Phone
13261731718
-
Address
Mingliu Future Building, Majiabao West Road, Fengtai District, Beijing
Beijing Huayi Tongtai Environmental Protection Technology Co., Ltd
13261731718
Mingliu Future Building, Majiabao West Road, Fengtai District, Beijing
HANNA HANNA HI4521 Multi Parameter Water Quality Analyzer from Italy Product Introduction:
The HI4521 series is a dual channel measurement, high-precision laboratory analysis and determination instrument.
HANNA's unique Cal Check TM calibration diagnostic system can assess the performance of electrical and buffer solutions during the calibration process. If the measurement exceeds the calibration range of the system, a new calibration delay or an error in the calibration solution will emit a beep sound to the user. Each instrument can be assigned a unique ID code. In any mode, users can use the HELP key to access on-screen help. Unique anti-interference design can effectively prevent interference and instability caused by electromagnetic signals. The instrument is equipped with USB and RS232 interfaces, making it convenient for users to connect to computers of different configurations. By selecting HI92000 WINDOWS software and corresponding data cables, data transmission can be carried out for further analysis and management of the data.
HANNA HANNA HI4521 Multi Parameter Water Quality Analyzer from Italy Product Features:
1. HI 4521 240 x 320 color display screen
2. HI 4521 can display chart curves and real-time storage
3. HI 4521 USB/RS232 data interface
4. Humanized operation interface
5. GLP data management function
6. Manual or automatic temperature compensation
7. Dual channel, multi parameter measurement
8. Information prompt menu and intuitive navigation operation
9. Equipped with an electrical bracket, especially suitable for laboratory operations
PH Characteristics
1. Unique Calibration Check ™ Calibration diagnostic system
2. Many 5-point calibrations with built-in calibration points and user-defined calibration points
Conductivity related characteristics EC Features
1. Multiple measurement ranges for conductivity, resistivity, total dissolved solids, and salinity
2. Automatic identification of battery level, fixed battery measurement
3. Resolution 0.001 μ S/cm to 1 mS/cm
4 USP<645>USP: 1, 2, 3 step measurement
5. 3 salinity ranges: actual salinity, natural seawater salinity, percentage salinity
6. Linear and nonlinear temperature compensation
HANNA HANNA HI4521 Multi Parameter Water Quality Analyzer from Italy Product Parameters:
pH |
measuring range |
-2.0-20.0 pH;-2.00-20.00 pH; -2.000-20.000 pH |
|
resolution |
0.1 pH;0.01 pH; 0.001 pH |
||
accuracy |
±0.1 pH;±0.01 pH;±0.002 pH |
||
Calibration Mode |
Automatic 5-point calibration, with 8 built-in calibration points (pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) and 5 user-defined calibration points |
||
redox |
measuring range |
±2000.0 mV |
|
resolution |
0.1 mV |
||
accuracy |
±0.2 mV |
||
Calibration Mode |
Acidity automatic calibration, built-in 8 standard calibration points and 5 user-defined calibration points; |
||
conductivity |
measuring range |
0.000-9.999 µS/cm; 10.00-99.99 µS/cm; 100.0-999.9 µS/cm; 1.000-9.999 mS/cm; 10.00-99.99 mS/cm; 100.0-999.9 mS/cm; 1000 mS/cm with seven measurement ranges |
|
resolution |
0.001 µS/cm; 0.01 µS/cm; 0.1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm |
||
accuracy |
± 1% of the reading (± 0.01 µ S/cm) |
||
Calibration Mode |
Automatically identify built-in calibration points or use user-defined calibration points for calibration |
||
resistivity |
measuring range |
Seven measurement ranges: 1.00-99.99 Ω• cm; 100.0-99.99 Ω• cm; 1.000-9.999 k Ω• cm; 10.00-99.99 k Ω• cm; 100.0-99.99 k Ω• cm; 1.00-99.99 M Ω• cm; 10.0-100.0 M Ω• cm |
|
resolution |
0.01 Ω•cm;0.1 Ω•cm;0.001 kΩ•cm;0.01 kΩ•cm;0.1 kΩ•cm;0.01 MΩ•cm;0.1 MΩ•cm |
||
accuracy |
± 2% of the reading (± 1 Ω• cm) |
||
temperature compensation |
Conductivity compensation is: linear or nonlinear automatic temperature compensation |
||
TDS |
measuring range |
0.000-9.999 ppm; 10.00-99.99 ppm; 100.0-999.9 ppm; 1.000-9.999 ppt; 10.00-99.99 ppt; 100.0-400.0 ppt six measurement ranges |
|
resolution |
0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt |
||
accuracy |
± 1% or ± 0.01 ppm of reading |
||
TDS/EC conversion coefficient |
0.40-1.00 |
||
salinity |
measuring range |
Actual salinity: 0.00-42.00; Salinity of seawater: 0.00-80.00 ppt; Percentage salinity: 0.0-400.0% |
|
resolution |
0.01; 0.1% |
||
accuracy |
± 1% of the reading |
||
Calibration Mode |
Percentage salinity single point calibration |
||
temperature |
measuring range |
-20.0-120℃; -4.0-248.0°F;253.15-393.15K |
|
resolution |
0.1℃; 0.1°F;0.1K |
||
accuracy |
±0.2℃; ±0.4°F;±0.2K |
||
Calibration Mode |
3-point calibration |
||
Basic indicators |
measurement channel |
One pH/mV/ISE channel and one EC channel |
|
End point locking |
Automatic endpoint locking |
