E-mail
gzbzyq@126.com
-
Phone
18665097176
-
Address
306, Building C, No. 10 Shihuan Road, Huanxi, Tianhe District, Guangzhou City
Guangzhou Beize Instrument Technology Co., Ltd
gzbzyq@126.com
18665097176
306, Building C, No. 10 Shihuan Road, Huanxi, Tianhe District, Guangzhou City
GPR-1200MSPortable trace oxygen analyzerRange: 0-1/10/1000ppm, accuracy: 1% of the range;Trace oxygen analyzerGPR-1200MS Automatic/Manual Range Adjustment American AIIoxygen analyzerMeasurement: Inert gas (O2 content 10pppb~1000ppm); He; H2 hydrogen, N2 nitrogen; mixed gases, hydrocarbons, acidic gases, natural gas, coal gas.
GPR-1200MSPortable trace oxygen analyzerTechnical Specifications:
Accuracy:<1% of full scale
Range: 0-1, 0-100, 0-100, 0-1000ppm adjustable
Application: Analyze the oxygen content in inert gases, hydrocarbon gases, He, H2, and CO2 from 10ppb-1000ppm.
Certification: CE, Intrinsic Safety Type
Regional level: intrinsically safe design, suitable for Class I, Div.I, Goups A, B, C, D
Alarm: None
Calibration: Is the door of the garment perfect for a home? Certified standard gases with a range of 80% or higher
Compensation: Temperature
Interface: 1/8 "connector
Control: Range selection switch, waterproof key, calibration and system functions
Display: 2.75 "× 1.375"; Resolution: 0.01ppm; Real time display of temperature and pressure
Appearance: NEMA 4X, 8.6 * 9 * 3 "12 lbs
Traffic impact: 0.25-2.5L/m, recommended traffic: 1L/M
LED display light: low battery and charging mode
Linear:>0.995 exceeds all ranges
Pressure: Injection 5-30psig; Evacuation - Atmospheric pressure
Power supply: rechargeable battery, single battery can last for 60 days, pump on for 1 day
Recovery time: Exposure to air for 60 seconds and recovery to 10ppm with nitrogen gas takes 20 minutes
Response time: 90% full scale is 10 seconds
Sampling system: flow control and sample gas/bypass valve, flow indication
Sensitivity:<0.5% of full scale
Sensor model: GPR-12-2000MS, maintenance free
Sensor lifespan: 24 months, 25 ℃, average O2<100ppm
Output: 0-1V
Temperature range: 5-45 ℃
Warranty period: 12 months
Sample gas contact part: stainless steel
Optional items:
Built in sampling pump - universal or intrinsic safety type
Portable case
Injection filter
Other accessories and consumables:
GPR-12-2000MSoxygen sensor
XLT-12-333 Acid Gas Oxygen Sensor
oxygen analyzerBattery A2244
A-2590 instrument with suction pump rechargeable battery
PWRS-1003 9V charger (220V AC)
A-1004 Sensor Cover
LCDLCD display MTR-1001
A-1095M main PCBboard
A-2166 intermittent working vacuum pump
oxygen analyzerBattery A1163
A-2166-4 consecutiveWorking vacuum pump