Inductively Coupled Plasma Emission Spectrometer
Model: ICP-3000
Product Description, Technical Parameters, and Configuration
ICP-3000 inductively coupled plasma emission spectrometer is a high-performance full spectrum direct reading spectrometer developed by Tianrui Instrument Company after years of technical accumulation. It is used to determine the content of trace and trace elements in different substances (soluble in hydrochloric acid, nitric acid, hydrofluoric acid, etc.). High degree of automation, easy operation, stable and reliable. At present, instruments are widely used in various fields such as rare earth, geology, metallurgy, chemical engineering, environmental protection, clinical medicine, petroleum products, semiconductors, food, biological samples, criminal science, agricultural research, etc.
performance advantage
Fully automated design
Except for the power switch, all functions of the entire instrument are controlled by a computer, which is reliable, safe, and convenient.
peristaltic pump
The peristaltic pump is designed with twelve rotors and four channels for fully automatic operation, and the rotational speed of the peristaltic pump can be adjusted according to the required flow rate; By using a peristaltic pump to smoothly inject and remove waste liquid, the injection speed is ensured to be consistent with the waste liquid removal speed. Customers can adjust the speed as needed to ensure the stability of the injection system.
Automatic control of gas flow rate
In the injection system, the carrier gas, plasma gas, and auxiliary gas are all controlled by advanced mass flow controllers (MFCs), which have the advantages of continuously adjustable flow rate and stable flow rate, ensuring the stability of the injection system and laying a solid foundation for the stability of the light source.
Stable and advanced all solid state RF power supply
The RF power supply used in the instrument is a fully solid-state RF power supply independently developed by Tianrui Instrument, which has many advantages such as small size, high efficiency, stable output power, and various protection functions, further improving the stability and safety of the instrument.
Fast and accurate fully automatic matching function
The load terminal adopts the fully automatic matching technology independently developed by Tianrui Instrument, which has the advantages of fast matching speed and high accuracy, ensuring that the output power is maximally applied to the load, improving the efficiency of power supply, thereby enhancing the stability of the instrument, and making the entire ignition process simple and convenient.
Advanced sampling system
The injection system is efficient and stable, and can be equipped with various atomizers and atomization chambers at home and abroad. It can also be equipped with high salt atomizers, hydrogen fluoride resistant atomizers, etc., to meet various customer needs; At the same time, Tianrui's independently developed automatic sampler makes testing operations more convenient and further improves testing efficiency.
Unique and precise optical system
Adopting a mid step grating prism cross dispersion method, professional optical optimization design maximizes the luminous flux while ensuring excellent spectral resolution; No moving optical components, ensuring good long-term stability; The ultra-low stray light design combined with unique optical design greatly reduces the interference of background light and further improves the detection limit; The efficient nitrogen distributed purging chamber, combined with high-quality optical components, ensures the measurement of elements such as P, S, and As in the deep ultraviolet region.
Accurate wavelength positioning
Intelligent and precise automatic wavelength calibration algorithm enables measurement without the need for additional peak calibration, ensuring accurate measurement while saving a lot of standard solution and measurement time.
A detector with excellent performance
Adopting large-sized CID detectors, advanced, mature, and stable; Large target size, millions of pixels; Continuous coverage in the range of 165-900nm, one exposure, full spectrum display; The non-destructive reading (NDRO) function improves the signal-to-noise ratio of weak analysis lines, enhances the accuracy of results, and outperforms CCD in both data acquisition and analysis; The excellent linear dynamic range and inherent anti overflow function ensure that any strong or weak spectral line can be measured and analyzed within one exposure, while providing flexibility for selecting the ideal wavelength for the method (second, third, or higher sensitive lines can be selected to eliminate interference).
Ultra fast testing speed
Each analytical spectral line can be optimized for measurement by setting any suitable integration period within the exposure time; It can read out the intensity integral values of all analyzed spectral lines in one exposure to accelerate the analysis speed; It is also possible to specify independent readout of spectral lines, with a readout time not exceeding 2ms.
Powerful software analysis capabilities
The software is easy and intuitive to operate, with qualitative, semi quantitative, and quantitative analysis functions, instrument diagnostic optimization functions, flexible full spectrum research functions, powerful offline reprocessing functions, and scientific and intelligent background correction and interference removal algorithm functions, making testing more professional and accurate.
