Coating thickness gauge X-Strata920 series


Coating thickness gauge X-Strata920series

Coating thickness gaugeX-Strata920Series, belonging toXX-ray fluorescence coating thickness measuring instrument, widely used inPCBTheFPCTheLEDTheSMTMeasurement of surface coating thickness and material analysis for industries such as connectors, terminals, hardware products, automotive parts, sanitary ware, jewelry, etc;It is an ideal testing tool for measuring the thickness of coatings on various electroplating products.

Coating thickness gaugeX-Strata920The series has a high cost-effectiveness ratio and features non-destructive, non-contact, multi alloy measurement, wide range of measurement elements, accurate measurement, and short measurement time; It has high productivity, high reproducibility, can effectively control product quality, and save electroplating costs.

Coating thickness gaugeX-Strata920Job characteristics:

l High measurement accuracy and good stability, with measurement results accurate to μ min

l Fast non-destructive measurement, short measurement time,10Obtain measurement results within seconds

l Qualitative, semi quantitative, and quantitative analysis

l Conduct precious metal testing, such asAu karatevaluate

l Material identification and classification testing, analysis of materials and alloy elements, qualitative analysis of element spectra

l Powerful data statistics and processing functions: mean, standard deviation, relative standard deviation, maximum value, minimum value, data variation range, data numberCPTheCPKControl upper limit chart, control lower limit chart, data groupingX-bar/RCharts and histograms

l Result output: direct printing or one click export toPDFTheExcelDocuments; The report includes data, images, statistical charts, customer information, etc

l Measurement position preview function; High resolution colorCCDThe sample observation system has a standard optical magnification of30times

l Laser focusing and autofocus functions; Click the mouse,ZAxis automatic scanning, laser focusing

instrument parameters

model

P920-S

P920-MWS

P920-MWM

P920-AM

name

semi-automatic

Automatic platform

Fixed table

Single collimator deepening table

Multi collimator deepening table

sample image

Measurement element range

Ti22---U92

Coating and Composition Analysis

l Coating: up to simultaneous measurement5Layer(4Layer coating+Base material) coating

l Ingredients: Maximum simultaneous measurement25Seed elements

measurement method

l SmartLinkaFP(Basic Parameter Method)

l Instrument pre installed exceeds800Application parameters/method

l Simple and intuitive steps to build an application

XX-ray excitation

l 50kVThe1.0mA(50W)

l Air cooling micro focusWtargetXX-ray tube,Bewindow

l Vertical downward illuminationXX-ray optical system

l Safety anti radiation shutter

l Secondary filtering component, optional with three programmable exchange filters, effectiveYuXCorrection of X-ray overlap spectrum

imaging system

l Color video system

l Optical amplification:30Multiple, optional50times

l Digital Zoom200%

l Laser autofocus

l Real time display function of the tested sample image

computer system

l Intel Core i3-3240 3.40GHz, Memory2G, hard drive500G,DVDoptical disc drive

l 17Inch LCD color display

l MicrosoftTM Win7 32bit

Sample table specifications

l Measure sample height ≤33mm

l Measure sample height ≤160mm

l Internal dimensions of sample chamber (width)×deep×High):279×508×152mm

l Sample compartment drawer design,4Adjustable position up and down, height per grid25.4mm

l Custom Sample Stand: Higher sample stands can be provided according to customer requirements to meet sample height requirements160mmThe measurement

l Measure sample height ≤33mm

l X-Yaxistrip:wide×deep178×178mm

l Sample table size:wide×deep610×560mm

l Automatic sample delivery, unmanned automatic measurement

l Programming control of samples, automatic multi-point testing, and repeated testing

l Mouse controlled sample stage for precise positioning of samples

Instrument appearance

wideX deep Xhigh

407×770×305mm

407×770×400mm

610×1037×375mm

Zaxis

Use mouse control to program movement distance43mm

Collimator specifications

l Optional single collimator and multiple collimators

l Multi collimator programmable switching

l Optional circular and rectangular collimators

l Circular collimator:Ø0.1TheØ0.15TheØ0.2TheØ0.3TheØ0.33TheØ0.5mm

l Rectangular collimator:0.025x0.05The0.05x0.05The0.013x0.254The0.254x0.254The0.051x0.254The0.102x0.406mm

l Standard configuration of single collimator:Ø0.3mm

l Dual collimator standard:Ø0.1TheØ0.3mm

l Standard configuration of four collimators:Ø0.15TheØ0.3The0.05x0.05The0.051x0.254mm

detector

Proportional counter

working principle

Launch a beam once on the tested sampleXRadiation, atomic absorption of samplesXThe energy of the radiation is excited and released twiceXRay. Each chemical element releases specific energyXRay. By measuring these released secondary substancesXThe characteristic energy and intensity of radiation,XThe X-ray analyzer can provide qualitative and quantitative analysis of the coating thickness and composition of the tested material

safety

l Automatic locking function to prevent unauthorized operations

l Simple user interface only allows limited authorization to daily operators

l Supervisors can perform system maintenance

l The system automatically generates usage records for operators

l ZAxis protection sensor

l Safety anti radiation shutter

l Sample room door opening and closing sensor

l XRay lock

l XRadiation warning light

l Emergency stop button

l Front panel safety button and rear panel safety lock

Result output

l direct printing

l One click export toPDFDocumentsExcelDocuments (optional);

l Custom report template, the report package can include data, images, statistical charts, customer information, etc;

l Statistical data, charts, and tables contain mean, standard deviation, relative standard deviation, maximum value, minimum value, range of data variation, and data numberCPTheCPKControl upper limit chart, control lower limit chart, data groupingX-bar/RCharts, histograms, etc