

1.2

2.0

3.2

5.0

8

12

20

32

50

80

120

200

280

450

two-seater


10

6

25

40

63

100

160

250

400

630

flow characteristics

straight line

Straight line; Equal percentage

Equipped with actuator model



ZMA -2

ZMA -3

ZMA -4

ZMA-5

itinerary

10

10

16

25

40

60

mode of action

Airtight (B), Airtight (K)

Spring pressure range KPa

Standard signal: 20-100; Other signals; 40~200; 20~60; 60~100
























【3】 Precautions for installation and use of pneumatic thin film low-temperature regulating valve:

(1) It should be installed vertically on a horizontal pipeline. In special cases where horizontal or inclined installation is required, support should generally be added. The circular board installed on the insulation box wall should be parallel to the insulation box wall.
(2) It should be installed near the ground or floor for maintenance and repair purposes. For those equipped with valve positioners or handwheel mechanisms, it is even more important to ensure easy observation, adjustment, and operation.
(3) Generally, a bypass pipeline is set up to switch to manual operation in case of automatic control system failure or maintenance of regulating valves, so as not to stop production.
(4) When equipped with a handwheel mechanism, manual operation of the bypass pipeline can also be omitted, and it can also be used to limit the opening of the valve. When stopped, the handwheel mechanism must be restored to its original neutral position to facilitate the normal operation of the self-control system.
(5) During installation, the flow direction of the medium should be consistent with the direction indicated on the valve body.
(6) Before installing the regulating valve, the pipeline should be cleaned of dirt and welding slag. After installation, fully open the regulating valve, clean the pipelines, valves, etc., and test the sealing of each connection.

【4】 Main connection dimensions of pneumatic thin film low-temperature regulating valve:

Nominal diameter DN (mm)


20

25

32

40

50

65

80

100

125

150

200

A

230

280

280

325

410

495


135

235

235

255

280

310

345

370

430

470

550

660

1

160

260

260

285

305

340

375

405

460

525

590

700

2

190

290

290

315

335

370

410

440

490

560

630

740

n-

6-12

8-14

8-14

8-14

8-16

10-16

10-18

12-18

16-18

20-18

single seat

H

L

120

190

200

210

235

265

295

210

370

440

475

570

H1=500

862

1006

1060

1066

1137

1152

1377

1390

1394




H1=600

962

1106

1160

1166

1237

1252

1477

1490

1494




H1=700

1062

1206

1260

1266

1337

1352

1577

1590

1594

1743

1751

1790

H1=800

1162

1306

1360

1366

1437

1452

1677

1690

1694

1843

1851

1890

H1=900

1262

1406

1460

1466

1537

1552

1777

1790

1794

1943

1951

1990

H1=1000

1362

1506

1560

1566

1637

1652

1877

1890

1894

2043

2051

2090

H1=1100










2143

2150

2190

H1=1200










2243

2250

2290

H2

32

58

112

118

129

144

178

191

195

243

251

290

two-seater

H

L



200

210

235

265

295

320

370

440

475

570

H1=500



1065

1068

1147

1152

1387

1407

1419




H1=600



1165

1168

1247

1252

1487

1507

1519




H1=700



1265

1268

1347

1352

1587

1607

1619

1768

1778

1820

H1=800



1365

1368

1447

1452

1687

1607

1719

1868

1878

1920

H1=900



1465

1468

1547

1552

1787

1807

1819

1968

1978

2020

H1=1000



1565

1568

1647

1652

1887

1907

1919

2068

2078

2120

H1=1100










2168

2178

2220

H1=1200










2268

2278

2320

H2



117

120

139

144

188

208

208

268

278

320

manual regulating valve

electric regulating valve

pneumatic control valve

self-actuated regulator

control valve】It consists of an electric or pneumatic actuator and a regulating valve. Regulating valves are divided into electric regulating valves, pneumatic regulating valves, and hydraulic regulating valves (self operated regulating valves). Regulating valves are used to regulate the flow rate, pressure, and liquid level of the medium. According to the signal from the regulating position, the opening of the valve is automatically controlled to achieve the regulation of medium flow rate, pressure, and liquid level. Regulating valves are usually divided into two types: straight through single seat regulating valves and straight through double seat regulating valves. The latter has the characteristics of large flow capacity, small imbalance, and stable operation, so it is usually particularly suitable for situations with high flow rate, high pressure drop, and low leakage. The flow capacity Cv is one of the main parameters for selecting a regulating valve. The definition of the flow capacity of a regulating valve is: when the regulating valve is fully opened, the pressure difference between the two ends of the valve is 0.1MPa, and the fluid density is 1g/cm3, the flow rate per hour of the regulating valve is called the flow capacity, also known as the flow coefficient, expressed in Cv, with the unit of t/h. The Cv value of the liquid is calculated according to the following formula.


Quanli Ordering Notice: (National Standard)
1、 A: Product name, model, nominal diameter B: Medium and temperature, pressure range C: Are there any accessories, delivery time, special requirements, etc. for us to correctly select for you.
2、 If the valve model of our company has already been selected by the design unit, please place an order directly with our sales center based on the valve parameters.
3、 When the situation you are using is very important or the environment is complex, please provide design drawings and detailed parameters, and our engineers and experts will focus on reviewing and analyzing for you. We can provide you with professional solutions, including design, customization, complete sets, operation, and service. We have always been committed to being a leader in the valve industry, providing you with the latest valve knowledge, the best service, and the best technical consultants. Thank you for visiting our website【
www.quanlivalve.com】If you have any questions, you can call us and we will do our best to provide you with high-quality service. Our factory specializes in providingball valvebutterfly valvegate valveglobe valvecheck valvepressure reducing valvesafety valveMarine valvesOilfield valvesWater control valveWaiting for various types of valves.