Technical Specifications
Technical specifications of RF generator
Input power supply: AC 220V, current 20A
Output power: 700~1600W
Adjustment accuracy: 2W
Frequency stability:<0.05%
Output power stability:<0.1%
Matching method: automatic matching
Electromagnetic field leakage radiation intensity: Electric field intensity E at a distance of 30cm from the chassis:<0.5V/m
Technical specifications of injection device
Output working coil: inner diameter 25mm, 3 turns
Three concentric quartz torch tube: outer diameter 20mm; multiple models available according to the size of the central channel
Efficient imported atomizer: concentric atomizer with an outer diameter of 6mm; Multiple models to choose from, high salt, HF resistant, etc
Atomization chamber: Double cylinder atomization chamber, optional swirl atomization chamber, outer diameter 57.2mm
Peristaltic pump: twelve rotors and four channels, the speed can be adjusted according to the required flow rate (i.e. set according to the injection speed, intuitive and accurate)
Total argon consumption: The total consumption of argon is less than 14L/min
Specification of argon flowmeter and carrier gas pressure gauge: 1. Plasma gas flowmeter (100~1000) L/h (1.6~16L/min)
2. Auxiliary gas flow meter (6~60) L/h (0.1~1L/min)
3. Carrier gas flow meter (6~60) L/h (0.1~1L/min)
4. Carrier gas stabilizing valve (0.2MPa)
5. Cooling water: water temperature of 20-25 ℃, flow rate>5L/min, water pressure>0.1MPa
Technical specifications of spectrometer
Grating: Medium step grating, 52.67 lp/mm, 64 blaze angle, using a thermal expansion coefficient close to zero from Schott GmbH in Germany
Zerodur material as the substrate, with superior performance
Prism: ultrapure Corning ultraviolet fused silica, with a transmissivity of 99.6% at 170nm
Wavelength range: 165nm~900nm
Focal length: 430mm
Numerical aperture: F/8, ultra-high luminous flux ensures the detection limit and sensitivity of the instrument
Resolution:< 0.0068nm@200nm
Scattered light: Equivalent background concentration of 10000ppmCa solution at As189.042nm<2ppm
Light chamber: precision constant temperature, 35 ± 0.1 ℃
Distributed nitrogen purging, normal purging 2L/min, rapid purging 4L/min
Technical specifications of detection device
Detector type: Charge Injection Detector (CID)
Target surface size: 27.6mm × 27.6mm, 1024 × 1024 addressing detection unit
Reading methods: Non destructive reading (NDRO), full frame reading (FF), and arbitrary reading integration (RAI)
Linear dynamic range: 108
Wavelength response range: 165nm~1000nm
Electronic shutter: set the integration time for each spectral line separately; Can specify independent readout of spectral lines, with readout time<2ms
Quantum efficiency: No coating, reaching over 35% in the 200nm ultraviolet region
Detector cooling: efficient three-stage semiconductor cooling, cooling temperature -45 ℃
Instrument technical specifications
Observation method: Vertical observation
Liquid content: 0.01ppm~several thousand ppm
Solid content: 0.001%~70%
Repeatability: (i.e. short-term stability) relative standard deviation RSD<0.5%
Stability: Relative standard deviation RSD<1% @ 2 hours
Testing speed: The reading time for a single spectral line CID is only 2ms, and all elements can be measured within one minute
Element detection limit (μ g/L): Most elements are 1ppb~10ppb
Instrument size: desktop 1300mm * 840mm * 740mm
Application field
1. Silicon industry: magnetic material processing industry
2. Metallurgical industry: It can analyze impurity elements such as As, Bi, Pb, Sb, Sn that have a significant impact on the quality of metal materials
3. Water quality analysis: can detect eight heavy metals and other elements that cause water pollution
4. Geological and ore analysis: determination of Ca, Mg, Na, Fe, Cu, Mn, Zn, Co, Ni, Au, Ag and other elements in rock samples
5. Applications in the petrochemical and light industry fields: Testing more than 30 elements in crude oil, mainly including Fe, Na, Mg, Ni, V, Ca, Pb, Mo, Mn, Cr, Co, Ba, As, etc
6. Medical, health, agricultural environmental protection, commodity, and food quality testing