E-mail
anyuan58@126.com
- Phone
-
Address
No.1 Minke East Road, Shiqi District, Zhongshan City
Zhongshan Anyuan Instrument Co., Ltd
anyuan58@126.com
No.1 Minke East Road, Shiqi District, Zhongshan City

| Hole and surface copper thickness gauge CMI760 | ||||||||||||||||
|
Copper thickness gauge for holes and surfaces CMI700series
CMI760yesCMI700The series is designed to meet the needs of copper thickness measurement and quality control in the printed circuit board industry; Measure the thickness of copper plating on the surface and inside the holes using micro resistance and eddy current methods. It has multifunctionality, high scalability, and advanced statistical functions, which are used for data organization and analysis.
700 SERIESHost parameters:
l save store Quantity:8000Byte, non-volatile l ruler Inch: Length×wide×high292.1×270×140mm l heavy Quantity:2.79Kg l electricity Source:AC220V l Unit Conversion: Automatic Conversion between Imperial and Metric Systems with One Button l single Position: Optionalmils TheμmTheμinThemmTheinor%To display units l pick up 口:RS-232 Serial interface, adjustable baud rate, used for downloading to a printer or computer l apparent Display: Large with backlight and wide viewing angleLCDLCD display screen,480(H)×32(V)pixel l Statistics show: number of measurements, standard deviation, mean, maximum value, minimum value l Statistical report: requires configuration of a serial printer orPCComputer download, storage location, number of measurements, copper foil type, linear copper wire width, measurement date/Time, mean, standard deviation, percentage variance, accuracy, highest value, lowest value, range of values,CPK Value, individual reading, timestamp, histogram l image Table: Histogram, Trend Chart,X-R image
SRP-4Copper probe parameters:
l Accuracy:5%,Reference standard film l Accuracy: Chemical copper: Standard deviation0.2 %,Electroplated copper: standard deviation0.3 % l Resolution:0.1μm≥10μm,0.01μm<10μm,0.001μm<1μm,0.01mils≥1 mil,0.001mils<1mil l Thickness measurement range: Chemical copper:0.25μm–12.7μm(10μin-500μin) Electroplated copper:2.5μm–254μm(0.1miles–10miles) l Linear copper wire width range:203μm–7620μm(8miles–300miles l Job characteristics:Apply advanced micro resistance testing technology. The tethered probe consists of four probes,ABFor the positive electrodeCDFor negative electrode; When measuring, there will be a small resistance in the current from the positive pole to the negative pole. The surface copper thickness can be accurately and reliably obtained through the functional relationship between the resistance value and the thickness value, without being affected by the insulation board layer and the copper layer on the back of the circuit board. DepletedSRP-4The probe can be replaced by itself and is a patented product of Oxford Instruments. The illumination function and protective cover of the probe facilitate accurate positioning during measurement.
ETPCopper probe parameters:
l Accuracy:5%,Reference standard film l accuracy:1.2 mil When,1% (Under typical circumstances) l Resolution:0.01 mils (0.25 μm) l Eddy current: comply withASTM E37696 Related regulations of standards l Measurement thickness range:2--102μm (0.08 -- 4.0 mils) l Minimum diameter of hole:Φ35 mils (Φ899 μm) l Aperture range:Φ0.899 mm--Φ3.0 mm l Job characteristics: Apply eddy current testing technology. When measuring, the probe releases electromagnetic waves. When the magnetic field cuts the metal layer, a change in the magnetic field occurs. By calculating this change, the copper thickness of the hole wall can be determined. Measurement is not affected by the inner layer of the board, even for double-layer or multi-layer boards, and even in the presence of tin or tin/Under the condition of a lead protective layer, it can also work well. In addition, the probe adopts temperature compensation technology, which can measure the thickness of copper holes even for plates that have just been taken out of the plating tank. Principle of eddy current |
||||||||||||||||