Welcome Customer !

Membership

Help

Cangzhou Kexing Instrument Equipment Co., Ltd
Custom manufacturer

Main Products:

foodequippro>Products

Cangzhou Kexing Instrument Equipment Co., Ltd

  • E-mail

    kexing1718@163.com

  • Phone

    15175717500

  • Address

    Cangzhou City, Hebei Province, China

Contact Now

Langrui Integrated Floor Thickness Tester LR-H900 Type

NegotiableUpdate on 04/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Introduction to LR-H900 Integrated Floor Thickness Tester LR-H900 Integrated Floor Thickness Tester is a portable instrument that uses electromagnetic non-destructive testing technology to measure the thickness of concrete and other non ferromagnetic media

Product Details

Introduction to LR-H900 Integrated Floor Thickness Detector Instrument
The LR-H900 integrated floor thickness detector is a portable instrument that uses electromagnetic non-destructive testing technology to measure the thickness of concrete and other non ferromagnetic media. The instrument adopts an integrated structural design, which is convenient for on-site detection. It has the advantages of simple operation, wide measurement range, and small measurement error. The outstanding feature of this instrument is that within the effective range of signal reception, the host can automatically find the position of the transmitting probe and lock the center, greatly saving measurement time.
Main functions of LR-H900 integrated floor thickness detector
The LR-H900 integrated floor thickness detector can measure the thickness of floor slabs, and its main functions are as follows: 1. The host automatically determines the direction and locks the center, greatly improving the detection efficiency;
2. The body type mechanism is convenient to use and avoids the problem of signal line failure due to frequent plugging and pulling; 3. Store floor thickness values according to components;
4. Supports both USB wired data transfer and Bluetooth wireless data transfer, making data uploading easier;
Using a 3.2-inch 65K color LCD display screen with higher resolution and better display effect, and equipped with a capacitive touch screen for more convenient human-computer interaction;
6. The product fully complies with the acceptance requirements specified in the "Code for Acceptance of Construction Quality of Concrete Structures" (GB50204-2015)
Standard, conduct qualified judgment on stored data, and provide preliminary statistical results;
7. The data analysis software equipped with the instrument can analyze the detection data and generate detection reports.
Technical parameters of LR-H900 integrated floor thickness detector
1. Test thickness range: 40mm~950mm
2. * Maximum allowable error: 40mm~300mm ± 1mm
301mm~600mm soil 2mm
601mm~950mm soil 3mm
3. Data storage capacity: This machine can store 5000 components or 500000 measurement point data.
4. LCD display screen: This instrument adopts a 3.2-inch 65K color LCD display screen with a resolution of 320X240. The display effect is better, and it is equipped with a capacitive touch screen, making human-computer interaction more convenient.
Battery: Equipped with a large capacity 3200mAh lithium-ion battery, the host can work continuously for about 24 hours, and the transmission probe can work continuously for about 25 hours.
6. LR-H900 Integrated Floor Thickness Detector Volume and Weight:
Host: Volume 235x120x130 (mm)
Weight: 880g
Launch probe: 90x87 (mm) in volume
Weight: 270g
Notes on LR-H900 Integrated Floor Thickness Detector
1. Please read this manual carefully before using this instrument.
2. Work environment requirements:
The ambient temperature ranges from 0 ° C to 40 ° C
Relative humidity:<90% RH
Electromagnetic interference: No strong alternating magnetic field and must not be exposed to direct sunlight for long periods of time; Necessary protective measures should be taken when used in damp, dusty, and corrosive gas environments.
3. Storage environment requirements:
Environmental temperature: -20 ° C~60 * C
Relative humidity:<90% RH
Store in a ventilated, cool, and dry environment, and do not expose to direct sunlight for long periods of time. If not used for a long time, regularly turn on the device for inspection and perform charging operations.
4. This instrument does not have waterproof function.
5. Avoid severe vibration and impact during use and transportation.
During use, the walkie talkie should be kept at least 1 meter away from the probe.
7. Only when there is a significant signal change displayed on the host, can the center be automatically found according to the instructions on the host LCD screen. 8. During use, ensure that the host and transmission probe have sufficient battery power.
9. Do not open the instrument casing without permission, otherwise the consequences will be borne by yourself.
Maintenance and upkeep of LR-H900 integrated floor thickness detector
1. Pre use inspection
The host enters the detection state, and the mobile host gradually approaches the transmitting probe to check if there is a significant change in the signal value.
2. Cleaning
This instrument does not have waterproof function, do not use a damp cloth to scrub! Do not use organic solvents to clean instruments and accessories! Please wipe the instrument and accessories with a clean, soft, dust-free cloth.
3. Battery
The host and transmission probe are powered by rechargeable lithium batteries, which can work continuously for about 24 hours even when fully charged. When the host is low on battery, it will prompt low battery and automatically shut down when turned on. When the transmitting probe is low on battery, the power indicator light will flash. When the prompt indicates low battery, it is necessary to charge. To ensure complete charging, please keep charging continuously for 3-5 hours and do not charge in high temperature environments.
Note:
If the host and probe are not used for a long time, the battery will experience slight power loss, resulting in a decrease in power. Recharging is necessary before use. During the charging process, the charger will generate heat, which is a normal phenomenon, and the charging environment should be kept well ventilated for easy heat dissipation. The charger provided with this device should be used for charging, as using other models of chargers may cause damage to the instrument.
4. Launch probe
Strong impacts or vibrations may cause a decrease or damage to the performance of the launch probe, so it is necessary to prevent the probe from falling from a height or being pressed under heavy objects.