Welcome Customer !

Membership

Help

Beijing Huayi Tongtai Environmental Protection Technology Co., Ltd
Custom manufacturer

Main Products:

foodequippro>Products

Beijing Huayi Tongtai Environmental Protection Technology Co., Ltd

  • E-mail

  • Phone

    13261731718

  • Address

    Mingliu Future Building, Majiabao West Road, Fengtai District, Beijing

Contact Now

HANNA HANNA HI4521 Multi Parameter Water Quality Analyzer from Italy

NegotiableUpdate on 05/17
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The HI4521 series is a dual channel measurement, high-precision laboratory analysis and determination instrument.

Product Details

HANNA HANNA HI4521 Multi Parameter Water Quality Analyzer from Italy Product Introduction:

The HI4521 series is a dual channel measurement, high-precision laboratory analysis and determination instrument.

HANNA's unique Cal Check TM calibration diagnostic system can assess the performance of electrical and buffer solutions during the calibration process. If the measurement exceeds the calibration range of the system, a new calibration delay or an error in the calibration solution will emit a beep sound to the user. Each instrument can be assigned a unique ID code. In any mode, users can use the HELP key to access on-screen help. Unique anti-interference design can effectively prevent interference and instability caused by electromagnetic signals. The instrument is equipped with USB and RS232 interfaces, making it convenient for users to connect to computers of different configurations. By selecting HI92000 WINDOWS software and corresponding data cables, data transmission can be carried out for further analysis and management of the data.

HANNA HANNA HI4521 Multi Parameter Water Quality Analyzer from Italy Product Features:

1. HI 4521 240 x 320 color display screen
2. HI 4521 can display chart curves and real-time storage
3. HI 4521 USB/RS232 data interface
4. Humanized operation interface
5. GLP data management function
6. Manual or automatic temperature compensation
7. Dual channel, multi parameter measurement
8. Information prompt menu and intuitive navigation operation
9. Equipped with an electrical bracket, especially suitable for laboratory operations

PH Characteristics
1. Unique Calibration Check ™ Calibration diagnostic system
2. Many 5-point calibrations with built-in calibration points and user-defined calibration points

Conductivity related characteristics EC Features
1. Multiple measurement ranges for conductivity, resistivity, total dissolved solids, and salinity
2. Automatic identification of battery level, fixed battery measurement
3. Resolution 0.001 μ S/cm to 1 mS/cm
4 USP<645>
USP: 1, 2, 3 step measurement
5. 3 salinity ranges: actual salinity, natural seawater salinity, percentage salinity
6. Linear and nonlinear temperature compensation



HANNA HANNA HI4521 Multi Parameter Water Quality Analyzer from Italy Product Parameters:

pH

measuring range

-2.0-20.0 pH;-2.00-20.00 pH; -2.000-20.000 pH


resolution

0.1 pH;0.01 pH; 0.001 pH


accuracy

±0.1 pH;±0.01 pH;±0.002 pH


Calibration Mode

Automatic 5-point calibration, with 8 built-in calibration points (pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) and 5 user-defined calibration points


redox

measuring range

±2000.0 mV


resolution

0.1 mV


accuracy

±0.2 mV


Calibration Mode

Acidity automatic calibration, built-in 8 standard calibration points and 5 user-defined calibration points;
8 calibration points: 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45 pH


conductivity

measuring range

0.000-9.999 µS/cm; 10.00-99.99 µS/cm; 100.0-999.9 µS/cm; 1.000-9.999 mS/cm; 10.00-99.99 mS/cm; 100.0-999.9 mS/cm; 1000 mS/cm with seven measurement ranges


resolution

0.001 µS/cm; 0.01 µS/cm; 0.1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm


accuracy

± 1% of the reading (± 0.01 µ S/cm)


Calibration Mode

Automatically identify built-in calibration points or use user-defined calibration points for calibration


resistivity

measuring range

Seven measurement ranges: 1.00-99.99 Ω• cm; 100.0-99.99 Ω• cm; 1.000-9.999 k Ω• cm; 10.00-99.99 k Ω• cm; 100.0-99.99 k Ω• cm; 1.00-99.99 M Ω• cm; 10.0-100.0 M Ω• cm


resolution

0.01 Ω•cm;0.1 Ω•cm;0.001 kΩ•cm;0.01 kΩ•cm;0.1 kΩ•cm;0.01 MΩ•cm;0.1 MΩ•cm


accuracy

± 2% of the reading (± 1 Ω• cm)


temperature compensation

Conductivity compensation is: linear or nonlinear automatic temperature compensation


