Welcome Customer !

Membership

Help

Guangzhou Puyuan Scientific Instrument Co., Ltd
Custom manufacturer

Main Products:

foodequippro>Products
Product Categories

Guangzhou Puyuan Scientific Instrument Co., Ltd

  • E-mail

  • Phone

    135-3505-5226

  • Address

    Room 101, No. 76 Yindingtang Back Street, Tianhe District, Guangzhou City

Contact Now

Ionic chromatograph Dionex ICS-900

NegotiableUpdate on 07/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Ionic chromatograph Dionex ICS-900

Product Details

ICS-900 ion chromatography instrument parameters:


Technical indicators:


pump
Flow rate range: 0.00-5.00 mL/min, at 0.01mL/
Min is the increment, set by the computer system and monitored by the instrument
Types of parameters.
Maximum pump pressure: 5000psi (35Mpa)
Traffic accuracy:<0.1%
Traffic accuracy:<0.1%
Pressure fluctuation:<1%
Pressure required for rinsing solution bottle: No gas external pressure required
High performance/low pulse dual plunger pump, made of non-metallic PEEK material
Flow system.

Conductivity detector:
Type: Digital Conductivity Detector
Detection range: Digital mode 0-10000 μ S/cm
Controllable temperature mode of conductivity cell: bipolar pulse
Temperature stability of conductivity cell:<0.01 degrees
Electronic drift:<5 nS/h (full range)
Resolution: 0.0047 nS/cm
Maximum pool operating pressure: 10MPa (1500psi)
Data output method: USB high-speed communication interface, with self
Dynamic recognition function
Cell electrode: Inert 316 stainless steel microelectrode
Pool body: chemically inert PEEK polymer material
The detector is compatible with methane sulfonic acid

injector
Manual injection valve:
Using American Rheodyne electric full PEEK material high-pressure six
Valve (without any auxiliary gas)
Quantitative injection loop: 10 μ L (standard configuration),
20/50/100/250/500 μ L (optional)
Automatic sampler (optional):
Capacity: Simultaneously hold 66 5 mL or 88 0.5 mL samples
Equipped with automatic online concentration/filtration/solid-phase extraction (to remove organic compounds)
Pollution and other pre-treatment functions
Maximum injection speed: 4 mL/min (5mL bottle)
Maximum sample pretreatment speed: 1.0 mL/min (5 mL bottle)
Maximum injection pressure: 690 Kpa (100 psi/0.7 MPa)
The sample disk has no rotating parts and is designed to be simple and reliable, making
Convenient/reliable to use.

Rinse solution device
Rinse solution bottle: Standard configuration includes 2 sets of high-strength plastic 2 liters for rinsing
Liquid bottle (optional 4 L)
Equipped with fully sealed and protective gas function (user's own)
Choose to use). Completely isolate the external air (CO2),
Ensure that the configured rinsing solution can be stored stably for a long time with high concentration
There is no change.
Dimensions (height x width x length): 33 x 24 x 40 (13 x 9.5 x 15.75 in.)
Weight: 10 Kg (22 lbs)

Suppressor:
Compatible with three modes: electrolytic self circulation, electrolytic external water supply, and chemical suppression, without the need for peristaltic pumps or vulnerable parts.
Suppressor dead volume:<50 μ L

Chameleon software:
Chameleon software has information tracking and monitoring functions, compatible with WINDOWS 2000/XP and VISTA systems;
The software can set automatic power on/off.

Product features:

In order to adapt to different fields and analysis needs, meet users' daily applications and market popularity, Dian Company officially launched the ICS90 ion chromatography in 2003, which condenses numerous high-tech patented technologies. This model has a high performance/price ratio.
World leading suppressor technology
In 1975, Dian Company was the first to develop and produce suppressors, thus ushering in the era of modern ion chromatography. To this day, Dian Company has developed 6 generations of suppressors with patented technology and has been leading the world in the highest level of suppressor technology.
Diane is the only manufacturer that can provide both negative and positive membrane suppressors simultaneously. The automatic regeneration biofilm suppressor produced by it has the advantages of high suppression capacity, no need for peristaltic pumps, fast balance, anti pollution, exquisite structure, small size, good repeatability, zero maintenance, simple operation, and low price.
World leading analytical column technology
Diane is the only company in the world that only uses ion chromatography columns developed and produced in-house. The ion chromatography column of Dian Company has the characteristics of high column efficiency, high column capacity, long service life, good organic compatibility, and strong anti pollution. It can be used in the pH range of 0-14. 100% compatibility with organic solvents can greatly improve the solubility/selectivity/anti contamination of samples, expand their application range, and extend their service life (3-5 times that of ordinary analytical columns). The unique high-capacity analytical column of Dian Company has an exchange capacity 2-100 times higher than ordinary columns, greatly improving the ability to analyze complex samples/components with significantly different retention characteristics. It further extends the service life of the column (2-4 times that of ordinary analytical columns), improves the quantification of weakly retained components, and enables analysis of ppb level samples with large volume injection. ICS90 can use various analytical columns from Dian Company, with commonly used columns being AS9-HC, AS14A, and CS12A, CS16. The column capacity of the CS16 cation analysis column, which is grafted and agglomerated with ion exchange functional groups, can reach up to 8400 umicro/mol, which is 50-100 times the column capacity of similar analysis columns from other manufacturers

Product Description:

The dual piston pulse infusion pump system has a wide flow rate range, low maintenance costs, and long operating time
Advanced digital conductivity detectors have high sensitivity and stability, making the measurement results more accurate
Advanced biofilm suppression technology
The patented high-capacity automatic continuous regeneration microfilm chemical inhibition technology can be used for both anions and cations. Dian Company is the only manufacturer that can provide two types of microfilm suppressors simultaneously. The MMS suppressor using the latest development of DCR (Automatic Cycle Regeneration) technology has no baseline drift, is easy to operate, and has extremely low operating costs.

Advanced chromatographic column technology
World advanced ion chromatography column with high efficiency and capacity, suitable for various purposes.
Advanced software control and data processing methods
The Chromeleon SE chameleon control analysis software can fully control the instrument, monitor operating conditions and parameters. Users only need to turn on/press the mouse, enter the sample name/selection method/press the run button in the CHROMELECON SE browser window, and the instrument will automatically run and process the data, and print the report automatically. The low-speed RS-232 interface has been removed and replaced with a USB high-speed data transmission connection interface, which can automatically recognize and connect with various other optional components. Fully comply with the requirements of LIMS laboratory automatic management system.
Advanced automatic sampler and IN LINE sample processing device.
The optional AS40 automatic sampler can automatically complete pre-treatment functions such as concentration/filtration/solid-phase extraction (removal of organic contamination) of samples online (IN LINE). The maximum number of samples placed at once is up to 88, which is particularly suitable for users with large sample batches. The AS40 automatic sampler can use the most advanced and best sample processing technology currently available - solid-phase extraction technology. Users only need to choose different extraction columns, which can easily, inexpensively, and effectively automatically process complex or contaminated samples. The extraction column in solid-phase extraction technology has now been localized and priced more affordably