JA203T Touch Screen Internal Calibration Analysis Electronic BalanceProduct Features:
5-inch color touch screen, clear and intuitive display,Human computer dialogue interface, easier to operate;
Fully automatic time triggeredinternalCalibration, optional automatic internal calibration time, supports one click calibration;
The new generation of electromagnetic force balance sensors ensures fast and stable weighing;
Specially cast aluminum shell with precision casting, comprehensively enhancing the anti-static and anti-interference ability of the balance;
Three door glass windproof cover,exceedbigOperation SpaceVisual transparency and easy operation;
Added density and weight percentage functions.
JA203T Touch Screen Internal Calibration Analysis Electronic BalanceProduct configuration:Fully automatic internalcalibrationOne click automatic calibration 5-inch color touch screenLevelIndicatorsensitivity modulationSpeed regulation
full scaleremove the peelOverload and fault alarmCountingHanging weighing RS232 interface under density and weighing percentage functions
productmodel |
JA203T |
Ja103T |
JA303T |
JA403T |
JA503T |
JA603T |
|||||
Large scale weighing |
200g |
210g |
300g |
400g |
500g |
600g |
|||||
Calibration weights |
100g |
200g |
|||||||||
Calibration method |
Fully automatic time triggered calibration, one click automatic calibration |
||||||||||
Reading accuracy |
0.001g |
||||||||||
Standard deviation of repeatability error |
±0.003g |
||||||||||
linearity error |
±0.003g |
||||||||||
stabilitytime |
≤3 seconds |
||||||||||
ambient temperature |
5-35℃ |
||||||||||
unit conversion |
g,oz,ct... |
||||||||||
Pan size |
Φ80mm |
||||||||||
Windproof cover size |
240x190x265mm |
||||||||||
External dimensions |
365x205x350mm |
||||||||||
Package size |
Inner box: 415 × 285 × 430mm Outer box: 475 × 315 × 485mm |
||||||||||
Optional parts |
Printer |
||||||||||
gross weight |
11kg |
||||||||||
Excluding tax transportation |
2550 |
2500 |
2600 |
2600 |
2700 |
2800 |
|||||

Maintenance and upkeep of electronic scales
① Place the balance on a stable workbench to avoid vibration, airflow, and sunlight exposure.
② Adjust the level bubble to the middle position before use.
③ The electronic balance should be preheated according to the instructions.
④ When weighing volatile and corrosive items, they should be stored in a sealed container to prevent corrosion and damage to the electronic balance.
⑤ Regularly perform self calibration or external calibration on electronic scales to ensure they are in good condition.
⑥ If the electronic balance malfunctions, it should be repaired in a timely manner and should not be operated with 'illness'.
⑦ The balance should not be overloaded during operation to avoid damage to the balance.