TDS

measuring range

0.000-9.999 ppm; 10.00-99.99 ppm; 100.0-999.9 ppm; 1.000-9.999 ppt; 10.00-99.99 ppt; 100.0-400.0 ppt six measurement ranges


resolution

0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt


accuracy

± 1% or ± 0.01 ppm of reading


TDS/EC conversion coefficient

0.40-1.00


salinity

measuring range

Actual salinity: 0.00-42.00; Salinity of seawater: 0.00-80.00 ppt; Percentage salinity: 0.0-400.0%


resolution

0.01; 0.1%


accuracy

± 1% of the reading


Calibration Mode

Percentage salinity single point calibration


temperature

measuring range

-20.0-120℃; -4.0-248.0°F;253.15-393.15K


resolution

0.1℃; 0.1°F;0.1K


accuracy

±0.2℃; ±0.4°F;±0.2K


Calibration Mode

3-point calibration


Basic indicators

measurement channel

One pH/mV/ISE channel and one EC channel


End point locking

Automatic endpoint locking


Data Storage

Automatic or manual storage, 10 sets, 5000 data per set


Data interface

USB/RS232 data interface


screen display

240 × 320 dot matrix color display screen, with functions such as on-screen assistance and user confirmation


Power Mode

AC220/12VDC power adapter


Size/Weight

Host: 159 × 230 × 93 mm/800 g


Choosing power distribution is very important

Acidity/Redox

HI1131B can be filled with glass composite acidity and is used for routine solution measurement in the laboratory


HI1200B non fillable plastic composite acidity meter, used for laboratory and on-site routine solution measurement


HI1300B non fillable plastic composite acidity meter, used for laboratory and on-site pure water measurement


HI3131B can be filled with glass ORP electrode, applied for laboratory redox potential measurement


EC/TDS/NaCl

HI76312 conductivity/resistivity/TDS/salinity four ring electrode, applied to laboratory EC/TDS/NaCl measurement


temperature

HI7662-T high-precision temperature probe


Product configuration of HANNA HANNA HI4521 multi parameter water quality analyzer from Italy:

Standard configuration

HI4521

Host, HI1131B refillable glass composite acidity sensor (BNC interface, wire length: 1 meter), HI7071S customized special electrolyte filling solution (30ml), HI76312 built-in temperature sensor four ring EC/TDS electrolyte, HI7662T stainless steel temperature probe (wire length: 1 meter), HI70004 (pH4.01, 20mL), HI70007 (pH7.01, 20mL) acidity standard buffer solution, HI76404N customized special electrolyte bracket, HI710006/8 power adapter, Chinese English user manual, HE721004 customized special instrument carrying case

HI4521P

Host, HI1131B refillable glass composite acidity sensor, HI7071S filling solution, HI76312 built-in temperature sensor with four rings EC/TDS, HI7662-T stainless steel temperature probe, randomly bagged acidity standard buffer solution, HI76404N special bracket for electricity, Chinese and English user manual, HE721004 customized special instrument carrying case

HI4521B/C

Host, HI1131B/C glass composite acidity sensor, HI76312 built-in temperature sensor with four ring EC/TDS sensor, HI7662-T stainless steel temperature probe, randomly packaged acidity standard buffer solution, HI76404N specialized bracket for acidity sensor, Chinese and English user manual, HE721004 customized special instrument carrying case

HI4521C

Host, HI1230B/C plastic composite acidity sensor (BNC interface, wire length: 1 meter), HI76312 built-in temperature sensor four ring EC/TDS sensor, HI7662T stainless steel temperature probe (wire length: 1 meter), HI70004 (pH4.01, 20mL), HI70007 (pH7.01, 20mL) acidity standard buffer solution, HI76404N customized special electrical bracket, HI710006/8 power adapter, Chinese English user manual, HE721004 customized special instrument carrying case

HI4521PC

Host, HI1230B plastic composite acidity sensor, HI76312 built-in temperature sensor with four rings of EC/TDS sensor, HI7662-T stainless steel temperature probe, randomly bagged acidity standard buffer solution, HI76404N special bracket for acidity sensor, Chinese and English user manual, HE721004 customized special instrument carrying case

optional accessories

HI1043

Fillable glass composite with high acidity and electrical conductivity

HI1053

Cone shaped head can be filled with glass composite acidity electricity

HI1083

Ultra fine round glass composite with high acidity and electrical conductivity

HI1131

Fillable glass composite with high acidity and electrical conductivity

HI1230

Plastic composite with high acidity and electrical conductivity

HI3230

Plastic composite redox charge

HI76312

Built in temperature sensor with multiple parameters and four ring electrical system

HI7662

Stainless steel temperature probe

HI54710

Laboratory grade acidity calibration group

HI5004

Laboratory Test Certificate Acidity Standard Buffer Solution

HI5007

Laboratory Test Certificate Acidity Standard Buffer Solution

HI5010

Laboratory Test Certificate Acidity Standard Buffer Solution

HI7020

Redox standard buffer solution

HI7021

Redox standard buffer solution

HI7022

Redox standard buffer solution

HI7091

Redox standard buffer solution

HI7092

Redox standard buffer solution

HI7071

Conventional electric filling fluid

HI7061

Conventional electric cleaning solution

HI70300

Electric preservation solution

HI920010

5-9-pin RS232 data transmission cable

HI92000

Data processing management software

HI920014

data transmission line

prompt

The HI4521 standard configuration only includes EC/TDS/NaCl batteries and does not include acidity batteries, or according to the corresponding model standard configuration price description