||
Data Storage |
Automatic or manual storage, 10 sets, 5000 data per set |
||
Data interface |
USB/RS232 data interface |
||
screen display |
240 × 320 dot matrix color display screen, with functions such as on-screen assistance and user confirmation |
||
Power Mode |
AC220/12VDC power adapter |
||
Size/Weight |
Host: 159 × 230 × 93 mm/800 g |
||
Choosing power distribution is very important |
Acidity/Redox |
HI1131B can be filled with glass composite acidity and is used for routine solution measurement in the laboratory |
|
HI1200B non fillable plastic composite acidity meter, used for laboratory and on-site routine solution measurement |
|||
HI1300B non fillable plastic composite acidity meter, used for laboratory and on-site pure water measurement |
|||
HI3131B can be filled with glass ORP electrode, applied for laboratory redox potential measurement |
|||
EC/TDS/NaCl |
HI76312 conductivity/resistivity/TDS/salinity four ring electrode, applied to laboratory EC/TDS/NaCl measurement |
||
temperature |
HI7662-T high-precision temperature probe |
Product configuration of HANNA HANNA HI4521 multi parameter water quality analyzer from Italy:
Standard configuration |
HI4521 |
Host, HI1131B refillable glass composite acidity sensor (BNC interface, wire length: 1 meter), HI7071S customized special electrolyte filling solution (30ml), HI76312 built-in temperature sensor four ring EC/TDS electrolyte, HI7662T stainless steel temperature probe (wire length: 1 meter), HI70004 (pH4.01, 20mL), HI70007 (pH7.01, 20mL) acidity standard buffer solution, HI76404N customized special electrolyte bracket, HI710006/8 power adapter, Chinese English user manual, HE721004 customized special instrument carrying case |
HI4521P |
Host, HI1131B refillable glass composite acidity sensor, HI7071S filling solution, HI76312 built-in temperature sensor with four rings EC/TDS, HI7662-T stainless steel temperature probe, randomly bagged acidity standard buffer solution, HI76404N special bracket for electricity, Chinese and English user manual, HE721004 customized special instrument carrying case |
|
HI4521B/C |
Host, HI1131B/C glass composite acidity sensor, HI76312 built-in temperature sensor with four ring EC/TDS sensor, HI7662-T stainless steel temperature probe, randomly packaged acidity standard buffer solution, HI76404N specialized bracket for acidity sensor, Chinese and English user manual, HE721004 customized special instrument carrying case |
|
HI4521C |
Host, HI1230B/C plastic composite acidity sensor (BNC interface, wire length: 1 meter), HI76312 built-in temperature sensor four ring EC/TDS sensor, HI7662T stainless steel temperature probe (wire length: 1 meter), HI70004 (pH4.01, 20mL), HI70007 (pH7.01, 20mL) acidity standard buffer solution, HI76404N customized special electrical bracket, HI710006/8 power adapter, Chinese English user manual, HE721004 customized special instrument carrying case |
|
HI4521PC |
Host, HI1230B plastic composite acidity sensor, HI76312 built-in temperature sensor with four rings of EC/TDS sensor, HI7662-T stainless steel temperature probe, randomly bagged acidity standard buffer solution, HI76404N special bracket for acidity sensor, Chinese and English user manual, HE721004 customized special instrument carrying case |
|
optional accessories | ||
HI1043 |
Fillable glass composite with high acidity and electrical conductivity |
|
HI1053 |
Cone shaped head can be filled with glass composite acidity electricity |
|
HI1083 |
Ultra fine round glass composite with high acidity and electrical conductivity |
|
HI1131 |
Fillable glass composite with high acidity and electrical conductivity |
|
HI1230 |
Plastic composite with high acidity and electrical conductivity |
|
HI3230 |
Plastic composite redox charge |
|
HI76312 |
Built in temperature sensor with multiple parameters and four ring electrical system |
|
HI7662 |
Stainless steel temperature probe |
|
HI54710 |
Laboratory grade acidity calibration group |
|
HI5004 |
Laboratory Test Certificate Acidity Standard Buffer Solution |
|
HI5007 |
Laboratory Test Certificate Acidity Standard Buffer Solution |
|
HI5010 |
Laboratory Test Certificate Acidity Standard Buffer Solution |
|
HI7020 |
Redox standard buffer solution |
|
HI7021 |
Redox standard buffer solution |
|
HI7022 |
Redox standard buffer solution |
|
HI7091 |
Redox standard buffer solution |
|
HI7092 |
Redox standard buffer solution |
|
HI7071 |
Conventional electric filling fluid |
|
HI7061 |
Conventional electric cleaning solution |
|
HI70300 |
Electric preservation solution |
|
HI920010 |
5-9-pin RS232 data transmission cable |
|
HI92000 |
Data processing management software |
|
HI920014 |
data transmission line |
|
prompt |
The HI4521 standard configuration only includes EC/TDS/NaCl batteries and does not include acidity batteries, or according to the corresponding model standard configuration price description |
|