phoenixnanotomm
——Suitable for fields such as materials science, sensing/electrical engineering, measurement technology, geology/biology, etc
Phoenix Nanotom is a nanoCT system used for scientific and industrial computed tomography (microCT and nanoCT) and three-dimensional measurements of a wide sample range. With its designed 180 kV/15 watt high-power nanofocus X-ray tube with internal cooling and temperature stable digital detector, the system achieves spatial and comparative resolution for a wide range of samples and applications - from small biological and geological specimens to medium-sized industrial components such as injection ports or injection molded plastic parts - as well as metal inlays. The fully automated execution, reproduction, and analysis process of CT scanning ensures its usability as well as fast and reliable CT results. Once scanned, full 3D CT information can provide many possibilities for analysis, such as non-destructive visualization of slices, arbitrary cross-sectional views, or automatic pore analysis. It is possible to scan the entire geometric shape of an object, perform precise and reproducible 3D measurements of complex objects, and automatically generate first article inspection records within one hour.
feature
Main functions
Higher image quality from temperature stable digital GEDXR detector (3072x 2400 pixels) for high dynamic range>10000:1
The new open 180 kV/15 watt high-power nanofocus X-ray tube has a detail detection capability of up to 200 nanometers and internal cooling - which is better for long-term stability
The measurement beam used for 3D measurement applications includes: a temperature stable cabinet; High precision direct measurement system; Vibration isolation of the operator; Diamond | Window; Two calibration objectives; Phoenixdatos | x2.0 software package "Click&Measure CT" and 3D "Measure"
Customer benefits
Wide sample range of spatial and comparative resolution - from small materials to medium-sized plastic samples containing 3 orders of magnitude (0.25mm to 250mm sample size and 3kg/6.6lb sample weight)
Better 3D measurement package for stable acquisition conditions, fast reconstruction within minutes, and reproducible measurement results
Better usability comes from system design and advanced phoenixdatos | x2.0CT software
Diamond shaped windows can achieve extremely high focal stability and perform data acquisition up to twice as fast with the same level of high image quality
application
![]() |
3D computed tomography The application of industrial X-ray 3D computed tomography (microCT and nanoCT) is for the detection and 3D measurement of metal and plastic castings. However, the high-resolution X-ray technology of Phoenix | X-rays has opened up new applications in many fields, such as sensor technology, electronics, materials science, and many other natural sciences. NanoCT for SMD sensor, size 0805 (2.0 mm x 1.2 mm) The 3D X-ray image shows the internal coils behind the back cover. In any conventional X-ray, the layer panels overlap, but nanoCT successfully displays objects layer by layer. |
![]() |
measurement
The figure shows the CAD difference analysis and measurement of three devices on the cylinder head |
![]() |
Materials Science
High resolution computed tomography (microCT and nanoCT) is used for detecting materials, composite materials, sintered materials, and ceramics, but it is also used for analyzing geological or biological samples. The material distribution, porosity, and cracks are visible in three dimensions at a microscopic resolution. NanoCT of glass fiber composite material: The fiber orientation of the fiber felt (blue) and the matrix resin (orange) will be displayed. On the right: The voids inside the resin will appear as dark cavities. On the left: The resin has gradually disappeared to better visualize the fiber felt, and the individual fibers inside the felt are visible. |
![]() |
Plastic Engineering NanoCT of glass fiber reinforced plastic samples: The arrangement and distribution of aggregates of glass fibers and mineral fillers (purple) are clearly visible. The fibers are approximately 10 microns wide. |
![]() |
Sensors and Electrical Engineering NanoCT displays the welding joints of CSP components. The three-dimensional shape of the welded joint is approximately 400 microns in diameter, with clear and visible gap distribution. Inside the welding joint, different eutectic solder phases are visible. |
![]() |
Geological/Biological Sciences
Segmented pores in carbonates (ø 2mm) |
| Maximum tube voltage | 180 kV |
|---|---|
| maximum power | 15 watts |
| Detail detection capability | Up to 200nm (0.2 μ m) |
| Focal distance measurement | 150mm to 600mm |
| Minimum voxel size | < 300nm (0.3μm) |
| Geometric magnification (3D) | 1.5 times to 300 times |
| Maximum target size (height x diameter) | 250mm x 240mm/9.84 'x 9.45' |
| Maximum object weight | 3 kg/6.6 pounds |
| Image Chain | 7-megapixel flat panel digital detector array |
| 2D X-ray imaging | No |
| 3D computed tomography | can |
| Advanced surface extraction | Sure (optional) |
| CAD comparison+dimension measurement | Sure (optional) |
| System size | (1980 x 1600 x 900 millimeters), (78 "x 63" x 35.4 ") |
| System weight | 1900 kg/4189 pounds |
| Radiation safety |
-Fully radiation resistant safety cabinet, in accordance with German ROV (Attachment 2 nr. 3) and American performance standard 21 CFR 1020.40 (Cabinet X-ray System) -Emission limit for exposure<1 μ Sv/h, measured from a distance of 10 centimeters from an accessible surface |