Welcome Customer !

Membership

Help

Anhui Keli Special Cable Co., Ltd
Custom manufacturer

Main Products:

foodequippro>Products

NYCWY-0.6/1KV-3 * 120sm/70 German standard power cable

NegotiableUpdate on 02/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

NYCWY-0.6/1KV-3 * 120sm/70 German standard power cables are commonly used for power supply. Very suitable for underground installation, especially in user networks and power stations. Control the electric shock and test data system Overall, this cable is suitable as a shielding layer for grounding protection Its special corrugated concentric conductor structure can connect with more cable joints without cutting people or conductors, thus ensuring the good operation of the cable.

Product Details

NYCWY-0.6/1KV-3 * 120sm/70 German standard power cable detailed information:

Cables are typically used for power supply. Very suitable for underground installation, especially in user networks and power stations. Control the electric shock and test data system Overall, this cable is suitable as a shielding layer for grounding protection Its special corrugated concentric conductor structure can connect with more cable joints without cutting people or conductors, thus ensuring the good operation of the cable.

NYCWY-0.6/1KV-3 * 120sm/70 German standard power cable conductor structure:

Conductor: Complies with VDE0295/IEC228 Class 1 or Class 2 conductors
Circular conductor (abbreviation: r); Fan-shaped conductor

(Abbreviation: s)
_Single solid conductor
(Abbreviation: e)
Multiple stranded conductors
(Abbreviation: m)
Insulation: PVC core wire insulation, DIV4 complies with HD603.1 regulations
Core wire: Core wires are twisted together to form a cable
Concentric: Spiral shaped, external conductor twisted with bare copper wire, copper brazed connection with reduced inductance transconductance, anti spiral or braided shielding
Sheath: PVC outer sheath, DMV5 complies with HD603.1 regulations (black or customized according to customer requirements)
Working temperature: Fixed installation: -40 º C to 70 º C
Occasionally moving: -5 º C to 50 º C
Bending radius:
Single core: 15 x cable outer diameter
Multi core: 12 x outer diameter

Rated voltage
Working voltage 0.6/10KV
Test cable 4000V


Flame retardant properties: PVC self extinguishing and flame retardancy, test method B according to VDE 0472 Part 804 and IEC 60332-1 regulations
NYY-O: No green/yellow dual color grounding identification (other cores can be identified by color or numerical coding)
NYY-J: with green/yellow dual color grounding identification (other cores can be identified by color or numerical coding)

NYCWY-0.6/1KV-3 * 120sm/70 German standard power cableSpecification and Model Parameter Table:

wire gauge

Number of cores X cross-sectional area of conductor # XMM2

Conductor type

Nominal outer diameter MM

Nominal copper

Weight KG/KM

Weight of nominal cable KG/KM

8

2*10.0

re/10.0

19mm

312

650

6

2*16.0

re/16.0

21.5mm

489

850

4

2*25.0

rm/25.0

24.5mm

763

1210

8

3*10.0

re/10.0

19.5 mm

408

730

6

3*16.0

re/16.0

22mm

643

1000

4

3*25.0

rm/16.0

26mm

902

1550

4

3*25.0

sm/35.0

26mm

1003

1600

2

3*35.0

sm/25.0

27.5mm

1402

1850

2

3*35.0

sm/35.0

27mm

1190

17750

11

3*50.0

sm/16.0

29.5mm

2000

2450

20

3*50.0

sm/50.0

29mm

1723

2250

20

3*70.0

sm/25.0

34mm

2798

3350

30

3*70.0

sm/70.0

33mm

2410

2950

30

3*95.0

sm/35.0

38.5mm

3791

4550

40

3*95.0

sm/50.0

38mm

3296

4100

40

3*120.0

sm/70.0

41mm

4236

5050

300

3*120.0

sm/120.0

42mm

4786

5550

300

3*150.0

sm/70.0

45mm

5100

6000

350

3*150.0

sm/95.0

46mm

5970

6900

350

3*185.0

sm/185.0

50mm

6383

7550

350

3*185.0

sm/95.0

51mm

7383

8500

500

3*240.0

sm/120.

57mm

8242

9950