E-mail
anhuitianchang@126.com
-
Phone
18055090007,13955079573
-
Address
Tiankang Avenue South Jingliu Road West, Tianchang City, Anhui Province
Anhui Taimeirui Measurement and Control System Co., Ltd
anhuitianchang@126.com
18055090007,13955079573
Tiankang Avenue South Jingliu Road West, Tianchang City, Anhui Province
Metal shielded flexible cable for coal mining machines used in coal mines
GB12972.4-91 MT818.4-1999
This product is suitable for copper core rubber sheathed metal shielded cables used in coal mining machines and similar equipment with rated voltages of 0.66/1.14kv and 1.9/3.3kv.
Cable characteristics
1. The rated voltages U0/U are 0.38/0.66kV and 1.9/3.3kV, respectively.
2. The long-term allowable working temperature for cable conductors is 90 ℃.
3. The small bending radius of the cable is 6 times the diameter of the cable.
cable model
| model | name | purpose |
| UCPTJ MCPTJ-0.66/1.14 | Metal shielded monitoring rubber sheathed flexible cable for coal mining machine | Power connection for coal mining machines and similar equipment with a rated voltage of 0.66/1.14kv |
| UCPT MCPT-1.9/3.3 | Shielded rubber sheathed flexible cable for coal mining machine | Power connection for coal mining machines and similar equipment with rated voltage of 1.9/3.3kv |
| UCPTJ MCPTJ-1.9/3.3 | Metal shielded monitoring rubber sheathed flexible cable for coal mining machine | Power connection for coal mining machines and similar equipment with rated voltage of 1.9/3.3kv |
cable structure
| Number of cores x nominal cross-sectional area mm2 | Nominal thickness mm | Cable outer diameter mm | |||
| Power cord core | Ground wire core | Monitoring core | Power line core insulation | sheath | UCPTJ MCPTJ-0.66/1.14 |
| 3×16 | 1×16 | 1×16 | 1.5 | 5.0 | 37.1-40.8 |
| 3×25 | 1×16 | 1×16 | 1.6 | 5.0 | 41.7-45.9 |
| 3×35 | 1×16 | 1×16 | 1.6 | 5.0 | 47.2-51.9 |
| 3×50 | 1×25 | 1×25 | 1.7 | 5.3 | 51.5-56.2 |
| 3×70 | 1×35 | 1×35 | 1.8 | 5.8 | 57.9-63.0 |
| 3×95 | 1×50 | 1×50 | 2.0 | 6.4 | 56.1-71.6 |
| Note: The outer diameter of the monitoring core insulation should be equivalent to that of the power core insulation. | |||||
| Number of cores x nominal cross-sectional area mm2 | Nominal thickness mm | Cable outer diameter mm | |||
| Power cord core | Ground wire core | Monitoring core | Power line core insulation | sheath | UCPTJ MCPTJ-1.9/3.3 |
| 3×35 | 1×16 | 1×16 | 2.8 | 6.0 | 55.0-60.7 |
| 3×50 | 1×25 | 1×25 | 2.8 | 6.0 | 57.8-63.0 |
| 3×70 | 1×35 | 1×35 | 3.0 | 6.0 | 64.1-70.8 |
| 3×95 | 1×50 | 1×50 | 3.0 | 6.0 | 69.2-76.2 |
| Note: The outer diameter of the monitoring core insulation should be equivalent to that of the power core insulation. | |||||
| Number of cores x nominal cross-sectional area mm2 | Nominal thickness mm | Cable outer diameter mm | ||
| Power cord core | Ground wire core | Power line core insulation | sheath | UCPT MCPT-1.9/3.3 |
| 3×35 | 1×16 | 2.8 | 6.0 | 55.0-60.7 |
| 3×50 | 1×25 | 2.8 | 6.0 | 57.8-63.0 |
| 3×70 | 1×35 | 3.0 | 6.0 | 64.1-70.8 |
| 3×95 | 1×50 | 3.0 | 6.0 | 69.2-76.2 |